Sampling probe HSP12
gas samplinggasflue gas

Sampling probe - HSP12 - Beijing Zetron Technology Co., Ltd. - gas sampling / gas / flue gas
Sampling probe - HSP12 - Beijing Zetron Technology Co., Ltd. - gas sampling / gas / flue gas
Add to favorites
Compare this product

Characteristics

Type
sampling, gas sampling
Measured value
gas, oxygen, flue gas
Applications
for high-temperature applications
Domain
for environmental analysis, for industrial applications, for gas analysis, for process monitoring
Other characteristics
with handle, cooled
Insertion length

1,200 mm
(47.2 in)

Description

Product overview
Zetron HSP12 flue gas sampling probe designed for industrial engines and high‑temperature sampling applications. Compatible with PTM600-FG detectors; optional high‑temperature sampling handle with cooling filter enables detection of flue gas up to 1200 ℃. Probe and accessories are configured for inline sampling with pre‑filtration and process monitoring functions.

Detected gases — Range / Accuracy / Resolution / Response time T90
Gases to be detected | Range | Accuracy | Resolution | Response time T90
Combustible gas (EX) | 0-100%LEL | <±2%(F.S) | 0.1%LEL | ≤10 seconds
Methane (CH4) | 0-100%Vol | <±2%(F.S) | 0.1%Vol | ≤10 seconds
Oxygen (O2) | 0-30%Vol | <±2%(F.S) | 0.01%Vol | ≤10 seconds
Hydrogen sulfide (H2S) | 0-100ppm | <±2%(F.S) | 0.01ppm | ≤30 seconds
Sulfur dioxide (SO2) | 0-100ppm | <±2%(F.S) | 0.01ppm | ≤30 seconds
Nitric oxide (NO) | 0-100ppm | <±2%(F.S) | 0.01ppm | ≤30 seconds
Ethylene oxide (ETO) | 0-100ppm | <±2%(F.S) | 0.01ppm | ≤30 seconds
Phosgene (COCl2) | 0-1ppm | <±2%(F.S) | 0.001ppm | ≤20 seconds
Silane (SiH4) | 0-50ppm | <±2%(F.S) | 0.01ppm | ≤30 seconds

Applications
  • Petroleum industry
  • Chemical plants
  • Pharmaceutical manufacturing
  • Environmental monitoring and emissions control
  • Gas distribution facilities
  • Flue gas analysis and combustion diagnostics
  • Air treatment systems
  • Any industrial process requiring gas concentration detection and sampling


Technical features / specifications
  • Model: Zetron HSP12
  • Compatibility: designed for integration with PTM600-FG detector; optional high‑temperature sampling handle with cooling filter for detection up to 1200 ℃
  • Probe: 1200 mm length, rated for 1000 ℃ (1200 ℃ detection possible with optional configuration)
  • Cooling hose: 1000 mm
  • Filtration: water filter and dust filter included (cooling filter handle available)
  • Functions: pressure and temperature measurement for process monitoring
  • Gas measurement performance: see detected gases table for range, accuracy, resolution and T90

Catalogs

No catalogs are available for this product.

See all of Beijing Zetron Technology Co., Ltd.‘s catalogs

Other Beijing Zetron Technology Co., Ltd. products

Portable Gas Detectors

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.