- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Ultrasonic level switch
Ultrasonic level switches
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Process temperature: -40 °C - 177 °C
Process pressure: 137.8 bar
... construction, coatings, finishes or adjustable time delay and density set point. Direct Replacement for Ultrasonic Gap Switches, RF Capacitance Switches, Float Switches and Other Technologies Immune to Coating or Build-Up ...
Process temperature: -20 °C - 50 °C
... echo processing algorithms to identify the sludge interface level using state-of-the-art technology only found in this unit. Why Measure Sludge Level? Sludge blanket level control is a crucial aspect ...
Process temperature: -40 °C - 121 °C
Process pressure: 55, 103 bar
... Echotel® Model 910 ultrasonic level switches utilize ultrasonic contact technology for measuring level in clean liquid applications. These integrally mounted level switches ...
Process temperature: -40 °C - 70 °C
Process pressure: 138 bar
... for compliance with safety systems and overfill protection have mandated more reliable point level measurement. Echotel® Models 961 and 962 ultrasonic level switches meet these demands with advanced ...
Process temperature: -40 °C - 85 °C
Process pressure: 138 bar
... Echotel® Model 940 and 941 Ultrasonic Level Switches are compact integral units that utilize pulsed signal technology to perform high or low level measurement in a wide variety of liquid applications. ...
Process temperature: -20 °C - 120 °C
Process pressure: 0 bar - 10 bar
... and is integral with the rod.* One !oat can operate just one Reed (min. or max. level), or two Reeds (min. and empty and extra max. level) thus meeting the most complex needs.* Total safety ...
... Ultrasonic sensor Medium: various Max. number of switching points Level: analogue ...
Process temperature: 85 °C
... The SOLIBA tilt level switch only operates when the high level is reached, unlike other types of level measurement devices that operate permanently The tilt level ...
Process temperature: -20 °C - 70 °C
... radars, capacitive and ultrasonic sensors, etc. The SOLIBA EX P tilt level switch only operates when the high level is reached, unlike other types of level measurement ...
Process temperature: -40 °C - 70 °C
Process pressure: 1,000 psi
... for maintenance free operation • DPDT relay output Product Type Ultrasonic level sensor, Liquid level sensor, Liquid level indicator, Point level switch, ...
Process temperature: -25 °C - 120 °C
Process pressure: 16 bar
... Capacitive filling level monitor for top installation with stable stainless steel shaft and PTFE tip for adhesive media With chemical-resistant PTFE tip Robust stainless steel housing For use in medium temperatures up ...
Process temperature: 5 °C - 60 °C
... Point Level Detector (PLD) is extremely user friendly with a sleek, compact design incorporating integral electronics that never require calibration. The PLD is the most advanced non-invasive, pulse-wave ultrasonic ...
... The Sonocontrol 15 by Sonotec Ultraschallsensorik Halle GmbH is a Non-intrusive ultrasonic level switch designed to detect whether a tube is filled with liquid or liquefied gas. It features its performance ...
Process temperature: -40 °C - 105 °C
Process pressure: 0 bar - 5 bar
... reliable level switch with no moving parts. It comprises of a one piece moulded body with an integral PCB, the 003 Level Switch is factory sealed and supplied with a flying lead for customer ...
Process temperature: 5 °C - 60 °C
... Continuous Level Detector (CLD) is available in a standard configuration, as well as customized designs to meet customer application requirements. The unique pulsed, non-invasive design of this continuous level ...
Introtek
Process temperature: -20 °C - 200 °C
Process pressure: 10 bar
... The RIL250 float level switch can be used for food liquids, dirty liquids, water, petrol, refrigerant oils. It tolerates the presence of metallic particles, including ferrous ones, given that the float does not carry ...
Riels Instruments
Process temperature: -40 °C - 150 °C
Process pressure: 100 bar
... proprietary principle of distributed acoustic waves in a métal rod. If the rod is not covered by the liquid the acoustic waves are dispersed freely without any interférence. If liquid covers the rod the émission of acoustic ...
Process temperature: -20 °C - 60 °C
Process pressure: 2 bar
... The general purpose ultrasonic level sensor provides continuous level detection up to 26.2’ (8m) with 3 programmable relays for level switch or level ...
Flowline
Process temperature: -60 °C - 220 °C
... ELL® Ultrasonic Non-contact Level Switch is a redundant vibration level switch operates with “frequency ultrasonic” technology. With measurement ...
Xi'an Dinghua Electronic Technology Co., Ltd
Process temperature: -20 °C - 70 °C
... non-intrusive level switch can output relay signals to the later stage electrical appliances or other equipment, so as to realize the monitoring or control of liquid level. Applications The sonar pulse ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group