- Electricity - Electronics >
- Switch and Relay >
- Plug-in surge arrester
Plug-in surge arresters
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}

Voltage: 120 V - 600 V
SPD2 3P+0 Series - Class II/Type 2/Type 1 CA Pluggable Multi-Pole Surge protection devices (SPDs) provide equipment protection from transient overvoltage events lasting micro-seconds. By limiting the overvoltage to the equipment during ...

Voltage: 120, 240, 400, 480 V
SPD2 4P+0 Series - Class II/Type 2/Type 1 CA Pluggable Multi-Pole Surge protection devices (SPDs) provide equipment protection from transient overvoltage events lasting micro-seconds. By limiting the overvoltage to the equipment during ...

Voltage: 660 V - 1,500 V
Primary current: 5,000 A - 40,000 A
• EN 50539-11 • UL 1449 4th Ed. • IEC 61643-31 STP T2 40 PV is the series of devices that provide advanced overvoltage protection to photovoltaic systems by utilizing Mersen’s optimized dynamic thermal disconnection system, which does ...
Mersen - Electrical Power

Voltage: 400, 460 V
Primary current: 30,000, 140,000 A
Open circuit voltage: 1,500 V
Tested and certified as a protector Type 1+2 according to the standard EN IEC 61643-11. Suitable for Categories I, II, III, IV according to ITC-BT-23. Single-pole protection. Containing zinc oxide varistors to withstand very ...
Aplicaciones Tecnológicas, S.A.

Voltage: 230, 275 V
Primary current: 25,000, 100,000 A
Open circuit voltage: 1.3 kV
Tested and certified as a protector Type 1+2 according to the standard EN IEC 61643-11. Suitable for Categories I, II, III, IV according to ITC-BT-23. Double connection in order to facilitate wiring (limited to 63 A). Single-pole ...
Aplicaciones Tecnológicas, S.A.

Voltage: 300, 320 V
Primary current: 15,000, 65,000, 40,000 A
Open circuit voltage: 1,400 V
The ATSUB P Series, manufactured by Aplicaciones, is a power supply line surge arrester that is suitable for low voltage, heavy duty riser pole underground and overhead applications. It is equipped with various internal management protection, ...
Aplicaciones Tecnológicas, S.A.

Voltage: 150 V - 440 V
-Type 1 + 2 AC multipolar surge protector -In : 20 kA -Iimp: 12,5 kA -Pluggable module for each phase -Remote signaling (option) -EN 61643-11, IEC 61643-11 compliance The DAC1-13 is an extreme duty Type 1+2 pluggable SPD designed ...

Voltage: 800 V
Primary current: 15,000 A
- Type 2 surge protector - 800 Vdc - In : 15 kA - Imax : 40 kA - Pluggable module - Remote signaling (option) - UTE C61-740-51, EN 50539-11 compliance DS50PV/51 are type 2 surge protectors are designed to protect against lightning ...

Voltage: 250 V - 1,000 V
Primary current: 20,000 A - 40,000 A
Photovoltaic Applications Compact equipment for photovoltaic installations. High discharge capacity via zinc oxide varistors and gas dischargers. With thermal separation device. Visual indication of a fault in the ...

Type 3 surge protection device to EN 61643-11, intended for use in protective contact sockets. • Adapter • Disconnection device and function display • Child lock through increased finger touch protection
OBO Bettermann

Voltage: 1,000 V
Primary current: 5,000 A - 40,000 A
Open circuit voltage: 0 kV - 4 kV
PSC PV is the range of combined devices for discharging lightning currents (Type 1 / Class I), and protecting against induced transient overvoltages (Type 2 / Class II), for Photovoltaic installations, in accordance with EN 50539-11. ...
Cirprotec

Voltage: 1,000 V
Primary current: 5,000 A - 40,000 A
Open circuit voltage: 0 kV - 4 kV
PSC PV is the range of combined devices for discharging lightning currents (Type 1 / Class I), and protecting against induced transient overvoltages (Type 2 / Class II), for Photovoltaic installations, in accordance with EN 50539-11. ...
Cirprotec

Voltage: 1,500 V
Primary current: 5,000 A - 40,000 A
Open circuit voltage: 0 kV - 5 kV
PSC PV is the range of combined devices for discharging lightning currents (Type 1 / Class I), and protecting against induced transient overvoltages (Type 2 / Class II), for Photovoltaic installations, in accordance with EN 50539-11. ...
Cirprotec

Voltage: 150, 275, 320 V
Primary current: 12,500 A
Features Endurable,sustains thousands of strikes Status indication LED status indication Uc 150V / 275V / 320V can be achieved Protection class: Type 1+2 , Class I+II Pole number:1P,2P,3P,4P,1+1NPE,3+1NPE BR-12.5M 4P surge ...
Britec Electric Co., Ltd

Voltage: 150, 275, 320 V
Primary current: 12,500 A
Features: Endurable,sustains thousands of strikes. Status indication. LED status indication. Uc 150V / 275V / 320V can be achieved. Protection class: Type 1+2 , Class I+II. Pole number:1P,2P,3P,4P,1+1NPE,3+1NPE. BR-12.5M 3P ...
Britec Electric Co., Ltd

Voltage: 150, 275, 320 V
Primary current: 12,500 A
Features: Endurable,sustains thousands of strikes. Status indication. LED status indication. Uc 150V / 275V / 320V can be achieved. Protection class: Type 1+2 , Class I+II. Pole number:1P,2P,3P,4P,1+1NPE,3+1NPE. BR-12.5M 2P surge ...
Britec Electric Co., Ltd


type 2 surge arresterFV20C/3-1000PVS
Voltage: 1,000 V
Primary current: 20,000 A
1. Description Fatech Type 2 DC surge arrester are are TUV approved, these DC surge protector 1000V SPDs are tested according to IEC61643-31 and EN50539. 2. Characteristics 1)DC surge protective device used for photovoltaic system. ...
FATECH ELECTRONIC (FOSHAN) CO., LTD

Voltage: 220 V
Primary current: 30,000 A
1.Description Fatech Class I+II lightning and surge arresters, is suitable for TT and TN earthing systems. 3P+N construction lightning and surge arresters based on large power metal oxide varistors and assemble a metal oxide varistor ...
FATECH ELECTRONIC (FOSHAN) CO., LTD

Voltage: 220 V
Primary current: 20,000 A
1. Description FATECH Class II surge arresters have large discharge current value, high operating voltage, suitable for TN-C, TN-S, TT and IT grounding systems. The cartridges are pluggable design, could be changed easily. These surge ...
FATECH ELECTRONIC (FOSHAN) CO., LTD


type 2 surge arresterM TNC,M TNS,M TT,M TN,M TT 2P series
Voltage: 400, 230 V
Primary current: 75,000, 100,000, 25,000, 50,000 A
Prewired spark-gap-based type 1 and type 2 combined lightning current and surge arrester consisting of a base part and plug-in protection modules Maximum system availability due to RADAX Flow follow current limitation No tripping of 20 ...
DEHN + SÖHNE

Voltage: 264, 255 V
Primary current: 25,000, 50,000, 100,000 A
High discharge capacity due to powerful creepage discharge spark gap Maximum system availability due to RADAX Flow follow current limitation Easy replacement of protection modules without tools due to module locking system with module ...
DEHN + SÖHNE

Voltage: 255, 150, 320 V
Primary current: 35,000, 50,000, 25,000 A
High discharge capacity due to powerful creepage discharge spark gap Maximum system availability due to RADAX Flow follow current limitation With module release button for replacing protection modules without tools Operating state ...
DEHN + SÖHNE

EAP385/40 Surge Protection Device was designed and manufactured, complying standard GB 18802.1 /EN 61643-11 , Rated voltage 385V, Maximum discharge current 40KA,High Energy Varistor, high effective for lightning protection. Product ...

Primary current: 10,000 A
Two-Pair (Four-Wire) Protection for Low-Voltage Data Lines. The STC-642 Series offers two-pair (four-wire) surge protection modules featuring three-stage hybrid technology. Gas tubes and silicon avalanche components protect equipment ...

Voltage: 1,100 V - 1,500 V
Primary current: 20,000 A
• Vibration and shock withstand capability • Sensitive and reliable state-of-the-art disconnector • Short circuit current rating of 11 kA The ProTec PV product range provides powerful and pluggable protective devices for photovoltaic ...
Raycap

OUR COMPACT SOLUTION FOR MORE SAFETY As a result of the changes in the power grid, the increased use of measuring devices requires better protection against electrical surges. This can be caused by internal factors (e.g. switching ...

Voltage: 150 V - 420 V
Primary current: 60,000 A
Surge arrester for low-voltage power supply system protection against surges at the boundaries from lightning protection zone LPZ 1- LPZ 2 and higher. Class II (C) arrester in accordance with IEC61643-11:2011, UL1449 3rd. ...
Prosurge Electronics Co.,Ltd

Voltage: 12 V
Primary current: 10,000 A
The CCTv12 is constructed to provide the protection of Closed Circuit TV (CCTV) or security cameras. It is equipped with television display scrren, video recording system and security cameras. It is designed in compliance with the CE ...

Voltage: 12 V - 170 V
Primary current: 100,000 A
Features ● KS C IEC 61643-21-certified product (C2 : 8/20us-5kA, D1 : 10/350us-2.5kA) ● Easy installation and maintenance with plug-in type ● Status-indicating LED lamp (separate power source required) ● Compact design facilitating ...

Voltage: 50 V - 200 V
Primary current: 0 mA - 100 mA
The high-performance AR surge arrester absorbs the potential of an inductive lightning surge caused by a lightning discharge to protect electronic instruments. The plug-in arrester consists of a separable main unit and terminal block. ...

Voltage: 250, 800 V
Primary current: 2,500 A
"Data transmission" is the transfer of characters, numbers, statuses, measurements, etc. between different, decentralised units. "Decentralised units" are controls, computers, measurement sensors, actuators, etc. Appropriate surge protection ...

Voltage: 0 V - 5 V
Primary current: 0 A - 5,000 A
FL485 Surge Protection Devices For Twisted-Pairs System -The transmission performance is superior, the insertion loss is small, and there is no network drop phenomenon caused by ground fault, which can effectively eliminate various ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining