TEST PURPOSE
This machine is designed according with the requirements of various battery short-circuit test standards. According to the standard, the short-circuit device must meet the internal resistance of 80 ± 20mΩ to obtain the maximum short-circuit current required by test. In addition, the circuit design of the short-circuit device must also be able to withstand large currents impact.
We chose industrial-grade DC electromagnetic contactors, all-copper terminals, and internal copper plates to guide the flow. The wide and thick copper plates effectively improve the heat dissipation effect, make the high current short-circuit device safer, effectively reduce the loss of test equipment, and ensure the test data Accuracy.
TEST STANDARD
IEC62133; UL 1642:2012; UN38.3
STANDARD FEATURES
Item:Specification
Internal Dimension:500*500*500mm(W*D*H)
External Dimension:700*800*1530mm(W*D*H)
Internal Material:SUS201 stainless steel plate, 1.2mm thick and affixed with Teflon;
External Material:Paint treatment of cold-rolled steel sheet,1.5mm
Observe Window:250*250mm
Exhaust port:Diameter 100mm
Pressure relief port :200*200mm
Testing Hole:There are two testing hole diameter 50mm, for cable connect.
Control Mode:Key Type
Temperature collection range:RT-1000℃
Temperature Acquisition Channel:Channel 1
Temperature Display Accuracy:±0.5℃
Voltage collection range:0-100V
Voltage Acquisition Channel:Channel 1
Voltage Display Accuracy:±0.5%
Maximum Short-circuit Current:1000A
Current Acquisition Channel:Channel 1
Current Display Accuracy:±0.5%
Internal Resistance of
Device Loop:80±20mΩ
Voltage:Single Phase 220V
Machine Weight:85kg