- Metrology - Laboratory >
- Analytical Instrumentation >
- Infrared analyzer
Infrared analyzers
... The TGA200A Trace-Gas Analyser measures trace-gas concentrations in an air sample using tunable-diode laser absorption spectroscopy (TDLAS). This technique provides high sensitivity, speed, and selectivity. Its simple design allows it ...
... Measurement Principle: The analyzer utilizes the wet oxidation NDIR (Non-Dispersive Infrared) detection principle. In this method, the water sample is acidified to remove inorganic carbon. Then, the organic ...
... The equipment uses imported NDIR non-spectroscopy infrared and ECD electrochemical technology, which is mainly used to measure the volume concentration of CH4, CO2, H2S, O2, H2, CO in biogas. The product has high measurement ...
Hubei Fangyuan Environmental Protection Science & Technology Co., Ltd.
... AM505 Carbon Dioxide (CO2) Analyser employs Gas Filter Correlation Infrared Absorption Method to measure low concentrations of CO2. This method is based on Lambert-Beer's law and involves comparing the ...
ORTHODYNE SA
... and CH4, etc. -It adopts NDIR detection principle and has high precision and good stability. -One and three gas contents can be detected depending on situations. Specifications: Model: AGA1000 Measure Principle: NDIR Target ...
Nanjing AIYI Technologies Co., Ltd.
... using the method of selective radiation absorption in the UV and IR range (NDUV / NDIR) is an established method for determining concentrations in complex gas mixtures. The BINOS NG Gas Analyser uses state-of-the-art ...
... GY1000 Infrared Online Moisture Analyzer is a real-time online measurement system for measuring the moisture content of substances developed by using the absorption principle of moisture in the near- infrared ...
... Paper / Pulp / Glass / Ceramics / Maritime / Boiler MEASURED COMPONENT NOx, SO2, CO, CO2, O2 DSM-X FEATURES 1. Multi- analyzer integrating UV, NDIR, and Zirconia measurement methods into a single product, allowing simultanceous ...
DXG Ltd.
... The EnergyTech 203 O2 and CO analyser is the ideal equipment for fine tuning the air / combustible proportions in a way to improve process efficiency without compromising safety. The EnergyTech 203 O2 and CO analyser ...
... It includes sound & light alarm, vibration alarm, display screen visual alarm.Alarm types include: concentration alarm, under-voltage alarm, and failure alarm. Multiple alarm mode settings: low alarm, high alarm, interval alarm, and weighted average alarm. Graphical ...
Beijing Zetron Technology Co., Ltd
... ProCeas® GENERAL is a complete pre-calibrated multi-component (CH4 , CO, CO2, H2, H2O, HCI, HCN, HF, N2O, NH3, O2) laser infrared spectrometer for gases analysis. ...
AP2E
... Application: Sundy SDCHN536 Carbon Hydrogen & Nitrogen Analyzer can be used to determine the carbon, hydrogen and nitrogen content in coal,coke,food,solid wastes,soil,fertilizer,etc in the fields of power plant,coal mine,metallurgy,petrochemical ...
Hunan Sundy Science and Technology Co.,Ltd
... multi-channel NDIR measuring bench for up to 6 gases custom configuration wide range of gases and measuring ranges Outputs RS232 and analogue 4-20mA (Option) The NDIR7000 is a universal configurable NDIR ...
Saxon Junkalor GmbH
... task oriented menu - Data logging, site management and data export to SD card Portable Biogas Analyser The RASI 700 BIO is a portable biogas analyser ideal for measuring gas in landfill, biogas, and water water ...
Eurotron Instruments UK ltd
... Get full control of your cocoa processing and chocolate manufacturing processes with the NIRS™ DS2500 analyser. Ensure the quality of incoming raw materials, optimise the critical production steps and check final product quality. Value Control raw ...
Foss Analytical
... : The tailor-made new model platinum infrared light source has lasting caloricity and efficient spectral property. Analysis cell: The gilded carbon & sulfur analysis cell is fit with the high precision TSC infrared detector ...
... Possible Techniques: FTIR: Fourier Transform Infrared Spectroscopy: Measurement of basic and trace gas components until ppm range (for example H2O, CO2, CO, H2S...). Polar Molecules are necessary. Raman-Spectroscopy: Measurement ...
... example following contamination. LetzTOC: INFRARED SPECTROSCOPY BY NDIR DETECTION LetzTOC uses UV light to oxidise organic substances to CO2, which is then measured by infrared spectroscopy. The use ...
... individually defined measurement cycles. The following reasons speak for the use of the GMC Biogas 08 biogas analyzer from Bieler + Lang: • Double infrared measuring bench for CH4 and CO2 • H2S sensor in separate ...
... Introducing the MIRA Pico portable middle infrared laser-based gas analyzers from AerisTechnologies, Inc. MIRA gas analyzers utilize simple and robust direct absorption spectroscopy using high resolution ...
... be enhanced with additional dosage of reagent (persulfate). By using the NDIR detector the uniTOC gives precise results in applications of ground water to ultrapure water. The NDIR detector is absolutely selective to ...
... Optically measure the SS concentration and MLSS concentration of the sample water continuously using the infrared scattering light measuring method. The detector is made of small and lightweight stainless steel, safe and easy to operate ...
... flue gas emission analyser for H2-analysis at industrial sites Precise and very stable offset measuring technique by means of non dispersive infrared (NDIR) technique, for enhanced long time measurements ...
MRU – Messgeräte für Rauchgase und Umweltschutz
... Feasa's Multichannel Automatic Infrared LED Analyser solution for fast Wavelength & Intensity measurement The IR LED Analyser has a unique fiber which has been specially selected and ...
... The new PULSAR NDIR Multi-gas analyser from Signal Group has been upgraded to provide the company’s best ever performance specification. With ultra-low drift it is ideal for low range applications and high accuracy measurement. ...
... The IPOS2 O2/CO2 gas analyser is a versatile analyser that can be either portable or bench-mounted. The only gas analyser with blocked circuit detection, the IPOS2 is the only one capable of offering ...
Anéolia
... HK-K104 Carbon Dioxide Analyzer OverView HK-K104 Carbon Dioxide Analyzer adopts NDIR working principle. Itcan be used to analyze gases such as carbon dioxide (CO2), methane (CH4), carbon monoxide (CO), ...
... quick field change of the sensors. The infra-red detector can be cleaned in the field if necessary by the on-site technician. Environmental management packages are available to allow operation of th analyzer outdoors ...
... individual compound: • CO ppm V GfX infrared gas analyzer • CO2 ppm v GfX infrared gas analyzer • O2 Vol% Pm paramagnetic gas analyzer (with atmospheric pressure compensation) • ...
DKS GmbH
... Teledyne’s Series 7500 Infrared (IR) Gas Analyzer is capable of detecting up to three individual IR absorbing components (i.e. CO, CO2, CH4, SO2) on a continuous basis. Packaged in either a 19” rack mount ...
Steam Equipments
... include H2O, SO2, HF, O2 & CF4. A number of configurations are available to suit application requirements. Once connected the analyser samples gas automatically, allowing safe operation. A vacuum purge cycle & gas storage system ensures ...
Cambridge Sensotec
... The Model HC-404 is a self contained, fixed wavelength infrared spectrometer designed for rapid accurate analysis of total petroleum hydrocarbons in water, soil and sludge samples. Perfect for ASTM method D 7066-04, EPA method 418.1 ...
... Analyzer systems for chemical and oil and gas plants Products and systems Analyzers shelters. Analyzers Cabins. Analyzers Racks. Sampling probe. Pre-conditioning. Sample transport ...
... flour, without requiring sample preparation. MININFRA 2000T transilluminates the sample on a large surface and measures its infrared spectra. The embedded computer calculates the values of the sample components. Up to 6 components can ...
ISOELECTRIC
... GASERA ONE is a photoacoustic multi-gas analyzer platform that can be configured to a wide variety of research and industrial applications. It combines the best of both worlds in the detector and the light source sides. The unmatched ...
The unit for determining water content is a precise tabletop measuring unit that measures low water content in solids. The accuracy of the test procedure combined with a relatively high sample weight enables even the smallest levels of moisture to be ...
... Communication Protocol Ethernet with Modbus TCP; RS 485 / 232C with Modbus RTU; 2 USB ports Features Up to five component gas analyzer featuring NDIR/UV/VIS photometer, paramagnetic and electrochemical O2, thermal conductivity, and ...
... parameters. You can choose to use one or more single analyzers or a complete and integrated measurement and recording system. In-situ solutions without sampling and treatment of the sample gas Infrared and zirconium ...
... O2- and O2/CO2-gas analyser for MAP-packages Cordless handheld oxygen or combined oxygen and carbon dioxide analyser for checking modified atmospheres in food packs. The ideal instrument for portable, faster and accurate ...
WITT-Gasetechnik
... High-quality gas analyser for quality control of Modified Atmosphere Packaging. The OXYPAD is a mobile desktop unit with an innovative design: a full-fledged desktop analyser with 7″ touch-screen, and it’s truly mobile ...
WITT-Gasetechnik
... O2- and O2/CO2- headspace gas analyser for MAP-packages, standard version ideal for quality control fast and precise sample headspace testing minimum sample gas requirement O2 value is displayed in 0,01% steps ...
WITT-Gasetechnik
... principle of infrared absorption spectroscopy. As the spectral signature of certain constituents is known, by measuring the absorption at certain wave-lengths, it is possible to determine the content of the constituent ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.