- Electricity - Electronics >
- Switch and Relay >
- Manual disconnect switch
Manual disconnect switches
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 40 A - 2,000 A
VAC: 690 V
Switch-Disconnectors Dumeco DMV Type DMV, 160 - 2000 A, 690 V AC, switch-disconnectors have excellent short-circuit making capacities, due to its parallel knife contacts with double break per phase. High ...
Eaton
Primary current: 250, 400 A
VDC: 500 V
When trying to isolate circuits or repair systems, the LS60250 dc disconnect switch quickly breaks or resumes the flow of current safely to prevent shock hazards. It has a total voltage rating of 500 ...
Everything you need to make your application more efficient than ever: Commute easily power sources thanks to a changeover mechanism. Provide a real flexibility to fit with all type of installations thanks to a large choice of Pole units, ...
Primary current: 2,000 A
VAC: 126, 145 kV
Center break disconnector with smaller footprint and high reliability Hitachi Energy’s DDHV – ‘V’ type center break disconnector is a compact, reliable and easy-to operate substation equipment. Suitable ...
Primary current: 3,150 A
VAC: 800 kV
... and minimal maintenance The horizontal knee disconnector requires the smallest spaces in both horizontal and vertical directions, suitable for substation with small installation area. The DDK800 disconnector ...
Primary current: 5,000 A
VAC: 145, 245, 420, 550 kV
... Ice breaking capacity Applications The appropriate use of GW54 pantograph disconnector is when busbars are arranged at two different levels. The GW54 pantograph disconnector is suitable for installation ...
Primary current: 30 A - 1,200 A
... products, these switches are also engineered to have the smallest footprint. The modular design allows placement of the handle anywhere amongst the poles. The fuse doors cannot open when the switch is ...
Primary current: 800 A
VDC: 750 V
The battery switch is used to connect and disconnect the DC power from the battery during maintenance of the battery box with a high level of safety. The TCMB line covers a current range up to 800A ...
Primary current: 16 A - 160 A
VAC: 110 V - 690 V
... easily transformed from a load break switch to a changeover switch, offering a highly innovative modular solution for numerous applications. A wide range of accessories A single standard 3 pole load ...
SOCOMEC
Primary current: 25 A - 100 A
... opening amplitude and connection terminals are amply sized. - Degree of protection: up to IP 66 - For 25A to 100A size switches - Cable entries with pre-formed knockouts - Tamper-proof cover with padlockable handle - ...
Primary current: 25 A - 100 A
... opening amplitude and connection terminals are amply sized. - Degree of protection: up to IP 66 - For 25A to 100A size switches - Cable entries with pre-formed knockouts - Tamper-proof cover with padlockable handle - ...
Primary current: 25 A - 100 A
... opening amplitude and connection terminals are amply sized. - Degree of protection: up to IP 66 - For 25A to 100A size switches - Cable entries with pre-formed knockouts - Tamper-proof cover with padlockable handle - ...
Primary current: 16 A
VDC: 900 V
... shutdown solution • Solar Cube - solar tracker and measurement controller • Complete range of PV terminals Modular DC Switch IP40 2 Pole 1 String 16A 900VDC Lever
Primary current: 40 A - 1,600 A
VAC: 500, 1,000, 690 V
... the current situation of the switch. And finally they can also check the engine whether the contact blades are noticeable if so, it means that the switch is at 0 point. And if the blades are not noticeable ...
Cefem Group
Primary current: 40 A - 800 A
VAC: 1,000 V
VDC: 1,000 V
... operate the switch. If the contact (blades) are visible then the engine is switched OFF and is in 0 position as seen on the switch. On the contrary if the contacts (blades) are not seen then the switch ...
Cefem Group
Primary current: 40 A - 1,600 A
VAC: 690, 500, 1,000, 400 V
... machines and engines on industrial sites. It can be monitored even by those who are not electricians, without any risk of error of the status of the switch and accordingly the engine, if the contact ...
Cefem Group
Primary current: 400, 630 A
VAC: 12, 24, 36 kV
The Pomanique’s single break, insulator operated disconnector has been designed for both rural distribution and substation type disconnector applications and complying with IEC 60129. Rated voltage from ...
Primary current: 400, 630 A
VAC: 12, 24, 36 kV
The Pomanique’s single break, insulator operated disconnector has been designed for both rural distribution and substation type disconnector applications and complying with IEC 60129. Rated voltage from ...
VAC: 12 kV - 800 kV
Rated frequency:50/60Hz Short time withstand current :up to 63kA Mechanical endurance:M2 Ice breaking capacity:10-20mm Rated insulation level:According to the latest IEC 62271-1 E0,E1* Ambient temperature -60°C to +55°C Altitude ...
Primary current: 32, 63, 100, 125 A
VAC: 230, 400 V
As the main switch in the combination of electrical terminal apparatus, GYH8 isolator is suitable for circuit of AC 50/60Hz, rated voltage 230V/400V, rated current up to 125A for isolating, it also can be used for infrequent ...
Primary current: 630 A - 6,300 A
VAC: 12 kV - 40.5 kV
VDC: 1,500 V - 3,000 V
... contact blades etc. Thoroughly clean the switches and actuator elements prior to putting into operation to remove dust and installation swarf and wipe all insulating parts with a clean dry cloth. The switches ...
Fritz Driescher & Söhne GmbH
Primary current: 20,000, 31,500, 63,000 A
VAC: 24 kV
... dependingon type specified.All switches are type-tested according to EN 62271-102 and are suitable either for vertical mounting (900operating angle) or horizontal mounting (1100 opera-ting angle).For each switch ...
Fritz Driescher & Söhne GmbH
Primary current: 20,000, 31,500, 63,000 A
VAC: 38.5 kV
... dependingon type specified.All switches are type-tested according to EN 62271-102 and are suitable either for vertical mounting (900operating angle) or horizontal mounting (1100 opera-ting angle).For each switch ...
Fritz Driescher & Söhne GmbH
Primary current: 40, 25, 63 A
VDC: 600, 200, 1,000 V
Primary current: 20 A - 125 A
VAC: 400, 230 V
Primary current: 2 A - 63 A
VAC: 400 V
... devices without active electronic components. They are able to switch on, direct and switch off currents under operation-relevant conditions. Fuse switch-disconnector switches ...
Doepke Schaltgeräte GmbH
Primary current: 250, 100, 200 A
VDC: 24 V
Carling Technologies IP67 sealed BD-Series battery disconnect switch is designed to minimize battery drain, ensure maintenance personnel safety, and when used in conjunction with a padlock, provides ...
Carling Technologies
Primary current: 40, 25 A
VAC: 240, 400, 415 V
... 60947-3 Cable Area to Switch Terminal (only Cu) (mm2) / Bolt size - 1.5-16 Color - Yellow / Red Enclosure - M2 Enclosure Type - Polycarbonate IP Rating - 66 Operation - Front-operated Switch ...
KATKO
Primary current: 10, 20 A
VAC: 400, 415, 240 V
... of the material. Cable Area to Switch Terminal (only Cu) (mm2) / Bolt size - 1.5-16 Color - Standard Enclosure - M2 Enclosure Type - ABS IP Rating - 65 Operation - Front-operated Switch type ...
KATKO
Primary current: 16, 25 A
VAC: 240, 400, 415 V
... IEC 60947-3 Cable Area to Switch Terminal (only Cu) (mm2) / Bolt size - 1.5-16 Color - Standard Enclosure - T3 Enclosure Type - Sheet Steel IP Rating - 65 Operation - Front-operated Switch type ...
KATKO
Primary current: 63 A - 1,600 A
Megaswitch is the range of BTicino disconnectors for the industrial applications. These disconnectors, available in five sizes from 63 to 1600 A, are the ideal solution in electrical systems where circuit ...
Primary current: 0 A - 630 A
Gave introduces a new range of NH fuse switch disconnectors characterised by its wide range of size, modularity and scope of accessories. Functions NH fuse switch disconnectors are used on low voltage ...
GAVE ELECTRO
Primary current: 0 A - 125 A
VAC: 440 V
... P-Type Switch is used in many industries and has proven itself to be one of the best switches on the market. Because of it's modular design the switch can meet practically any customer ...
Santon
... industry, coal industry Cast steel solutions for ATEX Zone 1 & 2 use, for flammable liquids, gases & vapour-sand Zone 21 & 22 for dust. EExd II B T6 (certified for gas groups IIA & IIB, temp. class T6) Specifications: - ...
Santon
Primary current: 40 A - 1,600 A
VAC: 415 V
... EN60947/IEC947 the range of‘EFI’ Local Disconnector switches, comprise of highrupturing, quick make and break contacts. The ‘EFI’ range can be used for motor isolating dutiesfor D.O.L and star-delta motors. Switch ...
Santon
Primary current: 200 A
VAC: 25.8 kV
VDC: 24 V
Introduction of item VITZROEM Automatic Section Switch is a switch applied with the first Air-Puffer type arc extinguishing structure and the base insulator type C.T. It is easy to install and operate ...
Primary current: 16 A - 2,000 A
3KD switch disconnectors can be flexibly applied as main control, EMERGENCY-STOP, and maintenance switches. This is possible thanks to versatile connection options, operating mechanism designs, as well as an comprehensive ...
Siemens Low-voltage – Power distribution
Primary current: 600, 900 A
VAC: 25, 38, 15 kV
... to 150 kV EF medium-voltage distribution class disconnects Crossarm mounted with either through bolts or optional clamping arrangement, the type EF disconnect is a robust, securely-mounted switch ...
Siemens Medium-voltage – Power distribution
Primary current: 10 A - 630 A
VAC: 690 V
... the frequency converter Reliable load disconnect switch with positively opening main contacts Functional Description - R. STAHL's 8146/5-V11 series load disconnect switches can be used ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining