Daygas brings together efficient, economical, quality and functional products that give importance to innovation and R&D studies, thus saving energy in the heating sector, with final consumers.
- Cooling mode.
- Quick start-up.
- Silent operation.
- Low emission ratio.
- High level of safety.
- Safe gas valve system.
- Low energy consumption.
- 5-stage with thermostats or remote control
- Notification of fault and stage on the display screen.
- Custom design boiler construction for enhanced productivity.
Capacity: 16kW
Gas Consumption: NG 1.52m³/h / LPG 1.12kg/h
Dimensions: 600h / 525L / 675w
Weight: Net 39.00kg / Gross 43.00kg
Working Pressure: NG 21-55mbr / LPG 32-55mbr
Heating Area: min 80m² / avg 100m² / max 120m²
Heating Area: min 240m³ / avg 300m³ / max 360m³
Sound Level In Empty Space: 50 d-BA
Sound Level In Workplace: 39 d-BA
Flow m³: 3300m³
Electrical Connection (EU): 190-260 V / 50-60 Hz
Gas Consumption: G ¾’’
Homogeneous Heat Dissipation
Lodos hot air generators heat the area where direct conventions are required with a technological burner structure that releases minimal waste gas. Heat generated in blades with increased efficiency, an axial fan they are the most homogeneous heat dissipation devices since they are transferred directly to the media.
Space - Saving Design
Lodos hot air generators are the devices that provide heating of the heat energy from NG or LPG, either directly to the environment on which the fan is fitted, or by blowing hot air through the air ducts. The Daygas Lodos hot air generator devices provide high efficiency and low energy consumption thanks to a specially designed boiler structure. The special design is the lowest operating sound with a boiler and body structure. He works quieter than his counterparts. Due to the rise of the heating air, it is recommended that hot air generators be used in confined spaces that do not exceed ceiling height 5m to provide more efficient and homogeneous heating.
- The ability to work Hermatic and semi-hermatic.
- Electrical components consist of high heat resistant nonflammable silicone cables.
- All metal components are high temperature resistant long life aluminum-silicon alloy.
Device Controls
- Remote control.
- Integration via control board.
- Pako switched manual control.
- Thermostat-switched automatic control.
- Integration into the automation system. (Control via Scada)
The variety of control scenarios offered as 5 different alternatives allows the products to be managed correctly and in a desired way. The most appropriate control scenario is selected by evaluating the on-site use of the devices in our product range and the site conditions. Therefore, the control with the right solution scenario facilitates both fuel savings and long-lasting trouble-free service.
Integration to Automation System (Control over Scada)
Our devices can be integrated directly into building automation systems (bms) via modbus communication protocol via RS485 port (internal), or if there is no bms system available, the control of the devices can be used fully automatically from a single center via HMI touch panel or a PC.
In the BMS System:
- Operation order of the devices on the specified days and hours,
- Operation of the heaters with regional or individual step and modulation control,
- Seeing the fault codes from the devices in the system and which device is the problem and keeping it in memory,
- Functional controls such as instant, daily, weekly or monthly monitoring of fuel consumption are the advantages of the automation integrated system.
Control Panel
- Password protection.
- Heat preservation mode.
- Freeze protection feature.
- 24/7 programmable feature.
- 128 x 64 graphic LCD display.
- Communication port with computer.
- Possibility of automatic and manual control.
- Ability to connect external temperature sensor.
- Possibility to control 8 independent zones and 32 devices in total.
It makes your work easier thanks to many commands, from the command to turn the devices on and off on the working days and at the time intervals you want, to keep the environment warm in the temperature range determined for freezing protection when the business is closed.
Analog Room Thermostat
Daygas analog room thermostat automatically turns off the device when the temperature value you have set is approached, and then when the ambient temperature drops below the desired temperature value, the device automatically switches on at the maximum level and starts working again. In this way, it saves fuel.
Temperature Sensor
- Freeze protection mode.
- Possibility of modulating control.
- Temperature adjustment via the device.
When your devices approach the temperature you programmed with the Daygas temperature sensor, it provides fuel saving by reducing the modulation value of the device according to the weather conditions. When the environment reaches the desired temperature value, the device automatically shuts down, and then when it falls below the desired value, the device automatically switches on at the temperature level most suitable for the environment and starts working again.
Pako Switched Manual Control
With pako switched control, step adjusted manual control can be provided over the pako. For more local solutions where there is no control panel or it is not needed, the devices can be operated at the desired level via the paco switch. The heaters can be controlled with an independent step setting. Since the device is not powered on stand-by (0) position on the Pako, the device to be turned off goes to sleep after the closing procedures and thus long service life of the devices is ensured.
Remote Control
Daygas remote controls are simple-to-use control devices with 3 buttons and easy functions. Thanks to the Daygas remote control, all functions of the device such as on-off, heat setting up-down and reset can be easily controlled. All Daygas products can be controlled remotely with a single remote.
Technical Specifications / Features
- Capacity: 16kW
- Gas Consumption: NG 1.52m³/h / LPG 1.12kg/h
- Dimensions: 600h / 525L / 675w
- Weight: Net 39.00kg / Gross 43.00kg
- Working Pressure: NG 21-55mbr / LPG 32-55mbr
- Heating Area: min 80m² / avg 100m² / max 120m²
- Heating Area: min 240m³ / avg 300m³ / max 360m³
- Sound Level In Empty Space: 50 d-BA
- Sound Level In Workplace: 39 d-BA
- Flow: 3300m³
- Electrical Connection (EU): 190-260 V / 50-60 Hz
- Gas Connection: G ¾’’