Oxygen transmission rate tester S401
paper and cardboardfor filmfor metal sheets

Oxygen transmission rate tester - S401 - Jinan Saicheng Electronic Technology Co.,LTD - paper and cardboard / for film / for metal sheets
Oxygen transmission rate tester - S401 - Jinan Saicheng Electronic Technology Co.,LTD - paper and cardboard / for film / for metal sheets
Oxygen transmission rate tester - S401 - Jinan Saicheng Electronic Technology Co.,LTD - paper and cardboard / for film / for metal sheets - image - 2
Oxygen transmission rate tester - S401 - Jinan Saicheng Electronic Technology Co.,LTD - paper and cardboard / for film / for metal sheets - image - 3
Add to favorites
Compare this product

Characteristics

Test type
for oxygen transmission rate
Tested product
for film, for metal sheets, paper and cardboard
Applications
laboratory, for pharmaceutical applications, for the electronics industry
Other characteristics
automatic, with touchscreen

Description

The S401 Oxygen Transmission Rate Tester is manufactured based on the coulometric sensor method and is applicable to test the oxygen permeability of medium and high barrier materials such as plastic films, composite films, sheets, papers, and other packaging materials used in food, pharmaceutical, medical device, consumer products, and electronic industries, etc.Product Features:7-inch color touchscreen with graphical user interface (GUI).This instrument is designed and manufactured according to the coulometric sensor method and meets the requirements of ASTM D3985.High-precision coulometric sensors ensure high accuracy and repeatability of the OTR measurement system.The high-precision temperature control system (optional) can precisely regulate temperature within the range of 10°C to 60°C, with an accuracy of up to ±0.1°C.A reference film for fast calibration ensures accurate and universal test data (optional).The instrument is equipped with SAICHENG's latest operating software, featuring a user-friendly interface, intelligent data processing, strict user management, secure data storage, electronic signature, etc.Equipped with micro-printer and standard USB interface.Test Principle:The pre-conditioned specimen is clamped in the test cell, oxygen or air flows on one side of the specimen while a stream of high-purity nitrogen flows on the other side. Oxygen molecules permeate through the specimen into the nitrogen side and are carried to the coulometric sensor. The sensor analyzes the oxygen concentration and calculates the oxygen transmission rate and other factors.Test Standards:This test instrument conforms to many national and international standards: DIN 53380-3, JIS K7126-2-B, GB/T 19789, GB/T 31354, YBB 00082003-2015.Applications:Basic Applications: Including plastic films, plastic composite films, paper-plastic composite films, geomembranes coextruded films, aluminized films, aluminum foils, aluminum foil composite films, and many others.Extended Applications: Including plastic bottles, pouches, coated paper cartons, vacuum bags, metal three-piece cans, plastic packages for cosmetics, soft tubes for toothpaste, jelly and yogurt cups.Test Parameters:SpecificationTest Range0.05 ~ 200 cm/(m·day) (Standard) 0.05 ~ 28,800 cm/(m·day) (Optional) (Standard area 50 cm)Resolution0.001 cm/(m·day)Temperature Range10 ~ 60°CTemperature Accuracy±0.1°CSpecificationTest Range0.00025 ~ 1 cm/(pkg·day) (Standard) 0.00025 ~ 144 cm/(pkg·day) (Optional)Resolution0.0001 cm/(pkg·day)Temperature RangeAmbient ~ 60°C (Optional)Temperature Accuracy±0.1°CTechnical Specifications:ItemsNumber of Specimen1Sample Size97 mm x 97 mm (customization is available)Sample Thickness≤3 mmTest Area50 cmTest Gas99.5% Oxygen (out of supply scope)Carrier Gas99.999% Nitrogen (out of supply scope)Port Size1/8-inch Metal TubingInstrument Dimension370 mm (W) × 700 mm (D) × 300 mm (H)Power SupplyAC 100-240V 50/60Hz (can be changed to local requirement)Net Weight36 kgConfigurations:Instrument, Micro Printer, Professional Software, Network Cable, Diamond-shaped Sampler, Vacuum Grease, 1/8-inch Metal Tubing, Nitrogen Pressure Reducing ValveComputer, Reference Film, Oxygen Pressure Reducing Valve, Container Testing Device, Container Temperature Control Device1. The gas supply port of the instrument is 1/8-inch Metal Tubing; 2. The oxygen supply port is Φ4 mm PU tubing; 3. Customers will need to prepare for gas supply.Number of Specimen: 1Sample Size: 97 mm x 97 mm (customization is available)Sample Thickness: ≤3 mmTest Area: 50 cmTest Gas: 99.5% Oxygen (out of supply scope)Carrier Gas: 99.999% Nitrogen (out of supply scope)Port Size: 1/8-inch Metal TubingInstrument Dimension: 370 mm (W) × 700 mm (D) × 300 mm (H)Power Supply: AC 100-240V 50/60Hz (can be changed to local requirement)Net Weight: 36 kg

Other Jinan Saicheng Electronic Technology Co.,LTD products

Oxygen Transmission Rate / OTR Tester

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.