Laser diffraction particle size analyzer Winner319A
opticallaserfor quality control

Laser diffraction particle size analyzer - Winner319A - JINAN WINNER PARTICLE INSTRUMENT STOCK COMPANY - optical / laser / for quality control
Laser diffraction particle size analyzer - Winner319A - JINAN WINNER PARTICLE INSTRUMENT STOCK COMPANY - optical / laser / for quality control
Laser diffraction particle size analyzer - Winner319A - JINAN WINNER PARTICLE INSTRUMENT STOCK COMPANY - optical / laser / for quality control - image - 2
Laser diffraction particle size analyzer - Winner319A - JINAN WINNER PARTICLE INSTRUMENT STOCK COMPANY - optical / laser / for quality control - image - 3
Add to favorites
Compare this product

Characteristics

Technology
laser diffraction, optical, laser
Applications
for quality control, for aerosol sprays, laboratory, spray droplet size, for research
Other characteristics
automatic, benchtop, dry-type, multichannel, wet type

Description

Overview
Winner319A is a bench-top split-type laser particle size analyzer designed for spray and aerosol droplet measurement. It applies the Fraunhofer diffraction principle with a parallel light-path layout and an LD pump laser (λ = 532 nm, >40 mW) with a rated lifetime >25000 hours. The instrument is intended for research institutes, university laboratories, corporate R&D centres and quality testing facilities.

Main Specifications
Model Name: Winner319A
Standards: ISO13320-1:1999, GB/T19077.1-2008, Q/0100JWN001-2013
Principle: Fraunhofer diffraction
Instrument structure: Split-Type (transmit and receive modules)
Data acquisition rate: ≧2 KHz
Sampling mode: Open style
Air purging/protection: Airflow protection device to prevent optical contamination during spray testing
Working temperature: 10–40 °C
Environment humidity: ≤75%
Outer dimensions: Transmit port L369 × W295 × H360 mm; Receive port L858 × W295 × H360 mm
Net weight: 68 kg
Power supply: 220 V, 50/60 Hz

Optics
Light source: LD pump laser, λ = 532 nm, >40 mW, lifetime >25000 hours
Optical bench alignment: Automatic alignment system
Lens protection: Dual-stage gas purge protection
Laser safety: Class 3B

Measurement Size
Measurement range: 1–500 μm
Number of channels: 58 channels
Accuracy error: <1.0% (CRM D50)
Repeatability error: <1.0% (CRM D50)
Inter-instrument reproducibility: <1.0% (CRM D50)
Testing area length: 0.1–10 m adjustable

Software Functions
  • Analysis modes: free distribution, R‑R distribution, log‑normal and category-based statistical models.
  • Statistical comparison: compare multiple runs across batches, pre/post processing or different process times.
  • Data processing: intelligent statistical processing to generate representative results.
  • Custom analysis: define any characteristic particle size between D1 and D100, cumulative percentages for ranges and industry-specific outputs.
  • Output: particle size metrics, interval (differential) and cumulative (integral) distributions with graphs (histogram or curve).
  • Report export: Word, Excel, image (BMP), text (TXT) and PDF formats.
  • One-click operation: automated wet and dry workflows (wet: water intake, bubble removal, dispersion, test, clean, data processing; dry: dust collection, air supply, feeding, test, data processing).
  • Interface languages: Chinese and English; additional languages available on request.
  • GMP: optional.

Advantages
  • Patented optical technologies (parallel optical testing, spectral amplification, auxiliary integration detectors) extend dynamic range and improve measurement accuracy by collecting scattered light across angles.
  • Airflow protection device prevents lens contamination during spray tests.
  • Split-type design with adjustable test area enables non-contact, non-intrusive measurements across varied spray conditions.
  • Stable automatic optical-path alignment simplifies setup and preserves measurement stability.
  • Multiple size-distribution models with flexible conversions between volume and number distributions.

Application
Applicable to fire‑fighting sprays, forestry and pesticide spray evaluation, medical nebulizer droplet testing, aircraft engine spray studies, spray prilling and coating, nozzle research, aerosol particle size testing, and laboratories in enterprises, universities and research institutes.

Technical specifications
  • Model Name: Winner319A
  • Measurement range: 1–500 μm
  • Number of channels: 58
  • Principle: Fraunhofer diffraction
  • Light source: LD pump laser (532 nm, >40 mW), lifetime >25000 hours
  • Optical bench alignment: Automatic alignment
  • Laser safety class: 3B
  • Instrument structure: Split-Type
  • Data acquisition rate: ≧2 KHz
  • Sampling mode: Open style
  • Air purge/protection: Airflow protection device
  • Accuracy error: <1.0% (CRM D50)
  • Repeatability error: <1.0% (CRM D50)
  • Inter-instrument reproducibility: <1.0% (CRM D50)
  • Testing area length: 0.1–10 m (adjustable)
  • Working temperature: 10–40 °C
  • Environment humidity: ≤75%
  • Outer dimensions: Transmit port L369 × W295 × H360 mm; Receive port L858 × W295 × H360 mm
  • Net weight: 68 kg
  • Power supply: 220 V, 50/60 Hz
  • Software outputs: interval and cumulative distributions, graphs, customizable D1–D100 metrics
  • Report export formats: Word, Excel, BMP, TXT, PDF
  • One-click operation: wet and dry automated workflows
  • Interface languages: Chinese and English (others on request)

VIDEO

Catalogs

Winner319A
Winner319A
12 Pages
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.