- Metrology - Laboratory >
- Laboratory Equipment >
- Laboratory sieve shaker
Laboratory sieve shakers
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Max. sample weight: 0.1 g - 2,000 g
Sieve diameter: 100, 203, 200 mm
Number of sieves: 16, 10 unit
... performance Vibratory Sieve Shaker A-3 PRO offers everything you need for fast determination of quantitative particle size distribution in the laboratory. As a shaking sieve system with ...
Max. sample weight: 20 g - 2,000 g
Sieve diameter: 100, 200, 203 mm
Number of sieves: 10, 16 unit
... causes the sieves to oscillate in a vertical direction. The material to be sieved is periodically propelled upward off the sieve fabric and forced through the mesh of the attached test sieve as it falls ...
Max. sample weight: 3 kg
Sieve diameter: 100, 200, 203 mm
Measurement range: 20 µm - 25,000 µm
... Vibratory Sieve Shakers There are many applications for which wet sieving is the best solution, e.g. when the material to be tested is a suspension or when a very fine sample (< 45 μm) that tends to agglomerate needs ...
Retsch GmbH
Max. sample weight: 6 kg
Sieve diameter: 100, 200, 203, 305, 315 mm
Measurement range: 20 µm - 40,000 µm
... The AS 300 model has all the benefits of the AS 200 control but is designed for test sieves with a diameter up to 315 mm, providing a sieve surface which is approximately 2.5 times larger. Therefore, the AS 300 is able ...
Retsch GmbH
Max. sample weight: 25 kg
Sieve diameter: 400, 450 mm
Measurement range: 25 µm - 125,000 µm
... With the Vibratory Sieve Shaker AS 450 control RETSCH have designed their first 3-D shaker for 400 mm and 450 mm sieves. It can be used for dry and wet sieving of sample amounts of up ...
Retsch GmbH
... Small and compact digital electromagnetic sieve for particle size testing ...
Max. sample weight: 15 kg
Sieve diameter: 450 mm
... the EML series; with bulk material weights of up to 15 kg, it also offers the largest feed capacity and is ideal for test sieves with diameters of up to 450 mm. •Individually adjustable amplitudes •Wet and dry sieving •Separate ...
NEXOPART GmbH & Co. KG
... system (no electrical power required). > Specialized in safety sieving. > Sieve shaker for small-scale production. > Quick sieve changeover. > Easy cleaning of the sieves and the ...
... worldwide unique technology especially for exciting common laboratory ring sieves (according to DIN ISO 3310/1 or ASTM E 11-95) with diameters of 200mm or 8 inch. A ring sonotrode that fits the sieve ...
Max. sample weight: 0 kg - 3 kg
Sieve diameter: 200 mm
Number of sieves: 8 unit - 16 unit
... and engineered shaker. It incorporates many features usually found only on larger, more expensive models. It is ideal for the use in laboratories and plants since it is compact and genuinely portable (weighing only ...
Endecotts
... particular by the following features: Display of vibration amplitude, reading of weighing data via Bluetooth, evaluation of sieve analyses with graphic display as line or RRSB diagram, Standard Operating Procedures (SOP), calling up the ...
Number of sieves: 12, 8 unit
... with timer. • The shaker can be completed with the Noise reduction cabinet recommended for use in the CE countries and with the Wet sieving attachment for washing fine materials through the sieves without any loss of ...
Max. sample weight: 28 kg
Sieve diameter: 75 mm - 200 mm
... process can be done down to 20 μm. The optimum filling level for each test sieve depends on the sieve frame diameter (75/100/150/200/203) and in relation of the mesh size of the test sieve. Ambient ...
Max. sample weight: 3 kg
Sieve diameter: 150, 315, 200, 300, 100 mm
Number of sieves: 8, 6 unit
... 200 SQ Analogue is built with a stable electromagnetic motor. 200 SQ Analogue is suitable for laboratory use. 300,315, 450 SQ Analogue models are motorized shakers and are ideal for heavy-duty. ...
Max. sample weight: 20 kg
Sieve diameter: 800 mm
... to be used as a sieving equipment for particle size tests on any product. Its frame can accommodate up to eight small sieves, plus the bottom piece and the cover. The following is a brief list of the sieving machine's main features: it ...
... Sieve Shaker SQ Analogue CRT-SVSK-SQ is a economical high quality sieve shaker, ideally suited for laboratories where aesthetic appearance, economy and reliability go ...
Cooper Research Technology
Max. sample weight: 10 g - 5,000 g
Sieve diameter: 400, 300, 200 mm
Measurement range: 20 µm - 10,000 µm
... Digital Laboratory Sieve Shaker KTL Available for 200 + 300 + 400 mm diameter Laboratory screens For a stack of up to 8 or 16 standard 200 mm analysis screens Unit ready to operate Cover ...
... to the bottom. All our manual sieve shakers deliver consistent, repeatable results that are substantially more reproducible than hand sieving. Our range of manual sieve shakers ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group