Product overviewThe Zetron handheld VOC gas analyzer provides configurable alarm modes (sound, light, vibration) and multidirectional visual indicators for rapid detection. It combines sound & light, vibration and screen visual alarms to suit varied industrial environments.
Series / additional descriptionThe MS400 series is a compact, lightweight handheld platform capable of continuous monitoring and display of up to 4 gas concentrations. The page references model MS600‑VOC as presented; MS400 series details apply for configurable multi‑gas detection and modular sensor options.
ParametersGases to be detected: arbitrary combination of 1–6 gas types (toxic gases, O2, CO2, flammable/explosive gases, TVOC, etc.). Optional: temperature and humidity measurement.
Application scenarios: portable rapid detection in oil & gas, chemical, pharmaceutical, environmental monitoring, combustion gas distribution, warehousing, smoke/flue gas analysis, air quality governance and similar use cases.
Detection ranges: selectable ranges including 0–1, 10, 100, 1000, 5000, 50000, 100000 ppm; 200 mg/L; 100% LEL; 20%, 50%, 100% Vol; other ranges customizable.
Resolution examples: 0.001 ppm (0–10 ppm); 0.01 ppm (0–100 ppm); 0.1 ppm (0–1000 ppm); 1 ppm (0–10000 ppm+); 0.01 mg/L (0–200 mg/L); 0.1%/0.01% LEL; 0.001% Vol.
Detection principles: electrochemical, catalytic combustion, infrared, thermal conductivity, PID (photoionization) — selected by gas type, range and field environment.
Sensor service life: electrochemical 2–3 years; oxygen sensor 2 or 6 years selectable; infrared 5–10 years; catalytic 3 years; thermal conductivity 5 years; PID 2–3 years.
Accuracy & performance: allowable error ≤ ±1% F.S (other precision levels customizable). Linearity, repeatability, uncertainty ≤ ±1% each.
Response & recovery: T90 ≤ 20 s; recovery ≤ 30 s.
Working environment: temperature -40 ℃ to +70 ℃; humidity 10–95% RH (built‑in filters for high humidity/high dust environments).
Sample gas temperature: -40 ℃ to +70 ℃; optional high‑temperature sampling and cooling filter handle for smoke/gas up to 1300 ℃.
Temperature & humidity measurement (optional): temperature -40 ℃ to +70 ℃ (accuracy 0.5 ℃); humidity 0–100% RH (accuracy 3% RH).
Power supply: 3.6 VDC, 6000 mAh rechargeable polymer battery.
Display: 2.5‑inch high‑definition color screen.
Detection mode: built‑in pump (suction) with flow 500 ml/min (calibration flow > 500 ml/min); three‑way tubing for bypass discharge of excess gas.
Alarm modes: configurable — sound & light, vibration, sound & light + vibration, or alarm off.
Communication interfaces: USB (charging and data); optional RS232, infrared, automatic recognition.
Data storage: standard up to 100,000 entries; SD card optional.
Protection & certification: IP67 ingress protection; intrinsically safe explosion protection (Exia II CT6).
Dimensions & weight: 180 × 78 × 33 mm (L × W × H); 350 g.
Standard accessories: manual, qualification certificate, warranty card, USB charger with data cable, aluminium instrument case, belt clip, humidity/dust filter.
Technical specifications- Brand: Zetron
- Model shown on page: MS600‑VOC (MS400 series referenced)
- Detectable gases: configurable 1–6 gases; library >500 gas types
- Detection principles: electrochemical, catalytic combustion, IR, thermal conductivity, PID
- Detection ranges & resolutions: selectable from sub‑ppm to 100000 ppm, mg/L, %LEL, %Vol (customizable)
- Response time T90: ≤ 20 s; Recovery: ≤ 30 s
- Operating temperature: -40 ℃ to +70 ℃; sample gas up to 1300 ℃ with options
- Battery: 3.6 VDC, 6000 mAh rechargeable polymer
- Display: 2.5" color HD
- Interfaces: USB standard; RS232/IR optional
- Data storage: 100,000 entries (SD optional)
- Ingress protection: IP67
- Explosion protection: Intrinsically safe, Exia II CT6
- Dimensions / Weight: 180×78×33 mm / 350 g
- Accessories: manual, certificates, USB charger, aluminium case, belt clip, filters