- Electricity - Electronics >
- Switch and Relay >
- IEC contactor
IEC contactors
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 450 A
Load voltage: 7.2 V - 15 V
... distribution systems and ensuring end-to-end protection for your system operation Compact, energy-efficient 3TM vacuum contactors are flexible to use and are suited for all relevant areas in medium-voltage power distribution, for rated ...
Primary current: 20, 16, 11.5 A
Load voltage: 230 V
... Main contacts - 3 Max. add-on aux. contacts - 4 Packing format - Multi pack Product group - Contactors and motor starters Product Name Description - Contactor Quantity per packing format - 5 pc REACH Candidate List ...
Primary current: 350 A - 500 A
Load voltage: 0 V - 1,500 V
... Efficient and compact single-pole DC NO contactors up to 1,500 volts switching voltage, continuous currents up to 500 amps and high inrush and short-time currents for most diverse e-mobility applications. The contactors ...
Schaltbau GmbH
Primary current: 9 A - 225 A
Load voltage: 24 V - 600 V
... Developed according to IEC 60947 and UL 508 international standards, the new WEG CWB line of contactors meets the requirements of a wide range of industrial applications worldwide. Compact Solution The small dimensions ...
WEG Gear Systems GmbH
Primary current: 9 A - 170 A
Load voltage: 0 V - 690 V
... The UEC1-09C...170C AC contactors range to a rated current of 9...170A under the utilization category AC-3 and can be driven by both 50Hz and 60Hz. They can be combined with a thermal overload relay. Product Features - Designed under ...
Xiamen Hongfa Electroacoustic Co.,Ltd.
Primary current: 0.15 A - 7.6 A
Load voltage: 48 V - 600 V
... Solicon DRC3 Series are Solid State Contactors intended for frequently switching on and off three phase loads up to 5 HP, 600 VAC 7.6 Amps. They are available in both contactor versions DRC3P and reversing contactor ...
Primary current: 0.15 A - 20 A
Load voltage: 48 V - 600 V
... The DRH Series is a family of compact DIN Rail Mount, IEC standard based Solid State Contactors with ratings up to 20 Amps per channel at 600 VAC. The DRH Series is ideal for heating applications up to 20A per phase, ...
Primary current: 25 A
Load voltage: 220 V
DIGITAL ELECTRIC
Primary current: 25 A
Load voltage: 240 V
DIGITAL ELECTRIC
Primary current: 40 A
Load voltage: 220 V
DIGITAL ELECTRIC
Primary current: 25 A
Load voltage: 440, 600, 380, 415, 220 V
... GSC1-09/3-170/3 Series 3P AC Contactor For remote connection and disconnect circuit, and can be combined with the appropriate thermal overload relay to form an electromagnetic starter, in order to protect the possible overload circuit.(Suitable ...
Tianshui 213 Electrical Apparatus Group CO.,LTD.
Primary current: 75, 50 A
Load voltage: 24 V - 520 V
... The Three phase ZeroCross Solid State Contactor is specially developed for all kinds of loads. It has a latest High Efficiency Back to back thyristors on output with TMS2 technology for a long service time of 24 to 520VAC 50A I2t > ...
Primary current: 20 A
Load voltage: 440 V
... intended to be installed on standard mounting rails with 35 mm width (EN 50022). The contactors can be leaded by a lead cover available in an auxiliary contactor block RH 11. It has a relatively silent operation, long ...
ETI
Primary current: 160 A - 350 A
Load voltage: 24 V - 500 V
... qty. of packs per order - 1 Package dimensions [mm] - Volume [cm³] - 8217.715 BF160T4E230 Type of coil: AC/DC coil IEC operating current and power Ie (AC3) 400V [A/Kw]: 230A /110Kw UL/CSA horsepower ratings 480V [HP]: 150 Type ...
Primary current: 9 A
Load voltage: 24 V
... sizes to fit respective contactors of given rated current. 5-Year limited warranty. Certifications • UL 508 Listed File Number E3553866 / UL 60947-1 and 60947-4-1 • Certified for Canada according to CSA C22.2 No. 14 • IEC/EN ...
... 4pole contactors GH16 series for resistive loads AC‐1 utilization category. ...
... According to the CEI 17-3 standard, a contactor or remote switch is a mechanical manoeuvring device, generally designed to perform a high number of operations. It is also known as a monostable device because it has a single idle position, ...
Primary current: 16, 63 A
Load voltage: 24 V
... device etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The Contactor is produced according ...
Primary current: 6 A - 20 A
Load voltage: 380 V
... Product Item : S-P06 S Specification : standard:GB 14048.4、 IEC 60947-4-1、EN 60947-4-1、DIN VDE 0660 Rated insulation voltage:660V Coil control voltage:AC12V~440V/50Hz、AC12V~480V/60Hz Electrical Life/AC3:1.2 million times Mechanical ...
Primary current: 80 A - 1,300 A
Load voltage: 600, 750 V
... mounted contactors. These contactors have been designed starting from the N Series electric arc management concept, grafted on the light and compact structure of a rail unit, developed around the control electromagnet. The ...
Microelettrica
Primary current: 7 A - 630 A
... TECO produces magnetic contactor (7-630A), with whole series conforming to IEC standards, including cases which employs UL-approved fire-retardant V-0 industrial plastic materials, with high fire-proof function, capable ...
Primary current: 9 A - 630 A
Load voltage: 24 V - 415 V
... Low voltage contactors are produced according to IEC/EN 60947-4-1. They are used remotely to control and protect (in combination with thermal O/L Relays) electrical motors and other electrical Loads such as lamps,capacitors, ...
SIGMA ELEKTRIK
Primary current: 9 A - 330 A
Load voltage: 380, 660, 1,000 V
... Application CJX2 series AC contactors are suitable for frequency 50/60Hz,rated insulation voltage up to 10000V, rated operation current 9~330A under AC-3 duty.lt is mainly used for making/breaking electric circuits ata long distance ...
Load voltage: 230 V
... Capacitor Switching Contactor 25kVAR, 230V AC Coil Capacitor Switching Contactors MC-K • 12.5kVar up to 100kVar • For use with reactive or non-reactive capacitor banks • DIN rail mounting to 100kVar • Early ...
IMO Precision Controls Limited
Primary current: 9, 12, 5 A
Load voltage: 690, 600 V
... CKDC1 contactors are designed to be used for commercial lightting, industrial equipement, compact space, with smaller volume required by IEC product. 35 mm DIN-Rail installed or panel installed AC or DC coil control ...
COMESTERO SISTEMI
Primary current: 6, 20 A
Load voltage: 195.5 V - 253 V
Primary current: 20 A - 110 A
Load voltage: 110 V - 660 V
... produced by operation. Contactor can also be attached with building block type auxiliary contact group, air delay contact, mechanical interlock mechanism, etc. accessories, to be composed into delay contactor, directional ...
PEOPLE ELE. APPLIANCE GROUP CO., LTD.
... Motor contactor Product specification: Most ZIEHL-ABEGG external rotor motors are fitted with thermostatic switches (TB). Explosion-proof external rotor motors have a temperature sensor (TP). A temperature sensor (TP) is also integrated ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group