Nominal voltage: 300 V
Temperature: 80 °C
• Solid or strands, tinned or bare copper conductor 32-16AWG; • PVC insulation .comply with ROHS environmental standard • Uniform insulation thickness to ensure easy stripping and cutting; • Pass ...
Yueqing RunEasy Electronic Technology Co.,Ltd.
Nominal voltage: 6 kV
Temperature: -55 °C - 80 °C
320 ‒ 480 MHz As Specified by Customer 820 ‒ 960 MHzAs Specified by Customer 1700 ‒ 1880 MHzAs Specified by Customer 1880 ‒ 2180 MHzAs Specified by Customer 2300 ‒ 2500 MHzAs Specified by Customer 2500 ‒ 2700 MHzAs Specified by ...
Nominal voltage: 10,000, 8,000 V
Temperature: -40 °C - 80 °C
Cable Type: RFXT 7/8 1.Smooth Copper Tube 2.Foamed PE Dielectric 3.Longitudinally Wrapped Copper Strip 4.PE Jacket or LSZH
Nominal voltage: 150 V
Temperature: -30 °C - 120 °C
... layout and cable assembly Coaxial cable Triaxial cable Video cable Audio cable Multiconductor cable PTFE cable PUR ...
... layout and cable assembly Coaxial cable Triaxial cable Video cable Audio cable Multiconductor cable PTFE cable PUR ...
Nominal voltage: 60, 600 V
Temperature: -55 °C - 150 °C
Cross-section: 0.35 mm² - 10 mm²
... surface and the diameter of the capillary tube. Copper conductors in general are leaking due to cavity between single copper wires and cavity between conductor and insulation. RADOX® ...
... Chainflex® motor cables for Energy Chains® designed for heavy duty use, tested numerously and available in PVC, TPE motor cables also in single and multi-core motor cable ...
igus®
... permanent installation are designed with solid copper conductors. For flexible applications, BizLink offers an extremely flexible Industrial trailing patch cable with fine-strand conductors.
Nominal voltage: 300, 500 V
Temperature: -40 °C - 70 °C
Cross-section: 1.5 mm² - 35 mm²
... 332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2 certifications and approvals: EAC re = round, solid conductor rm = round, stranded conductor the conductor is metrically ...
HELUKABEL
Nominal voltage: 600, 1 V
Temperature: -40 °C - 90 °C
Cross-section: 0.75 mm² - 240 mm²
Marking for SABIX® BL 402 FRNC 64020182: SAB BRÖCKSKES · D-VIERSEN · SABIX® BL 402 FRNC 1,5mm² - IEC 60332-3-22 - 0,6/1kV DNV CE and current meter marking Especially for use in shipbuilding industry! asbestos-free no flame propagation for ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 1, 600 kV
Temperature: -40 °C - 90 °C
Cross-section: 0.75 mm² - 240 mm²
... 2009) of the IMO approvals: DNV Possible on request: bare copper strands alternative colour code and sheath colour Conductor - tinned copper strands acc. to IEC 60228, VDE 0295, class 5 Insulation - special ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 4,000, 1, 600 V
Temperature: -40 °C - 90 °C
Cross-section: 0.75 mm² - 240 mm²
halogen-free flexible power cable with overall copper screen 0,6/1 kV Marking for SABIX® BL 409 C FRNC 64090186: SAB BRÖCKSKES · D-VIERSEN · SABIX® BL 409 C FRNC 4,0mm² - IEC 60332-3-22 - 0,6/1kV DNV CE and current ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 250 V
Temperature: -30 °C - 80 °C
For wiring of industrial field bus systems like PROFIBUS DP, F.I.P. With solid conductor AWG22/1 for hard wiring or with 7-wire stranded conductor for moving use without compulsory guide ...
• - 4.5m cable and connector that connects a mat to ground • - Resistor 1 Meg mat to ground • - Meets the requirements of ANSI/ESD S-20.20 and EIA625 • - Available Colours: Not Defined Description Part ...
• - 1.8m cable • - 1 Meg resistor • - 10 mm socket snaps to wristband, and the other end is a banana plug • - Meets the requirements of EOS/ESD S1, M-STD-1686, and EIA 625 • - Available Colours: Not Defined Description Part ...
... controlled manner. 4.5m cable that connects wristbands and a mat to ground. Easy to install, simply snap it to a mat, plug in the wrist strap coil cord and connect terminal to ground Resistor 1 Meg mat to ground. Available ...
Nominal voltage: 300 V
Temperature: -50 °C - 180 °C
Cross-section: 0.5, 0.25, 0.14 mm²
Control Cable, twisted core 1 or 3 conductors. Spiral wrap covering the core with overlapping halogen free special heat resistant foil.
Metrofunk Kabel-Union
Nominal voltage: 250 V
Temperature: -20 °C - 80 °C
Cross-section: 0.14 mm²
PE-Connection Cable, shielded NF8 (1 x 0,14) shielded PE-connection cable (flash light wire)
Metrofunk Kabel-Union
Nominal voltage: 350 V
Temperature: -20 °C - 80 °C
Cross-section: 0.08 mm²
shielded PE-insulated cable, especially for microphones, sound heads, dictaphones
Metrofunk Kabel-Union
Temperature: -25 °C - 70 °C
Cross-section: 16 mm²
... Diameter 7,5 mm • M4 ring cable lug at both ends
Temperature: 0 °C - 50 °C
Length: 10 m - 250 m
Schielded installation cable for generic cabeling acc. to ISO/IEC 11801 and EN 50173 (2nd edition). Ideal for all applications up to class F multimedia (video, data, voice) > 10 GbE acc. to IEEE 802.3an, cable ...
Nominal voltage: 300 V - 1,000 V
Temperature: -40 °C - 90 °C
Cross-section: 1.5 mm² - 240 mm²
IC AUTOMATION
Nominal voltage: 600 V
Temperature: 80 °C
Cross-section: 0.14 mm² - 95 mm²
IC AUTOMATION
IC AUTOMATION
Temperature: -55 °C - 200 °C
Length: 0.5 m
... insulated coaxial cables and connectors toensure an insulation resistance greater than 1013 Ω throughoutthe measuring chain. Only low noise coaxial cables that produce very little triboelectricity ...
Kistler
Temperature: -55 °C - 200 °C
Length: 0.5 m
Green, single-wire, high insulation, PFA based cable (ø2 mm) for sensors with KIAG 10-32 neg. connector. Charge mode, high impedance piezoelectric measurement demands highly insulated coaxial cables ...
Kistler
Temperature: -40 °C - 200 °C
Length: 1 m
... connecting cables are low-noise and high-insulation coaxial cables for use in drag-chains. Owing to their own properties, the blue cables are especially well suited for dynamic use. Thanks ...
Kistler
Nominal voltage: 300 V
Temperature: -20 °C - 80 °C
For LonWorks BUS application • conform to RoHS conductor material solid bare copper strand conductor class AWG22/1, Ø 0.64 mm core insulation PE core identification Pair 1 White ...
CAE GROUPE
Nominal voltage: 300 V
Temperature: -20 °C - 80 °C
... application. • conform to RoHS conductor material solid bare copper strand conductor class AWG22/1, Ø 0.64mm core insulation PE core identification Pair 1 White - blue stranding ...
CAE GROUPE
Nominal voltage: 450, 750 V
Temperature: -5 °C - 70 °C
Cross-section: 1.5 mm² - 120 mm²
the H05V-K / H07V-K harmonized cabling wires are used for the equipment in electrical boxes and internal wiring of devices. • conform to RoHS conductor material Stranded bare copper conductor ...
CAE GROUPE
... current cables 300/500 V resp. 450/750 V Construction and application For high current applications and to connect electrical devices we offer our TPE-U insulated cables for a voltage ...
... -25% emission for the new UNB1627 range ACOME's UNB connection cable ranges have been designed to meet the connection needs of FTTH access networks. UNB1625 and UNB1627 series cables ensure the wiring ...
Acome
Temperature: 60 °C
Length: 500 m - 1,000 m
... Main remote control and remote transmission cable, installed in multi-tubular sheaths, under roads or pavements, along DC-electrified lines up For "rail" or "tyre" tram lines at dedicated sites Red copper solid ...
Acome
Temperature: 60 °C
Length: 500 m
... International benchmark for tunnel cables Exceptional fire performance and mechanical properties Main cable for signal, remote control and remote transmission, installed in ducts, cable ...
Acome
Nominal voltage: 600 V - 1,000 V
Temperature: 1,000 °C - 1,400 °C
Single conductor cable for very high temperatures, composite insulation, THS 1500 Applications : Heavy industry Heating appliances Heating elements Nuclear industry Shipbuilding, ...
OMERIN
Temperature: 105 °C - 1,200 °C
Wires with conductors for all types of thermocouple (also, extension and compensation) and silver copper conductors for RTDs. Conductors can be solid or stranded, ...
Temperature: 70 °C
Cross-section: 0.5 mm² - 1 mm²
... fixed plants, in distribution panels, on and under plaster as laid in conduit or on insulating support. - These cables are produced according to TS EN 50525-2-31. - Permissible operating temperature: ...
Temperature: 70 °C
Cross-section: 1.5 mm² - 10 mm²
... fixed plants, in distribution panels, on and under plaster as laid in conduit or on insulating support. These cables are produced according to TS EN 50525-2-31. - Permissible operating temperature: ...
Temperature: 70 °C
Cross-section: 1.5 mm² - 10 mm²
... fixed plants, in distribution panels, on and under plaster as laid in conduit or on insulating support. These cables are produced according to TS EN 50525-2-31. - Permissible operating temperature: ...
Nominal voltage: 600 V
Temperature: 200 °C
Draka offers a wide selection of power and signal wire, including shielded pairs, door lock wire, THHN and TEW, coax, UTP and more.
Temperature: -30 °C - 60 °C
... optimized design of high-speed cable pitch technology production process greatly improves crosstalk And the transmission performance index margin such as return loss, etc., to obtain a higher transmission bandwidth. Adopt ...
Zhaolong Interconnect
Nominal voltage: 1,800 V
Temperature: -50 °C - 700 °C
Cross-section: 0.5 mm² - 50 mm²
Single core; 1X2.5; U0/U: 300 / 500 V; Glass fibre; Fixed Installation Suitable for areas where the installation temperature and ambient temperature is very high Good electrical conductivity due to ...
Lapp France
Temperature: -65 °C - 260 °C
Cross-section: 0.5 mm²
Our automotive cables are the reliable and efficient connection for each wiring system. We offer an extensive range of products with various OEM and Tier 1 approvals. We supply both by international standards and the ...
LEONI AG
Nominal voltage: 1 kV
... =3.6kV) VV22/VLV22-0.6/1-kV-single-core - VV22/VLV22-0.6/1-kV-multi core 1. Conductor: Copper or aluminum, Class 1: solid conductor, or Class 2: stranded conductor 2. ...
Henan Tong-Da Cable Company
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining