Split Core Toroidal Transformer Ø60 for Type A-F Earth Leakage Relays
FRER
Frequency: 47 Hz - 450 Hz
Split Core Toroidal Transformer Ø110 for Type A-F Earth Leakage Relays
FRER
Frequency: 47 Hz - 450 Hz
Split Core Toroidal Transformer Ø160 for Type A-F Earth Leakage Relays
FRER
Primary voltage: 720 V
Primary current: 20 A
Frequency: 50 Hz - 60 Hz
... /333 mV Ø10 mm 3 m cable compact split core CT Current transformers are used to reduce the primary current to a value suited to the product connected downstream. The Zelec SPCM transformer is an ...
ZELEC
Primary voltage: 720 V
Primary current: 100 A
Secondary current: 5 A
SPB030 100/5 Ø24 cable or 36 x 25 bar split core CT Current transformers are used to reduce the primary current to a value suited to the product connected downstream. The Zelec SPB transformer is ...
ZELEC
Primary voltage: 720 V
Primary current: 150 A
Secondary current: 5 A
SPB030 150/5 Ø24 cable or 36 x 25 bar split core CT Current transformers are used to reduce the primary current to a value suited to the product connected downstream. The Zelec SPB transformer is ...
ZELEC
Primary current: 100 A - 5,000 A
Small size and easy mounting. Range output burden: 100A - 5000A. High accuracy and reliability. TECHNICAL SPECIFICATION - Indoor use. - Policarbonate with self-extinguishing V0. - Sealable secondary terminals. - Highest voltage ...
... connected to the following toroidal current transformers. They must be crossed by the cables of the line to be controlled; insert the phases and neutral if present. The earth cable must NOT cross the current transformer. NOTE: ...
... to give a signal, if the AC current exceeds a preselected setpoint. The setpoint is adjusted on a potentiometer on the transformer. 2. Current converters. These units converts the primary AC current to a standard 4-20 ...
Primary current: 1 A - 2,500 A
... Core Current Transformers have a magnetic circuit which is splitted two parts and its max. operating votage is 0.72 kV with non-insulated busbars. However they can be used with fully insulated cables on all voltage level. ...
Primary current: 160 A
Characteristics:Hand hold type, leading wire output, audio plug connector(or customized), transient voltage suppressor built in. Application: used for the current measuring, monitoring and protecting of AC motor, lighting equipment ...
Primary current: 600 A
Split-Core Current Transformers Split-Core Current Transformers (CTs) are designed for applications where it is difficult or uneconomical to open the primary conductor to install a solid-core-type current ...
Primary current: 50 A
Split core current transformer which is used to measure AC current only. KEY FEATURES Compact size Secure locking hinge Same Case with different current rating (50 to 120 A.) RELATED APPLICATION ...
... classification for the protection current transformer intended to operate the particular protection device concerned. In addition the classification of protection current transformers indicates accuracy ...
Primary voltage: 660 V
Primary current: 30 A - 12,000 A
Secondary current: 1, 5 A
MSQ-0.66/A series current transformers are used to test , control, display and recording the operation of electrical equipment, as well as protect the equipment against damage, with frequency of 50 or 60 Hz and rated ...
Primary current: 6,000 A
AKH-0.66/K-Φ series current transformer General Current Transformer (CT) is used to transform the high AC current to small easily manageable values. They are connected with the panel meter or relay ...
ACREL CO., LTD.
Primary current: 5 A
The MSQ Series current transformer is constructed to test, control, display and record the running of electrical equipment. This also protects equipment against deterioration. This transformer is attached ...
The very compact ELEQ TQ30 split-core current transformer is especially designed for connection to digital measurement systems. The TQ30 is supplied with color coded secondary leads. All current transformers ...
ELEQ
Primary current: 5 A
Busbar Type Split Core Current Transformer also called Split Core Current Transformer or Openable Current Transformer. It mainly applies for electric system renovation ...
Primary current: 100 A - 5,000 A
Frequency: 60, 50 Hz
• Primary current: 100A-5000A • Sercondary current: 5A, 1A • Standard approval: IEC44-1, BS7626, VDE0414, VL94 • Maximum voltage: 0.72/3kV • Frequency: 50/60Hz • Rated load: 1VA-30VA • Class: 0.5, 1.0, 3.0 • Short-time thermal ...
Primary current: 50 A - 2,000 A
Secondary current: 0.1, 1, 5 A
Primary current: 5, 100, 200 A
Openable current transformer. TAPRV10/100 Openable current transformer - 100/5A primary current - Also available other items with 200/5A primary current.
Capetti Elettronica
Primary current: 50 A
Current Sensor Features ·UL-Listed ·Output 0.333 Volt AC at rated current ·Operates from 50 Hz to 400 Hz ·Phase displacement < 1.0° at rated current ·Accuracy Class 1.0 ·8 ft. 18 AWG white/black leads ·Rated input of 50 Amp ·Custom ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining