Product OverviewThe TA0112KA is a compact 112 kHz ultrasonic transducer engineered for short-range non-contact distance measurement. It provides a detection range of 0.2–4 m with a blind zone <0.2 m and is suitable for position sensing, approach measurement, obstacle detection and compact industrial distance systems. Key acoustic and mechanical parameters include 112 kHz ±4% central resonance frequency, 8 kHz bandwidth, 14° ±2° beam angle, IP65 protection and an ABS housing.
Key Features- Detection range: 0.2–4 m (short-range ultrasonic detection)
- Central resonance frequency: 112 kHz ±4%
- Bandwidth: 8 kHz
- Beam angle: 14° ±2° (focused directional detection)
- Blind zone: <0.2 m (low blind zone)
- Housing: ABS compact housing
- Protection: IP65 (dustproof and water-resistant)
- Performance values tested at 25 °C
Technical Specifications- Model: TA0112KA
- Central resonance frequency: 112 kHz ±4%
- Bandwidth: 8 kHz
- Comprehensive sensitivity: -60 dB min, 0 dBN (200 Vp-p, 50 periods, 20 cm)
- Detection distance: 0.20–4 m
- Blind zone: <0.20 m
- Transmitting beam angle: 14° ±2° (-3 dB full open angle)
- Electrostatic capacity: 1200 pF ±20%
- Minimum parallel impedance: 250 Ω ±30%
- Maximum working voltage: <500 V (pulse, 2% duty)
- Working temperature: -20 °C to +70 °C
- Protection level: IP65
- Housing material: ABS
Typical Applications- Short-range distance measurement
- Position location and compact position sensing
- Approach measurement and presence detection
- Obstacle detection and collision avoidance
- Compact industrial sensing modules
- Automation equipment integration
- Short-range level measurement
Mechanical DesignThe sensor uses a compact ABS housing with a circular sensing face and cable outlet, designed for installations with limited space. Approximate dimensions: front diameter Φ25 mm, inner diameter Φ20 mm, body depth 12 mm. Mechanical layout supports embedded mounting and straightforward cable routing.
Electrical and Test InformationSpecification and performance data include frequency-total resistance, frequency-phase angle, pointing angle and sensitivity curves. Sensitivity test condition: 200 Vp-p transmitting voltage, 50 periods, 20 cm test distance. Performance values are measured at 25 °C; integration must consider actual installation conditions, temperature, target material and acoustic environment.
Why Choose the TA0112KAA compact 112 kHz ultrasonic distance sensor offering a short blind zone, focused 14° beam angle, IP65 protection and ABS housing for reliable short-range non-contact measurement where higher-frequency ultrasonic operation is required.
Summary specifications- Model: TA0112KA
- Detection distance: 0.20–4 m
- Blind zone: <0.20 m
- Central resonance frequency: 112 kHz ±4%
- Bandwidth: 8 kHz
- Transmitting beam angle: 14° ±2°
- Comprehensive sensitivity: -60 dB min (200 Vp-p, 50 periods, 20 cm)
- Electrostatic capacity: 1200 pF ±20%
- Minimum parallel impedance: 250 Ω ±30%
- Working temperature: -20 °C to +70 °C
- Protection level: IP65
- Housing material: ABS