Temperature: -55 °C - 155 °C
... Excellent high temperature Low temperature Ozone & weathering resistance Flame retardant Soldering iron resistant Easy to strip & process Compatible to all common resins and varnishes Flexible How to use it ...
Nominal voltage: 6 kV
Temperature: -55 °C - 80 °C
... 320 ‒ 480 MHz As Specified by Customer 820 ‒ 960 MHzAs Specified by Customer 1700 ‒ 1880 MHzAs Specified by Customer 1880 ‒ 2180 MHzAs Specified by Customer 2300 ‒ 2500 MHzAs Specified by Customer 2500 ‒ 2700 MHzAs Specified by Customer Attenuation ...
Yangtze Optical Fibre and Cable Joint Stock Limited Company
Nominal voltage: 80 kV - 320 kV
... are far from shore (>70km). HVDC submarine cables are typically single-core cables with extruded insulation and metallic radial water barrier. ZTT has the capability of manufacturing the HVDC submarine ...
Nominal voltage: 80, 300 V
Temperature: -20 °C - 60 °C
... 1010A Category 3 U/UTP Cable, non-plenum, slate jacket, 4 pair count, 1000 ft (305 m) length, WE TOTE® box ...
COMMSCOPE
Nominal voltage: 450, 500, 750, 300 V
Temperature: -55 °C - 145 °C
Cross-section: 0.25 mm² - 240 mm²
... IEC 60811-404, IRM 902 4h at +70°C certifications and approvals: EAC 0.5 - 240 mm²: DNV GL Temperature resistant single core for the internal wiring of lighting fixtures, heaters, electrical machinery, switching ...
HELUKABEL
Length: 8 m
The arc detecting fiber sensor PGA-LS25 (5 m (16.4 ft) active; 8 m (26.2 ft) total) is built to detect arcs along its entire length. It is meant to be installed with the fiber along the back wall of switchboards, covering all compartments with just one ...
Temperature: -65 °C - 260 °C
Cross-section: 0.5 mm²
... Standard cables with the highest quality Our automotive cables are the reliable and efficient connection for each wiring system. We offer an extensive range of products with various OEM and Tier 1 approvals. We supply ...
LEONI Cable Solutions
Nominal voltage: 1 kV - 500 kV
Temperature: 0 °C - 90 °C
... Transmission Medium voltage power cable composite with O.F. The Min.bending radius: Single-core:20D, mm multi-core cable: 15D, mm(D means actual cable diameter). Low voltage ...
Nominal voltage: 600, 1 V
Temperature: -40 °C - 90 °C
Cross-section: 0.75 mm² - 240 mm²
... Marking for SABIX® BL 402 FRNC 64020182: SAB BRÖCKSKES · D-VIERSEN · SABIX® BL 402 FRNC 1,5mm² - IEC 60332-3-22 - 0,6/1kV DNV CE and current meter marking Especially for use in shipbuilding industry! asbestos-free no flame propagation for applications ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 1, 600 kV
Temperature: -40 °C - 90 °C
Cross-section: 0.75 mm² - 240 mm²
... 2009) of the IMO approvals: DNV Possible on request: bare copper strands alternative colour code and sheath colour Conductor - tinned copper strands acc. to IEC 60228, VDE 0295, class 5 Insulation - special SABIX® Colour ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 4,000, 1, 600 V
Temperature: -40 °C - 90 °C
Cross-section: 0.75 mm² - 240 mm²
... halogen-free flexible power cable with overall copper screen 0,6/1 kV Marking for SABIX® BL 409 C FRNC 64090186: SAB BRÖCKSKES · D-VIERSEN · SABIX® BL 409 C FRNC 4,0mm² - IEC 60332-3-22 - 0,6/1kV DNV CE and current meter marking Especially ...
SAB BROECKSKES GMBH & Co. KG
... Galvanized steel round conductor Principally indicated for capture mesh conductors and down conductor connections in lightning protection systems. Characteristics • Economical. • 125m ...
Temperature: -40 °C - 105 °C
Cross-section: 8 mm²
... DescriptionPower cable with 8AWG (8 mm²) cross-section for battery or DC motor power supply. Ultra-flexible PVC sheath and high-temperature insulation (rated to 200°C). Rated current: 80 A. Sold by the metre for custom lengths.DetailsThe ...
OZO
Temperature: 200 °C
Cross-section: 20 mm²
... DescriptionRed multi-strand power cable 4AWG (20 mm²) with high-temperature silicone jacket for motor or battery cables in electric motorcycles, electric cars, karting, quads, car audio, solar systems and boats.CompositionConductor: ...
OZO
Nominal voltage: 600 V
Temperature: -40 °C - 200 °C
Cross-section: 95 mm²
... flexibility.ApplicationsUsed as motor cable to power brushless DC motors (up to 600V).Battery cable for electric cars, electric motorcycles, sailboats, boats, karting.Solar installations, car-audio and other systems requiring ...
OZO
Nominal voltage: 300, 500, 450, 750 V
Temperature: -50 °C - 90 °C
Cross-section: 120 mm² - 500 mm²
... applications and to connect electrical devices we offer our TPE-U insulated cables for a voltage range 300/500 V or 450/750 V. The electrical conductor consists out of a round stranded copper cable with ...
... • - 4.5m cable and connector that connects a mat to ground • - Resistor 1 Meg mat to ground • - Meets the requirements of ANSI/ESD S-20.20 and EIA625 • - Available Colours: Not Defined Description Part of our specialized line ...
... ensure static electricity will flow to ground in a controlled manner. ESD Coil Cord is a 1.8 m cable which connects wristbands to common grounding point on a table mat. With a 1 Meg resistor, the 10 mm socket snaps ...
Length: 4.5 m
... Assures that all parts are the same ground potential Resistor 1 Meg mat to ground Available with a ring terminal or 10mm female socket Product description Specialized line of ESD accessories to ensure a static free workplace and ...
Nominal voltage: 300, 400 V
Temperature: -70 °C - 260 °C
... Elongation Retention calculates the activation energy of the insulation coating material. Application Single-core wires or multi-core cables are used in nuclear power plants. 1. Advantages The elongation ...
Nominal voltage: 600 V
Temperature: -200 °C - 300 °C
... maglev field. Medical equipment MRI signal cables, detection of superconducting magnets and their feeder systems, superconducting solenoid signal cables, ultra-low temperature and high field insulated cables. Advantages ...
Nominal voltage: 300 V
Temperature: -50 °C - 180 °C
Cross-section: 0.14 mm²
... Control Cable, twisted core 1 or 3 conductors. Spiral wrap covering the core with overlapping halogen free special heat resistant foil. number of cores: - 1, 3 ...
Metrofunk Kabel-Union
Nominal voltage: 300 V
Temperature: -50 °C - 180 °C
Cross-section: 0.5 mm²
... Control Cable, twisted core 1 or 3 conductors. Spiral wrap covering the core with overlapping halogen free special heat resistant foil. number of cores: 1, 3 ...
Metrofunk Kabel-Union
Nominal voltage: 600 V
Temperature: -100 °C - 200 °C
Cross-section: 0.06 mm²
... Cable, 0,06mm², Teflon-FEP insulated, shielded, Teflon-FEP jacket, white: temperature resistant, heat resistant, flexible number of cores: 1, 2, 3, 4 ...
Metrofunk Kabel-Union
Nominal voltage: 300 V - 1,000 V
Temperature: -40 °C - 90 °C
Cross-section: 1.5 mm² - 240 mm²
IC AUTOMATION
Nominal voltage: 600, 1,000 V
Temperature: -40 °C - 80 °C
Cross-section: 0.38 mm² - 95 mm²
IC AUTOMATION
Nominal voltage: 300, 500 V
Temperature: -180 °C - 1,200 °C
Cross-section: 0.5 mm² - 185 mm²
IC AUTOMATION
... permanent installation are designed with solid copper conductors. For flexible applications, BizLink offers an extremely flexible Industrial trailing patch cable with fine-strand conductors. Next ...
Temperature: -40 °C - 70 °C
... CATV-/Antenna cables to transmit high quality data to TV and new multimedia applications. New applications in CATV networks such as broadband internet and services are a challenge for network providers because they require high-quality ...
Prysmian Group
Temperature: -30 °C - 60 °C
... optimized design of high-speed cable pitch technology production process greatly improves crosstalk And the transmission performance index margin such as return loss, etc., to obtain a higher transmission bandwidth. Adopt unique cable ...
Zhaolong Interconnect
Nominal voltage: 1 kV
... =3.6kV) VV22/VLV22-0.6/1-kV- single-core - VV22/VLV22-0.6/1-kV-multi core 1. Conductor: Copper or aluminum, Class 1: solid conductor, or Class 2: stranded conductor 2. ...
Henan Tong-Da Cable Company
... .7A, PVC, CM Rated, 23AWG Shielded Round Solid Cable For 10G+ Ethernet To elevate your network with high-quality PRIME Cat.7A Bulk Ethernet Lan Cable. With dual shielding with braid and foil and 100% ...
CRXCONEC
Nominal voltage: 76 kV - 500 kV
Temperature: 90 °C
Cross-section: 240 mm² - 2,500 mm²
... you: from consulting on design through to implementation of your sophisticated high-voltage cable systems. Brugg Cables advises customers world-wide on new cable systems, as well as expanding or converting ...
Brugg Kabel AG
Temperature: -40 °C - 180 °C
Cross-section: 1 mm² - 95 mm²
Nominal voltage: 250 V
Temperature: -30 °C - 80 °C
... For wiring of industrial field bus systems like PROFIBUS DP, F.I.P. With solid conductor AWG22/1 for hard wiring or with 7-wire stranded conductor for moving use without compulsory guide in the automation ...
... drop cable Range up to 50m depending on climatic conditions (consult us) Compactness : outer diameter 5mm, inner diameter 2.3mm Easy extraction of the subscriber line without cut-off point to ensure a better optical ...
Acome
Temperature: -40 °C - 260 °C
Cross-section: 0.22 mm² - 120 mm²
... With LEONI Mocar we offer single-core cables which are especially used in powertrain and engine systems. Even for sensors with high ambient temperatures they are the reliable connection. The cables are ...
LEONI
Nominal voltage: 750, 300, 500, 450 V
Temperature: 70 °C
Cross-section: 1.5 mm² - 400 mm²
... temperature for cable installtion:≥ 0℃ 3.3、: Permissible bending radius of cables: Cable outer-diameter under 25 mm, not less than four times of cable OD。 ②.25mm: 。 Cable ...
Shanghai Morn Electric Equipment Company
Nominal voltage: 600 V - 1,000 V
Temperature: 1,000 °C - 1,400 °C
... Single conductor cable for very high temperatures, composite insulation, THS 1500 Applications : Heavy industry Heating appliances Heating elements Nuclear industry Shipbuilding, railways Operating ...
OMERIN
Temperature: -25 °C - 75 °C
Length: 1,000 m
... Telephone cables for interiors with LS0H sheath. SYT1-SH Indoor cables from 3 to 112 pairs, copper conductors with diameters of 0.5, 0.60 and 0.90 mm . Solid PE insulation twisted ...
CABLESCOM
... YJLHV Unarmored Cable Applicable Erection Occasion Indoor, tunnel, cable ditch and other occasions. The cable cannot withstand external mechanical force, and single-core cable ...
Nominal voltage: 33 kV
Temperature: 20, 30 °C
... insulation. 3.Max conductor temperature during cable short circuit: 250℃ for XLPE insulation (max. duration is 5 sec.) 4.Min. bending radius of cable during installation: (1) Single-core ...
Nominal voltage: 300 V
Temperature: 80 °C
... • Solid or strands, tinned or bare copper conductor 32-16AWG; • PVC insulation .comply with ROHS environmental standard • Uniform insulation thickness to ensure easy stripping and cutting; • Pass UL VW-1 ,CSA FT 1 ...
Yueqing RunEasy Electronic Technology Co.,Ltd.
Nominal voltage: 600 V - 1,000 V
Temperature: -40 °C - 90 °C
Cross-section: 25 mm² - 400 mm²
... TOXFREE® RZ1 AL is an aluminium LSZH cable for fixed installations. These cables are especially recommended for installation in public places and in instalations where safety is a priority. 1. Conductor Aliuminium, ...
Top Cable
Nominal voltage: 600 V - 1,000 V
Temperature: 0 °C - 90 °C
Cross-section: 1.5 mm² - 35 mm²
... seconds.
Guangzhou Yuhong Technology CO., Ltd
Nominal voltage: 300 V
Temperature: -20 °C - 80 °C
... LCAE MPU222-100 cable, insulated with PE, low capacitance, is used for LonWorks level IV applications. Product range - Axindus Type of assembly - Pairs Shielding Y/N - No Green/Yellow Conductor - No OBSO_Static ...
CAE GROUPE
... Taisuo has a large quantity of MI cable in stock in various types, diameters and sheath materials, which ensures the quickest delivery time. Nice endings and high accuracy conforms to IEC584 Grounded and ungrounded, minumum outer sheath ...
... Industrial wires & cable can be used at various locations, and support worksites with useful products meet the needs. Medium/Low Voltage Electric Wires/ Cables Used for essential social infrastructure. We propose optimal ...
... RF195 low loss coaxial cable is a 5mm diameter low loss cable suitable for cable runs up to 10M for cellular, GNSS, UHF and WiFi frequency bands RF195 low loss RF cable is suitable ...
Length: 10 mm
... Super low loss double shielded solid core 10mm cable Use for long cable runs in fixed installations. Panorama offers a range of Ultra low loss C400 extension cables fitted with N ...
Temperature: -20 °C - 70 °C
Length: 100 m