Product OverviewThe TA0180KA 180 kHz ultrasonic transducer is designed for short-range non-contact distance measurement with a detection range of 0.1–2 m and a blind zone of less than 0.1 m. It is intended for compact position sensing, approach measurement, obstacle detection and industrial distance detection systems.
Key Features- 0.1–2 m distance measurement: Supports short-range ultrasonic detection from 0.1 m to 2 m for compact non-contact sensing applications.
- 180 kHz ultrasonic frequency: 180 kHz ±4% center frequency for high-frequency ultrasonic measurement.
- Narrow 7° beam angle: 7° ±1° full beam angle (-3 dB) for focused detection and narrow directivity.
- Short blind zone: Blind zone less than 0.1 m, enabling measurements closer than typical lower-frequency models.
- PBT housing: Compact PBT enclosure for installation in constrained spaces.
- IP65 protection level: Dust-tight and protected against water jets for practical industrial environments.
- Tested at 25°C: Performance values referenced at 25°C; integration should consider operating conditions.
Technical SpecificationsModel: TA0180KA
Center Frequency: 180 kHz ±4%
Overall Sensitivity: >100 mV (0 dB = 250 Vp-p, cycle: 50, distance: 30 cm, transmitter and receiver)
Detect Range: 0.10–2 m
Blind Zone: <0.10 m
Beam Angle: 7° ±1° (-3 dB full angle)
Static Capacitance: 450 pF ±20%
Minimal Parallel Impedance: 350 Ω ±30%
Maximum Operating Voltage: <500 V (pulse duty cycle ratio 2%)
Working Temperature: -20°C to +70°C
Protection Level: IP65
Housing Material: PBT
Typical Applications- Short-range distance measurement
- Position detection
- Approach measurement
- Obstacle detection
- Compact industrial sensing
- Automation equipment
- Narrow-beam ultrasonic detection
Mechanical DesignThe TA0180KA features a compact PBT housing with a circular sensing face, cable outlet and short body depth. Dimensional references: front diameter ≈ Φ28 mm, body depth ≈ 13 mm, cable length ≈ 400 mm — suitable for constrained installations.
Electrical and Test InformationSpecifications include admittance curve, overall sensitivity test and pointing angle curve. Overall sensitivity condition: 0 dB = 250 Vp-p, cycle: 50, 30 cm test distance using transmitter and receiver configuration. Performance values were measured at 25°C; actual integration should consider installation, temperature, target material and acoustic environment.
Technical data / specifications- Model: TA0180KA
- Detect Range: 0.10–2 m
- Blind Zone: <0.10 m
- Center Frequency: 180 kHz ±4%
- Beam Angle: 7° ±1° (-3 dB full angle)
- Static Capacitance: 450 pF ±20%
- Minimal Parallel Impedance: 350 Ω ±30%
- Maximum Operating Voltage: <500 V (pulse duty cycle ratio 2%)
- Working Temperature: -20°C to +70°C
- Protection Level: IP65
- Housing Material: PBT
- Overall Sensitivity Test Condition: 0 dB = 250 Vp-p, cycle: 50, test distance: 30 cm (transmitter & receiver)