Laser diffraction particle size analyzer Winner3003
laser light scatteringlaserfor quality control

Laser diffraction particle size analyzer - Winner3003 - JINAN WINNER PARTICLE INSTRUMENT STOCK COMPANY - laser light scattering / laser / for quality control
Laser diffraction particle size analyzer - Winner3003 - JINAN WINNER PARTICLE INSTRUMENT STOCK COMPANY - laser light scattering / laser / for quality control
Laser diffraction particle size analyzer - Winner3003 - JINAN WINNER PARTICLE INSTRUMENT STOCK COMPANY - laser light scattering / laser / for quality control - image - 2
Laser diffraction particle size analyzer - Winner3003 - JINAN WINNER PARTICLE INSTRUMENT STOCK COMPANY - laser light scattering / laser / for quality control - image - 3
Add to favorites
Compare this product

Characteristics

Technology
laser diffraction, laser light scattering, laser
Applications
laboratory, for research, for quality control, for the pharmaceutical industry
Other characteristics
automatic, dry-type, high-performance, for powders, benchtop

Description

Product Overview
Winner3003 is a dry dispersion laser particle size analyzer designed for accurate and repeatable measurement of powders using Mie scattering theory. It integrates a converging Fourier optical path, a high-performance 639 nm laser and a high-sensitivity photodetector ring. The instrument uses air turbulent dispersion combined with a precision feeding device, a patented powder spray pump and an oil-free silent gas source to ensure complete dispersion of dry samples. It is particularly suited to powders that react or change shape in liquid media.

Key Features
  • Dry dispersion measurement based on Mie scattering.
  • Converging Fourier (folded) optical path with high-performance laser λ = 639 nm, P > 2 mW and high-sensitivity detector ring.
  • Turbulent dry dispersion with automatic sample introduction and SOP one-click operation.
  • Patented powder spray pump and oil-free silent gas source for consistent dispersion.
  • Automatic three-dimensional optical bench alignment and Class 1 laser safety.


Applications
  • Cement and ceramics production quality control.
  • Pharmaceutical powders, pigments, dyes and fillers.
  • Chemicals, catalysts and functional powders.
  • Coal dust, additives, pesticides and energetic materials (as applicable to facility safety).
  • Metal and non-metal powders, graphite, calcium carbonate, kaolin and other mineral powders.
  • Materials sensitive to liquid media (e.g., magnetic powders, botanicals).


Advantages
  • Automated SOP workflow: automated dust removal, air supply, feeding, measurement and data processing to reduce operator variability.
  • Robust dry dispersing system: turbulent patented dispersion and wear-resistant ceramic core for stable, long-life operation.
  • Automatic optical alignment with precise hybrid stepper motor for micron-level positioning.
  • Advanced optical design collecting scattering light across the measurement range for consistent accuracy.
  • Flexible fitting models allowing free-distribution fitting and multiple statistical analyses.


Main Specifications
  • Model: Winner3003
  • Principle: Mie scattering
  • Measurement range: 0.1–300 μm
  • Number of channels: 40
  • Accuracy error: ≤1.0% (CRM D50)
  • Repeatability error: ≤1.0% (CRM D50)
  • Dispersion method: Turbulent dry dispersion, automatic sample introduction
  • Test speed: fastest 10 seconds
  • Sampling frequency: up to 10 kHz
  • Light source: Laser λ = 639 nm, P > 2 mW
  • Optical path: Reverse Fourier (folded)
  • Optical bench alignment: Automatic (3D)
  • Laser safety class: 1
  • Dimensions: Main unit 765×450×325 mm; Dry module 260×245×295 mm
  • Net weight: Main unit 26 kg; Dry module 7 kg
  • Operation mode: SOP fully automated, one-click testing


Software & Output
  • Analysis models: free distribution, R-R, log-normal and other statistical fits.
  • Batch-to-batch and process comparison tools for QC and cost control.
  • Intelligent data processing to produce representative particle size results.
  • Custom outputs: any D1–D100 characteristic sizes, cumulative and interval distributions.
  • Outputs: particle size metrics, differential and cumulative distributions as data and graphs (histograms/curves).
  • Report export: Word, Excel, BMP, TXT, PDF.
  • One-click automation of dust collection, air supply, feeding, measurement and processing.
  • Interface languages: English and Chinese (additional languages configurable).
  • GMP compliance: optional.


Technical Specifications
  • Model: Winner3003
  • Measurement range: 0.1–300 μm
  • Principle: Mie scattering
  • Light source: Laser λ = 639 nm, P > 2 mW
  • Channels: 40
  • Accuracy error: ≤1.0% (CRM D50)
  • Repeatability: ≤1.0% (CRM D50)
  • Sampling frequency: up to 10 kHz
  • Test speed: ≥10 s (fastest)
  • Dispersion: Turbulent dry dispersion, automatic feed
  • Optical path: Reverse Fourier (folded)
  • Optical bench: Automatic alignment
  • Laser safety class: 1
  • Dimensions: Main 765×450×325 mm; Dry module 260×245×295 mm
  • Net weight: Main 26 kg; Dry module 7 kg
  • Output formats: Word, Excel, BMP, TXT, PDF

VIDEO

Catalogs

Winner3003
Winner3003
10 Pages
Winner2018
Winner2018
10 Pages
Winner3006
Winner3006
11 Pages
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.