Flue gas analyzer MS400-VOC
exhaust gastoxic gasmethane

Flue gas analyzer - MS400-VOC - Beijing Zetron Technology Co., Ltd. - exhaust gas / toxic gas / methane
Flue gas analyzer - MS400-VOC - Beijing Zetron Technology Co., Ltd. - exhaust gas / toxic gas / methane
Add to favorites
Compare this product

Characteristics

Measured entity
oxygen, carbon dioxide, flue gas, CO, methane, exhaust gas, toxic gas
Application domain
for monitoring gas emissions, for ambient air, for the chemical industry, for pharmaceutical products, for environmental assessments, for the petroleum industry
Measured value
concentration, humidity, temperature, thermal conductivity
Configuration
handheld, compact
Mode of use
automatic
Technology
infrared, electrochemical
Detector type
PID
Protection level
waterproof
Other characteristics
multi-parameter, continuous, data acquisition, with data logger, simultaneous, volatiles, intrinsically safe, battery-powered, multi-channel, high-temperature, with oxygen sensor, with CO2/O2 sensor, high-definition, four-channel, multichannel

Description

Product overview
The Zetron handheld VOC gas analyzer provides configurable alarm modes (sound, light, vibration) and multidirectional visual indicators for rapid detection. It combines sound & light, vibration and screen visual alarms to suit varied industrial environments.

Series / additional description
The MS400 series is a compact, lightweight handheld platform capable of continuous monitoring and display of up to 4 gas concentrations. The page references model MS600‑VOC as presented; MS400 series details apply for configurable multi‑gas detection and modular sensor options.

Parameters
Gases to be detected: arbitrary combination of 1–6 gas types (toxic gases, O2, CO2, flammable/explosive gases, TVOC, etc.). Optional: temperature and humidity measurement.
Application scenarios: portable rapid detection in oil & gas, chemical, pharmaceutical, environmental monitoring, combustion gas distribution, warehousing, smoke/flue gas analysis, air quality governance and similar use cases.
Detection ranges: selectable ranges including 0–1, 10, 100, 1000, 5000, 50000, 100000 ppm; 200 mg/L; 100% LEL; 20%, 50%, 100% Vol; other ranges customizable.
Resolution examples: 0.001 ppm (0–10 ppm); 0.01 ppm (0–100 ppm); 0.1 ppm (0–1000 ppm); 1 ppm (0–10000 ppm+); 0.01 mg/L (0–200 mg/L); 0.1%/0.01% LEL; 0.001% Vol.
Detection principles: electrochemical, catalytic combustion, infrared, thermal conductivity, PID (photoionization) — selected by gas type, range and field environment.
Sensor service life: electrochemical 2–3 years; oxygen sensor 2 or 6 years selectable; infrared 5–10 years; catalytic 3 years; thermal conductivity 5 years; PID 2–3 years.
Accuracy & performance: allowable error ≤ ±1% F.S (other precision levels customizable). Linearity, repeatability, uncertainty ≤ ±1% each.
Response & recovery: T90 ≤ 20 s; recovery ≤ 30 s.
Working environment: temperature -40 ℃ to +70 ℃; humidity 10–95% RH (built‑in filters for high humidity/high dust environments).
Sample gas temperature: -40 ℃ to +70 ℃; optional high‑temperature sampling and cooling filter handle for smoke/gas up to 1300 ℃.
Temperature & humidity measurement (optional): temperature -40 ℃ to +70 ℃ (accuracy 0.5 ℃); humidity 0–100% RH (accuracy 3% RH).
Power supply: 3.6 VDC, 6000 mAh rechargeable polymer battery.
Display: 2.5‑inch high‑definition color screen.
Detection mode: built‑in pump (suction) with flow 500 ml/min (calibration flow > 500 ml/min); three‑way tubing for bypass discharge of excess gas.
Alarm modes: configurable — sound & light, vibration, sound & light + vibration, or alarm off.
Communication interfaces: USB (charging and data); optional RS232, infrared, automatic recognition.
Data storage: standard up to 100,000 entries; SD card optional.
Protection & certification: IP67 ingress protection; intrinsically safe explosion protection (Exia II CT6).
Dimensions & weight: 180 × 78 × 33 mm (L × W × H); 350 g.
Standard accessories: manual, qualification certificate, warranty card, USB charger with data cable, aluminium instrument case, belt clip, humidity/dust filter.

Technical specifications
  • Brand: Zetron
  • Model shown on page: MS600‑VOC (MS400 series referenced)
  • Detectable gases: configurable 1–6 gases; library >500 gas types
  • Detection principles: electrochemical, catalytic combustion, IR, thermal conductivity, PID
  • Detection ranges & resolutions: selectable from sub‑ppm to 100000 ppm, mg/L, %LEL, %Vol (customizable)
  • Response time T90: ≤ 20 s; Recovery: ≤ 30 s
  • Operating temperature: -40 ℃ to +70 ℃; sample gas up to 1300 ℃ with options
  • Battery: 3.6 VDC, 6000 mAh rechargeable polymer
  • Display: 2.5" color HD
  • Interfaces: USB standard; RS232/IR optional
  • Data storage: 100,000 entries (SD optional)
  • Ingress protection: IP67
  • Explosion protection: Intrinsically safe, Exia II CT6
  • Dimensions / Weight: 180×78×33 mm / 350 g
  • Accessories: manual, certificates, USB charger, aluminium case, belt clip, filters

Catalogs

No catalogs are available for this product.

See all of Beijing Zetron Technology Co., Ltd.‘s catalogs

Other Beijing Zetron Technology Co., Ltd. products

Portable Gas Detectors

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.