Temperature calibrator MB series
dry-blockportabledigital

temperature calibrator
temperature calibrator
temperature calibrator
temperature calibrator
temperature calibrator
temperature calibrator
temperature calibrator
Add to favorites
Compare this product
 

Characteristics

Measured physical value
temperature
Options
portable, digital, laboratory, precision, dry-block
Temperature

Max.: 700 °C
(1,292 °F)

Min.: -45 °C
(-49 °F)

Voltage

115 V, 230 V

Description

With a conventional dry block, you typically needed an external reference sensor if you wanted better accuracy. The Beamex MB has accurate internal temperature measurement and display accuracy up to ±0.1°C, so you can get high accuracy even without an external reference sensor. With its unique temperature control technology, the Beamex MB has excellent stability up to ±0.005°C Built-in high-accuracy reference input In order to receive the best accuracy from the MB, there is a possibility to connect an external reference sensor into the reference sensor connection (R model). This eliminates the need for a separate reference thermometer. The reference sensor measurement is accurate up to ±0.006 °C. ITS-90 or CVD coefficients can be used to compensate any sensor errors. Axial uniformity With the unique dual zone control and extended well depth, the Beamex MB has an excellent axial uniformity up to ±0.02 °C. Immersion Depth The Beamex MB series provides immersion depth up to 203 mm (160 mm in MB140), which, together with the control technology, provides more stable calibration. Moreover, a deeper immersion depth reduces the stem conduction error (heat loss into the atmosphere), especially at higher temperatures. Loading With the extended well depth and the dual zone temperature control feature, the Beamex MB can correct the effect of loading and provides loading Communication with Beamex MC calibrators The communication port enables communication with selected Beamex MC calibrators for automatic calibration and documentation. Combined with a Beamex MC6 calibrator, loop calibrations are possible with conventional, HART and Fieldbus temperature transmitters with sensors.

Exhibitions

Meet this supplier at the following exhibition(s):

ACHEMA 2024
ACHEMA 2024

10-14 Jun 2024 Frankfurt am Main (Germany)

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.