Class C pyranometer SR05-D1A3
analogModbusRS-485

Class C pyranometer - SR05-D1A3 - Hukx - analog / Modbus / RS-485
Class C pyranometer - SR05-D1A3 - Hukx - analog / Modbus / RS-485
Class C pyranometer - SR05-D1A3 - Hukx - analog / Modbus / RS-485 - image - 2
Class C pyranometer - SR05-D1A3 - Hukx - analog / Modbus / RS-485 - image - 3
Add to favorites
Compare this product

Characteristics

IEC 61724-1
class C
Output signal
RS-485, analog, voltage output, Modbus
Options
ISO 9060, spectrally flat, digital, thermopile

Description

Overview
The SR05-D1-A3 is an affordable spectrally flat Class C pyranometer designed for reliable measurement of global solar irradiance in PV monitoring systems, agricultural meteorology, and meteorological networks. Combining a thermopile sensing element with both digital and millivolt analog outputs, the SR05-D1-A3 offers easy integration, straightforward installation, and high performance for cost-effective PV monitoring systems.

Key features
• Class A performance: fully compliant with ISO 9060:2018 Class A classification and IEC 61724-1 requirements for Class A PV monitoring systems.
• Dual-output design: provides both Modbus RTU communication over RS-485 and a 0 to 1 V analog output for flexible system integration.
• Easy installation and leveling: features an integrated bubble level with optional ball-leveling and tube-mount accessories for simplified field installation.
• Affordable pricing: budget-conscious Class C performance for large networks.

Applications
• General solar radiation measurements.
• (Agro-)Meteorological networks.
• IEC 61724-1 Class B plane of array irradiance in commercial-scale PV system performance monitoring.
• IEC 61724-1 Class A reflected radiation in utility-scale PV system performance measurement.

Specifications
• Measurand: Global solar irradiance [W/m²]
• Sensor classification: ISO 9060:2018 spectrally flat Class C pyranometer
• Measurement range: 0 to 2000 W/m²
• Temperature response (-10 °C to +40 °C): < ±3 %
• Operating temperature range: -40 °C to +80 °C
• Calibration uncertainty: 2.4 % (k = 2)
• Electrical operating voltage: 5 to 30 VDC
• Communication protocol: MODBUS RTU over RS-485
• Analog output: 0-1 V
• Recommended calibration interval: < 2 years

Cable length options
• No cable
• 3 m
• 10 m
• 20 m

Catalogs

No catalogs are available for this product.

See all of Hukx‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.