ProductZetron HSP8 flue gas sampling filter probe compatible with PTM600-FG. The PTM600-FG detector can be optionally configured with a high-temperature sampling and cooling filter handle to sample flue gas up to 800 ℃. Standard supply includes an 800 mm probe rated for 800 ℃, a 1000 mm cooling hose, water and dust filters, and pressure & temperature measurement functions.
Detection TableGases to be detected | Range | Accuracy | Resolution | Response time T90Combustible gas (EX) | 0-100%LEL | <±2% (F.S) | 0.1%LEL | ≤10 seconds
Methane (CH4) | 0-100%Vol | <±2% (F.S) | 0.1%Vol | ≤10 seconds
Oxygen (O2) | 0-30%Vol | <±2% (F.S) | 0.01%Vol | ≤10 seconds
Hydrogen sulfide (H2S) | 0-100ppm | <±2% (F.S) | 0.01ppm | ≤30 seconds
Sulfur dioxide (SO2) | 0-100ppm | <±2% (F.S) | 0.01ppm | ≤30 seconds
Nitric oxide (NO) | 0-100ppm | <±2% (F.S) | 0.01ppm | ≤30 seconds
Ethylene oxide (ETO) | 0-100ppm | <±2% (F.S) | 0.01ppm | ≤30 seconds
Phosgene (COCl2) | 0-1ppm | <±2% (F.S) | 0.001ppm | ≤20 seconds
Silane (SiH4) | 0-50ppm | <±2% (F.S) | 0.01ppm | ≤30 seconds
Application- Petroleum and petrochemical plants
- Chemical industry
- Pharmaceutical manufacturing
- Environmental monitoring and protection
- Gas distribution networks
- Flue gas analysis and boiler stacks
- Air treatment systems
- Any industrial site requiring gas concentration detection and analysis
Technical specifications- Model: Zetron HSP8 (sampling filter probe)
- Compatible detector: PTM600-FG (optional high-temperature sampling & cooling filter handle)
- Probe length: 800 mm; rated to 800 ℃
- Cooling hose length: 1000 mm
- Filters: integrated water and dust filter
- Additional functions: pressure and temperature measurement
- Detection performance per gas: see Detection Table (range, accuracy, resolution, T90)