Voltage: 120 V - 600 V
The SPD2 3P+0 series is a surge protection device that safeguards components from transient overvoltage or surges that last micro-seconds by limiting the fault current to a load or the unit being protected. The majority of surges are caused by equipment ...
Littelfuse
type 1 surge arresterDB M MOD series
Voltage: 255, 150, 320 V
Primary current: 35,000, 50,000, 25,000 A
... High discharge capacity due to powerful creepage discharge spark gap Maximum system availability due to RADAX Flow follow current limitation With module release button for replacing protection modules without tools Operating state / fault indication ...
DEHN + SÖHNE
Voltage: 660 V - 1,500 V
Primary current: 5,000 A - 40,000 A
... • EN 50539-11 • UL 1449 4th Ed. • IEC 61643-31 Surge-Trap® Pluggable STPT12 Series - YPV is the PHOTOVOLTAIC range of combined Type 1+2/Class I+II devices intended for discharging lightning currents (10/350 μs) and protecting against induced voltage ...
Mersen - Electrical Power
... Type 3 surge protection device to EN 61643-11, intended for use in protective contact sockets. • Adapter • Disconnection device and function display • Child lock through increased finger touch protection ...
OBO Bettermann
Voltage: 0 V - 150 V
Primary current: 5,000 A - 15,000 A
Open circuit voltage: 10 kV
... Main features
- Type 2 (or 3) AC surge protector (SPD)
- Monitored internal back-up fuse (no external back-up fuse required)
- Internal thermal disconnector with mechanical indicator and optional remote signalling
- Nominal
Voltage: 250 V - 1,000 V
Primary current: 20,000 A - 40,000 A
... • Compact equipment for photovoltaic installations. • High discharge capacity via zinc oxide varistors and gas dischargers. • With thermal separation device. • Visual indication of a fault in the equipment. • Remote signalling of protection status. • ...
Voltage: 0 V - 275 V
Primary current: 7,000, 20,000 A
... Surge Ratings: |, = up to 20 kA (8/20us) lim 7 UP to 12.5 kA (10/350 s) Compliance: IEC 61643-11:2011 | EN61643-11:2012 Network Systems: TN-S, TN-C, TT (only L-N) Mode of Protection: L-PE, N-PE (only TN-S), L-PEN, L-N Location of Use: Main Distribution ...
NORDEL
Voltage: 0 V - 275 V
Primary current: 7,000, 20,000 A
... Surge Ratings: |, = up to 20 kA (8/20us) lim 7 UP to 12.5 kA (10/350 s) Compliance: IEC 61643-11:2011 | EN61643-11:2012 Network Systems: TN-S, TN-C, TT (only L-N) Mode of Protection: L-PE, N-PE (only TN-S), L-PEN, L-N Location of Use: Main Distribution ...
NORDEL
Voltage: 0 V - 275 V
Primary current: 7,000, 20,000 A
... Surge Ratings: lm 7 KA(10/350 us) | 1,5 20 kA (8/20 Hs) Compliance: IEC 61643-11:2011 | EN61643-11:2012 Network Systems: TN-S, TN-C, TT (only L-N) Mode of Protection: L-PE, N-PE (only TN-S), L-PEN, L-N Location of Use: Main Distribution Boards Housing: ...
NORDEL
Voltage: 220 V
Primary current: 25,000, 50,000 A
... Lightning and surge arrester for single phase lines (F + N) 220 V. Combined type 1 and 2 (Class B + C) protector, suitable for protection of low voltage lines against lightning strikes and surges of up to 50kA (10/350) in TT (TNS) networks. Recommended ...
INGESCO
Voltage: 380 V
Primary current: 25,000, 100,000 A
... Lightning and surge arrester for three phase lines (3F+N) 380 V. Combined type 1 and 2 (Class B + C) protector, suitable for protection of low voltage lines against lightning strikes and transitory surges of up to 100kA (10/350) in TT (TNS) networks. ...
INGESCO
Voltage: 230 V
Primary current: 12,500, 25,000 A
... Lightning and surge arrester for single phase lines (F+N) 230 V. Combined type 1 and 2 (Class B + C) protector, suitable for protection of low voltage lines against lightning strikes and surges of up to 25kA (10/350) in TT (TNS) networks. Recommended ...
INGESCO
Voltage: 275, 320, 150 V
Primary current: 12,500, 25,000 A
... Type 1+2, T1+T2, B+C, I+II, Iimp 12.5 kA is developed as the best solution available to protect service entrance at industrial sites. It is designed to meet all your needs for any low voltage installation. It is easy to install in any standardized distribution ...
Britec Electric Co., Ltd
Voltage: 150 V - 440 V
Primary current: 20,000, 40,000 A
... Pole number: 1P, 2P, 3P, 4P, 3P+N, 1P+N. SEMKO approval. The reaction time of less than 25 ns. Thermal stability 100A without additional protection. Color of visible window shows operating status, normal green, red fault. Remote signaling can select. Patented ...
Britec Electric Co., Ltd
Voltage: 1,000, 1,200 V
Primary current: 20,000, 40,000 A
... These units must be installed in parallel on the DC networks to be protected Built-in over current and over heat, temperature control open circuit technology. Adopt independent intelligence property right and high performance sensitivity resistance ...
Britec Electric Co., Ltd
Voltage: 400, 460 V
Primary current: 30,000, 140,000 A
Open circuit voltage: 1,500 V
... Protector for power supply lines. Single-pole. Type 1+2. Uc = 460 VAC. Iimp = 30 kA. Imax =140 kA. Up(1,2/50) = 1500 V. Size 4DIN. Tested and certified as a protector Type 1+2 according to the standard EN IEC 61643-11. Suitable for Categories I, ...
Aplicaciones Tecnológicas, S.A.
Voltage: 320, 300, 600, 1,100, 1,500 V
Primary current: 20,000, 5,000, 15,000 A
... Surge protection device type 2 with plug-in cartridge, rated discharge current In (8/20μs) 20kA per pole, 1P+N •Type of product: SPD •Type of system: 230/400VAC •Type / Class: 2 •Number of poles: 1P+N •In [kA]: 20 •Type of mounting: Din rail ...
LOVATO ELECTRIC
Voltage: 1,100 V - 1,500 V
Primary current: 20,000 A
... • Vibration and shock withstand capability • Sensitive and reliable state-of-the-art disconnector • Short circuit current rating of 11 kA The ProTec PV product range provides powerful and pluggable protective devices for photovoltaic systems up to ...
Raycap
Voltage: 400, 230 V
Primary current: 20,000 A
EGARA 1 LF with Leakage Current Free is a range of devices Type 1+2/Class I+II which are designed to protect electrical installations from lightning strikes (10/350 μs) and induced voltage surges (8/20 μs). Ideal for protection upstream of smart-meters ...
Cirprotec
type 2 surge arresterFV20C/3-1000PVS
Voltage: 1,000, 1,200 V
Primary current: 20,000, 40,000 A
... 1. Description Fatech Type 2 DC surge arrester are are TUV approved, these DC surge protector 1000V SPDs are tested according to IEC61643-31 and EN50539. 2. Characteristics 1)DC surge protective device used for photovoltaic system. 2)The core parts ...
FATECH ELECTRONIC (FOSHAN) CO., LTD
... EAP385/40 Surge Protection Device was designed and manufactured, complying standard GB 18802.1 /EN 61643-11 , Rated voltage 385V, Maximum discharge current 40KA,High Energy Varistor, high effective for lightning protection. Product Benefits Prewired ...
... OUR COMPACT SOLUTION FOR MORE SAFETY As a result of the changes in the power grid, the increased use of measuring devices requires better protection against electrical surges. This can be caused by internal factors (e.g. switching operations) as well ...
Primary current: 10,000 A
... Two-Pair (Four-Wire) Protection for Low-Voltage Data Lines. The STC-642 Series offers two-pair (four-wire) surge protection modules featuring three-stage hybrid technology. Gas tubes and silicon avalanche components protect equipment from overvoltage ...
Voltage: 12 V
Primary current: 10,000 A
... The CCTv12 is constructed to provide the protection of Closed Circuit TV (CCTV) or security cameras. It is equipped with television display scrren, video recording system and security cameras. It is designed in compliance with the CE standards. Moreover, ...
Voltage: 30 V - 500 V
Primary current: 0 mA - 100 mA
... The high-performance AR surge arrester absorbs the potential of an inductive lightning surge caused by a lightning discharge to protect electronic instruments. The plug-in arrester consists of a separable main unit and terminal block. Absorbs large ...
Voltage: 250, 800 V
Primary current: 2,500 A
VARITECTOR SPC besticht durch einen steckbaren Ableiter, der einen einfachen Austausch bzw. Prüfbarkeit ermöglicht ohne die Verdrahtung zu lösen. Wartungsintervalle werden so spielend einfach mit dem V-TEST Prüfgerät ermöglicht. Weiterhin bietet der einfach ...
Voltage: 0 V - 5 V
Primary current: 0 A - 5,000 A
... FL485 Surge Protection Devices For Twisted-Pairs System -The transmission performance is superior, the insertion loss is small, and there is no network drop phenomenon caused by ground fault, which can effectively eliminate various interferences ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group