- Detection - Measurement >
- Electrical Measurements >
- Laboratory calibrator
Laboratory calibrators
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Temperature: -50 °C - 250 °C
Pressure: -0.85 bar - 25 bar
Voltage: 24 V
... memory Intrinsically safe version Description General information The model CPH7000 process calibrator is a precise, portable calibrator for the calibration and checking of analogue pressure measuring instruments, ...
WIKA Alexander Wiegand SE & Co. KG
Temperature: -55 °C - 200 °C
Voltage: 240 V
... plants. The portable dry well calibrators of the CTD9100 family are particularly suited for on-site calibrations and are extremely user-friendly. Due to their compact design and their low weight, the dry well calibrators ...
WIKA Alexander Wiegand SE & Co. KG
Temperature: -30 °C - 80 °C
Voltage: 24 V
... Calibration service companies and service industry Measurement and control laboratories Quality assurance Special features Measurement and simulation of the following parameters: pressure, electrical signals (mA, ...
WIKA Alexander Wiegand SE & Co. KG
... /b>
Primary-level microphone
calibration system for the calibration of
laboratory standard microphones using the reciprocity method.
Applications
- Primary (reference) calibration of laboratory
Temperature: -10 °C - 50 °C
... /b>
Type 4229 Hydrophone
Calibrator is a battery-operated sound pressure source designed for precise calibration of hydrophones and underwater sound measurement systems. The unit is portable for both field and
laboratory ...
... capable of measuring noise exposure. The uncertainty margins are provided to facilitate the accreditation needs of the laboratory (ISO 17025) and calibration reports are generated automatically to minimize the risk of human errors. Users ...
Temperature: -10 °C - 50 °C
Pressure: 25 mbar - 1,000,000 mbar
Voltage: 4 V
... area and 5x hazardous area models to satisfy budget and application requirements from a basic, electrical calibrator to a multifunction calibrator with HART, Profi Bus and Fieldbus. Can be use with pressure modules ...
Humidity range: 10 % - 95 %
... High Precision Humidity Calibrator The Humor 20 is a highly accurate, easy to use humidity calibrator and represents the ideal reference for calibration laboratories or for manufacturers of humidity ...
Voltage: 0 V - 1,020 V
... Overview
The Fluke 5560A is a multi-product
laboratory
calibrator designed to cover broad electrical workloads with high accuracy. It supports DC/AC voltage and current, resistance, capacitance, inductance and ...
Fluke Calibration
Temperature: -20 °C - 70 °C
Pressure: 0 Pa - 68,947,572.93 Pa
Voltage: 100, 110, 220 V
... The Ashcroft® PT-1 bench-top digital calibrator is used in measurement applications requiring highly accurate secondary transfer standards. The PT-1 includes one or two permanently installed pressure or temperature sensors. Key Features: Single ...
... Summary
Portable, battery-powered accelerometer
calibrators of Type 8921B are designed to verify and calibrate accelerometer sensitivity in field and
laboratory environments. The unit provides an accurate, controlled ...
Temperature: -45 °C - 700 °C
Voltage: 230, 115 V
... loading Communication with Beamex MC calibrators The communication port enables communication with selected Beamex MC calibrators for automatic calibration and documentation. Combined with a Beamex MC6 calibrator, ...
Temperature: -50 °C - 200 °C
Voltage: 100 V - 240 V
... Description
The Kaye LTR-200 is a hybrid dry-block temperature
calibrator engineered
for
laboratory and mobile thermal validation. It performs simultaneous calibration of up to 24 thermocouples ...
Kaye
Temperature: 5 °C - 40 °C
Pressure: 1.03 bar
Voltage: 100 V - 240 V
... manufactured to ISO 17025 standards at a NVLAP-accredited lab using assets that are directly traceable to NIST. Product Benefits The performance of only the highest level metrology laboratories can now be yours ...
Temperature: 0 °C - 40 °C
... FPI AQMS-200 multi-gas calibrator utilizes mass flow controller to perform standard zero and span calibration with up to 4 gas sources. Key Features • Stable trace level ozone output down to 0.1ppm; • Optional ozone generator, gas phase ...
... The stage micrometer from Opto in the form of a microscope slide is required for the calibration of microscopes.
- Glass scale 50 mm in 0.1 mm and 0.01 mm
- Calibration of measurement software
The Stage Micrometer is also available ...
... Opto's Particle Test Target allows the calibration of measurement functions in microscopes through objects in different forms and sizes or of resolution of an optical system measured in Line Pairs per mm. It is used in the field of Residual Dirt Analysis.
The ...
Temperature: -35 °C - 200 °C
... CALsys -35/200 offers easy to use liquid temperature calibrator with high temperature range from -35 °C to 200°C. It is a highly stable standard furnace for calibrating thermocouples / RTD. It provide superior thermal environment for ...
TEMPSENS
Temperature: 300 °C - 1,200 °C
... CALsys 1200L offers easy to use temperature calibrator with high temperature range from 300 to 1200°C. It is a highly stable standard furnace for calibrating thermocouples / RTD. This calibrator can be used on site for ...
TEMPSENS
Temperature: 500 °C - 1,500 °C
... Calsys 1500L offers easy to use temperature calibrator with high temperature range from 500 to 1500°C. It is a highly stable standard furnace for calibrating thermocouples / RTD. This calibrator can be used on site for ...
TEMPSENS
Temperature: -100 °C - 1,200 °C
Pressure: 0 bar - 700 bar
Humidity range: 10 % - 98 %
... Calibration certificates for sensors and measuring devices • Calibration for temperatures from -100 to +1200 °C • Calibration for humidity from 10 to 98 % r.h. at ambient temperatures from +10 to +95 °C • Calibration for flow velocities from 0.1 ...
Ahlborn Mess- und Regelungstechnik GmbH
Temperature: -100 °C - 1,200 °C
... Calibration Certificates Temperature • DAkkS accredited certificates for temperature sensors • Factory certificates for temperature sensors • Certificates with sensor deviation towards zero • DAkkS accredited certificates infrared • Factory certificates ...
Ahlborn Mess- und Regelungstechnik GmbH
Humidity range: 10 % - 98 %
... Calibration certificates relative humidity and dew point • Factory certificates for capacitive humidity sensors • DAkkS accredited certificates for capacitive humidity sensors and psychrometers • Factory certificates for capacitive humidity sensors ...
Ahlborn Mess- und Regelungstechnik GmbH
Temperature: -100 °C - 1,800 °C
... ergonomic hand housing of small dimensions and weight with rubberized non-slip side handles, simple and reliable to use laboratory banana connectors, functional keyboard, standard battery power supply (2x1,5V) or accumulators 2x1,2V ...
Voltage: 0 mV - 11,000 mV
... Universal calibrator - DIGISTANT® 4420 The DIGISTANT® model 4420 universal calibrator, built to use in the field, is ideal for checking and calibrating temperature measurement and control devices. The versatile functions ...
Voltage: 0 V - 10 V
... suited to laboratory, field and industrial use. Voltage outputs are set by selecting the range switch and dialling up the desired value on the thumbwheel switch. Output polarity can be selected using the normal/off/reverse switch. ...
Time Electronics
... instrument which is easily portable and convenient for laboratory, field, or industrial use. It incorporates many of the well-proven circuit techniques of the Time Electronics 1010 DC voltage calibrator. The null ...
Time Electronics
Pressure: 0 bar - 600 bar
... The 7010 is a robust portable pressure calibrator that is suitable for field and laboratory calibration work of both pressure and electrical process loop signals. It is a simple operation instrument ideal for calibrating ...
Time Electronics
Voltage: 0 V - 1,000 V
... Transmille have applied their expertise in designing bench and transportable calibrators to create a new generation of multifunction calibrators that offer true portability at a price that ensures rapid return on investment. On ...
TRANSMILLE
Voltage: 0 V - 1,000 V
... The 3000 series offers the widest workload coverage of any multi-product calibrator, with the ability to calibrate 18 types of instrument. It has the power to drive older analogue instruments alongside the accuracy to calibrate modern ...
TRANSMILLE
Voltage: 0 V - 1,000 V
... The 33XXA Series multiproduct calibrators are modular versions of the class leading 3000A Series Calibrators. Designed to reduce cost, the 33XXA Series feature 0 – 20V DC output as standard with a wide range of options ...
TRANSMILLE
Temperature: -220 °C - 2,310 °C
Pressure: 0 bar - 1,000 bar
Voltage: 100 mV - 50,000 mV
... CALYS 1000 is a field documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, ...
AOIP
Temperature: -250 °C - 2,310 °C
Pressure: 0 bar - 1,000 bar
Voltage: 100 mV - 50,000 mV
... CALYS 1200 is a field documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, ...
AOIP
Temperature: -220 °C - 850 °C
Pressure: 0 bar - 1,000 bar
Voltage: 100 mV - 50,000 mV
... CALYS 150 field documenting multifunction calibrator is the top instrument of the range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab ...
AOIP
Temperature: 5 °C - 40 °C
Pressure: 0 bar - 2 bar
... Product overview T2730 by ForTest® is a digital portable calibrator housed in an anodized aluminium enclosure with a shatterproof plexiglass front. It integrates a renewed electronic board and a mass flow sensor for direct leak ...
Temperature: 10 °C - 40 °C
... Horizontal Calibration Instrument for Laboratory Measuring bench for the checking of fixed and variable dimension measuring means. A top range for daily use in workshop or in laboratory. The Horizon Calibration ...
Voltage: 24 V
... High-precision handheld multimeter and process calibrator for measurement and simulation of electrical quantities. The METRACAL CM series sets the standard for mobile calibration technology. As multifunctional process calibrators ...
... inspection tasks, as well as for test department and laboratory work, in process engineering, control room and equipment fabrication, general measuring technology and many other applications. Universal calibrator, simulator mA, ...
Temperature: 5 °C - 45 °C
... resolution compared to previous CDF More than 8h battery lifetime Strong carry case Can be used for field as well as laboratory checks Accreditation of CDF flow measurement ranges to ISO 17025 possible as an option SPECIFICATIONS Physical ...
Temperature: 0 °C - 60 °C
Pressure: 500 Pa - 2,000,000 Pa
... The CDP60 calibrator checks the pressure calibration of leak and flow measurement instruments as well as any other pressure measuring instrument. This light, compact and user friendly calibrator is essential for field ...
Temperature: -20 °C - 50 °C
Voltage: 0 V - 24 V
... PLC programmers, maintenance technicians, technical assistance companies, measurement laboratories, device control and calibration activities, electronics laboratories, electromechanical workshops, and quality control ...
Temperature: -20 °C - 50 °C
Pressure: -14.5 psi - 10,000 psi
Voltage: 0 V - 28 V
... This flexibility allows users to customize their calibrator to meet specific needs, adding to its versatility. • Measure and Sink mA and V with High Accuracy: The HPC50 isn't just a pressure calibrator but also a high-accuracy ...
Ametek Calibration
Temperature: -45 °C - 165 °C
... The RTCt temperature calibrator represents a leap forward in usability and flexibility. Building on the success of the RTC, the new RTCt model brings user-friendly advancements like a larger, customizable touchscreen display, dual sensor ...
Ametek Calibration
Temperature: -20 °C - 50 °C
Pressure: -14.5 psi - 15,000 psi
Voltage: 0 V - 30 V
... When precision matters, the HPC40 Series handheld pressure calibrator is the tool you need. As the world’s first combined pressure and mA loop calibrator to be fully temperature compensated from -20 to 50°C, the HPC40 ...
Ametek Calibration
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group