Primary voltage: 600 V
Our Bulletin 1411 Current Transformers (CTs) are low voltage transformers for various power measurement devices and applications, including protective relays, analog devices, transducers, and PowerMonitor™ products. • Includes low ...
Frequency: 45 Hz - 65 Hz
MRC022 TRMS Current Transformer with integrated Transducers hole Ø22 Selectable input 5÷30A with passive output 4-20 mA (2 wires technology) TRMS Multirange current transformers, with loop-powered 4-20mA output (also called “passive”), ...
Secondary voltage: 0 V - 10 V
Primary current: 30, 40, 50 A
Secondary current: 0 A - 0 A
Current transformer and measuring transducer in one housing The current transformer measuring transducers of the SCMU series are suitable for measuring sinusoidal alternating currents. The input variable is galvanically isolated (5kV/1min), ...
Primary voltage: 0 V - 10 V
Primary current: 60 A - 600 A
Secondary current: 0 A - 0 A
Current transformer and measuring transducer in one housing The current transformer measuring transducers of the SCMU series are suitable for measuring sinusoidal alternating currents. The input variable is galvanically isolated (5kV/1min), ...
Primary voltage: 230, 24 V
Primary current: 10 A - 600 A
Secondary current: 4 A - 20 A
The current transformer measuring transducers of the SMU/I series are suitable for measuring sinusoidal alternating currents. The input variable is galvanically isolated (5kV/1min), rectified (averaging) and converted into a proportional, direct ...
Secondary voltage: 24 V
Primary current: 24,000 A
for the use in transducer units for surface treatment output voltage 24 V DC 24.000 A
This linear current transformer series, allow to obtain an AC or DC voltage on output without other transducer. This solution reduce the cost and space of the installation. Mechanical dimension and primary current on main characteristics ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining