- Electricity - Electronics >
- Cable, Connector, Enclosure >
- Single-conductor electrical cable
Single-conductor electrical cables
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}

Nominal voltage: 300 V
Temperature: 80 °C
• Solid or strands, tinned or bare copper conductor 32-16AWG; • PVC insulation .comply with ROHS environmental standard • Uniform insulation thickness to ensure easy stripping and cutting; • Pass ...
Yueqing RunEasy Electronic Technology Co.,Ltd.

Temperature: -55 °C - 155 °C
... & process • Compatible to all common resins and varnishes • Flexible • For protected and fixed installation inside electrical equipment, especially suitable for the connection of motor windings, switchboards, magnets ...

Nominal voltage: 6 kV
Temperature: -50 °C - 250 °C
Cross-section: 1 mm² - 300 mm²
Highly flexible Besilen® insulated HV single core, shielded This hv cable is for example appropriate for the connection of converters to E-mobility test benches. Due to the high voltage rating the ...
SAB BROECKSKES GMBH & Co. KG

Nominal voltage: 600, 1 V
Temperature: -40 °C - 90 °C
Cross-section: 0.75 mm² - 240 mm²
Marking for SABIX® BL 402 FRNC 64020182: SAB BRÖCKSKES · D-VIERSEN · SABIX® BL 402 FRNC 1,5mm² - IEC 60332-3-22 - 0,6/1kV DNV CE and current meter marking Especially for use in shipbuilding industry! asbestos-free no flame propagation for ...
SAB BROECKSKES GMBH & Co. KG

Nominal voltage: 1, 600 kV
Temperature: -40 °C - 90 °C
Cross-section: 0.75 mm² - 240 mm²
... 2009) of the IMO approvals: DNV Possible on request: bare copper strands alternative colour code and sheath colour Conductor - tinned copper strands acc. to IEC 60228, VDE 0295, class 5 Insulation - special ...
SAB BROECKSKES GMBH & Co. KG

Cross-section: 4 mm²
The single-pole, silicone-free steel core spiral cables from REMBE® offer superior mechanical strength. The steel core used can withstand continuous daily use and its cable sheath is ...

• - 4.5m cable and connector that connects a mat to ground • - Resistor 1 Meg mat to ground • - Meets the requirements of ANSI/ESD S-20.20 and EIA625 • - Available Colours: Not Defined Description Part ...

• - 1.8m cable • - 1 Meg resistor • - 10 mm socket snaps to wristband, and the other end is a banana plug • - Meets the requirements of EOS/ESD S1, M-STD-1686, and EIA 625 • - Available Colours: Not Defined Description Part ...

Length: 4.5 m
... Meg mat to ground Available with a ring terminal or 10mm female socket Product description Specialized line of ESD accessories to ensure a static free workplace and protect employees and sensitive electrical ...

Nominal voltage: 300 V
Temperature: -50 °C - 180 °C
Cross-section: 0.14 mm²
Control Cable, twisted core 1 or 3 conductors. Spiral wrap covering the core with overlapping halogen free special heat resistant foil. number of cores: - 1, 3
Metrofunk Kabel-Union

Nominal voltage: 300 V
Temperature: -50 °C - 180 °C
Cross-section: 0.5 mm²
Control Cable, twisted core 1 or 3 conductors. Spiral wrap covering the core with overlapping halogen free special heat resistant foil. number of cores: 1, 3
Metrofunk Kabel-Union

Nominal voltage: 600 V
Temperature: -100 °C - 200 °C
Cross-section: 0.06 mm²
Cable, 0,06mm², Teflon-FEP insulated, shielded, Teflon-FEP jacket, white: temperature resistant, heat resistant, flexible number of cores: 1, 2, 3, 4
Metrofunk Kabel-Union

Nominal voltage: 600 V
Temperature: -20 °C - 105 °C
• Unipolar flexible cable with UL 758, UL 1581, C22.2 No. 210.2-M90 marks • UL file No. E132504, CSA file No. LL 90483. • Flexible or rigid electrolytic tinned copper conductor • Special PVC insulation ...
PONY SRL

Nominal voltage: 600 V
Temperature: -20 °C - 105 °C
... and CSA marked flexible unipolar insulated cable, for internal wiring or use in electronic devices not subject to mechanical stress and in fixed installation. • Flexible tinned electrolytic copper conductor • ...
PONY SRL

Nominal voltage: 50 V
Temperature: -40 °C - 105 °C
... Unipolar flexible cable suitable for use on electrical systems, systems and low voltage components of motor vehicles, where exposure to heat sources is not fixed on the surface of the cable. • ...
PONY SRL

Temperature: -20 °C - 70 °C
Length: 100 m
... material : PVC PHYSICAL DATA : • Copper Content : kg/km : 19,1 • Cable Weight : kg/km : 44,1 • Min bending radius x 1/n : mm : 35/70 • Max.Tensile Strength : N : 150 ELECTRICAL DATA : • ...
Cavel

Temperature: -40 °C - 80 °C
Length: 100, 500 m
... material : PVC PHYSICAL DATA : • Copper Content : kg/km : 12,6 • Cable Weight : kg/km : 43,9 • Min bending radius x 1/n : mm : 35/70 • Max.Tensile Strength : N : 120 ELECTRICAL DATA : • ...
Cavel

Temperature: -40 °C - 80 °C
Length: 500 m
... material : PE PHYSICAL DATA : • Copper Content : kg/km : 83,1 • Cable Weight : kg/km : 188,4 • Min bending radius x 1/n : mm : 200 • Max.Tensile Strength : N : 800 ELECTRICAL DATA : • Impedance ...
Cavel

Nominal voltage: 300, 500, 450, 750 V
Temperature: -50 °C - 90 °C
Cross-section: 120 mm² - 500 mm²
... current cables 300/500 V resp. 450/750 V Construction and application For high current applications and to connect electrical devices we offer our TPE-U insulated cables for a voltage ...

Temperature: -55 °C - 200 °C
Length: 0.5 m
... insulated coaxial cables and connectors toensure an insulation resistance greater than 1013 Ω throughoutthe measuring chain. Only low noise coaxial cables that produce very little triboelectricity ...
Kistler

Temperature: -55 °C - 200 °C
Length: 0.5 m
Green, single-wire, high insulation, PFA based cable (ø2 mm) for sensors with KIAG 10-32 neg. connector. Charge mode, high impedance piezoelectric measurement demands highly insulated coaxial cables ...
Kistler

Temperature: -40 °C - 200 °C
Length: 1 m
... connecting cables are low-noise and high-insulation coaxial cables for use in drag-chains. Owing to their own properties, the blue cables are especially well suited for dynamic use. Thanks ...
Kistler

Galvanized steel round conductor Principally indicated for capture mesh conductors and down conductor connections in lightning protection systems. Characteristics • Economical. ...

Nominal voltage: 300 V - 1,000 V
Temperature: -40 °C - 90 °C
Cross-section: 1.5 mm² - 240 mm²
IC AUTOMATION

Nominal voltage: 600, 1,000 V
Temperature: -40 °C - 80 °C
Cross-section: 0.38 mm² - 95 mm²
IC AUTOMATION

Nominal voltage: 300, 500 V
Temperature: -180 °C - 1,200 °C
Cross-section: 0.5 mm² - 185 mm²
IC AUTOMATION

Temperature: -40 °C - 70 °C
Length: 25 cm
... modular 1-Wire interface cables are available for the NX-200, LX2/MX2 series, the NX-900 series and the CX1 warp. The modular 1-Wire interface are delivered with a RJ-45 connector for easy connection ...

Canare 75 ohm Super Low Loss Coaxial Cable ・Best suited to 3G-SDI/HD-SDI transmission. ・Highly-foamed PE insulation allows further improvement in the attenuation characteristics. ・Multi-layer insulation in which to ...

Nominal voltage: 300 V
Temperature: -20 °C - 80 °C
LCAE MPU222-100 cable, insulated with PE, low capacitance, is used for LonWorks level IV applications. Product range - Axindus Type of assembly - Pairs Shielding Y/N - No Green/Yellow Conductor ...
CAE GROUPE

Nominal voltage: 300 V
Temperature: -20 °C - 80 °C
LCAE MPS 122-100 cable, insulated with PE, low capacitance is used for LonWorks level IV applications. Product range - Axindus Type of assembly - Pairs Shielding Y/N - Yes Green/Yellow Conductor ...
CAE GROUPE

Nominal voltage: 450, 750 V
Temperature: -5 °C - 70 °C
Cross-section: 1.5 mm² - 120 mm²
H07V-K harmonised flexible wiring cables are used for equipping electrical cabinets and internal equipment wiring. They are available in the usual standard colours. Product range - Axindus Type of ...
CAE GROUPE

Nominal voltage: 6 kV
Temperature: -55 °C - 80 °C
320 ‒ 480 MHz As Specified by Customer 820 ‒ 960 MHzAs Specified by Customer 1700 ‒ 1880 MHzAs Specified by Customer 1880 ‒ 2180 MHzAs Specified by Customer 2300 ‒ 2500 MHzAs Specified by Customer 2500 ‒ 2700 MHzAs Specified by ...
Yangtze Optical Fibre and Cable Joint Stock Limited Company

Temperature: -65 °C - 260 °C
Cross-section: 0.5 mm²
Standard cables with the highest quality Our automotive cables are the reliable and efficient connection for each wiring system. We offer an extensive range of products with various OEM and Tier 1 ...
LEONI AG

Nominal voltage: 450, 500, 750, 300 V
Temperature: -55 °C - 145 °C
Cross-section: 0.25 mm² - 240 mm²
... C certifications and approvals: EAC 0.5 - 240 mm²: DNV GL Temperature resistant single core for the internal wiring of lighting fixtures, heaters, electrical machinery, switching ...
HELUKABEL

... ® motor cables are available as PVC and TPE motor cables and as multi-core and single-core cables. Flame-retardant, oil-resistant, halogen-free and UV-resistant versions ...

Temperature: -30 °C - 60 °C
... optimized design of high-speed cable pitch technology production process greatly improves crosstalk And the transmission performance index margin such as return loss, etc., to obtain a higher transmission bandwidth. Adopt ...
Zhaolong Interconnect

Nominal voltage: 1 kV
... =3.6kV) VV22/VLV22-0.6/1-kV-single-core - VV22/VLV22-0.6/1-kV-multi core 1. Conductor: Copper or aluminum, Class 1: solid conductor, or Class 2: stranded conductor 2. ...
Henan Tong-Da Cable Company

Nominal voltage: 80 kV - 320 kV
... are far from shore (>70km). HVDC submarine cables are typically single-core cables with extruded insulation and metallic radial water barrier. ZTT has the capability of manufacturing ...

... permanent installation are designed with solid copper conductors. For flexible applications, BizLink offers an extremely flexible Industrial trailing patch cable with fine-strand conductors.

Nominal voltage: 500, 300 V
Temperature: -50 °C - 700 °C
Cross-section: 0.5 mm² - 50 mm²
• Suitable for areas where the installation temperature and ambient temperature is very high • Good electrical conductivity due to nickel strand also at high temperatures • Heating modules, electric heating devices, ...
Lapp France

Temperature: -40 °C - 260 °C
Cross-section: 0.22 mm² - 120 mm²
With LEONI Mocar we offer single-core cables which are especially used in powertrain and engine systems. Even for sensors with high ambient temperatures they are the reliable connection. The cables ...
LEONI
Your suggestions for improvement:
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining