Product overview:The CellaCombustion PA 17 is a single‑wavelength pyrometer designed to measure the temperature of hot, carbonaceous CO2 combustion gases in combustion chambers, power plants and waste incineration facilities. Measurement takes place in a CO2‑specific spectral band; measuring depth depends on CO2 concentration. A focusable lens together with through‑the‑lens sighting or an integrated video camera ensures precise alignment to the measuring point. The device features a 75:1 optical distance ratio, measuring range 400–2000 °C and stainless steel housing with IP65 protection.
Applications:- Temperature monitoring in waste incineration plants
- Combustion control in power plants and industrial boilers
- Process monitoring in furnaces and burners
- Pyrolysis and thermal treatment processes
- Research and emission measurement applications
Key features:- Measuring range 400 to 2,000 °C
- Focusable lenses for exact adjustment of measuring distance
- Broadband anti‑reflective precision optics
- 4‑digit red LED display, readable from distance
- Test current output for diagnostic checks
- Standard I/O: digital input/output, two analogue outputs, USB and RS‑485 interfaces
Optical / mechanical options and versions:- Version: CellaCombustion PA 17 AF 1
- Measuring principle: one‑colour (single‑wavelength)
- Shape of measuring field: round
- Distance ratio: 75 : 1
- Objective: PZ 15.03 (standard lens)
- Focus distance: 0.8 m – ∞
- Sighting options: through‑the‑lens sighting, video camera, laser pilot light (depending on configuration)
Scope of delivery / accessories (standard):- Pyrometer CellaCombustion PA 17
- Connection cable VK 02/A (5 m)
- Video cable VK 02/F (5 m) for camera models
- USB cable VK 11/D (1.8 m)
- Software CellaView
- Short manual
Notes:Measuring depth depends on CO2 concentration. Focusable lens and sighting/video camera enable precise alignment to the measuring point.
Technical specifications:- Measuring range: 400 - 2000 °C
- Sensor: Thermopile
- Spectral range: CO2 range
- Response time t98: ≤ 100 ms
- Measurement uncertainty: 0.75 % of temperature reading [°C] + 1 K
- Repeatability: 2 K
- Temperature coefficient: 0.04 %/K
- Resolution current output: 0.2 K + 0.03 % of selected range
- Resolution interface: 0.1 K
- Resolution display: 1 K
- Standard lens: PZ 15.03 (focusing 0.8 m - ∞)
- Optical distance ratio: 75 : 1
- Analog output: 0(4) - 20 mA linear, switchable, scalable
- Load resistance for current output: ≤ 500 Ω
- Analog input: 0 - 10 V
- Switching outputs: 2 × Open Collector 24 V DC, ≤ 30 mA
- Switching inputs: 2 × to 24 V
- Interfaces: USB, RS 485
- Power supply: 24 V DC +10 % / -20 %
- Current consumption: ≤ 175 mA (for 24 V DC)
- Camera (for camera models): Video output Composite PAL, 1 Vpp, 75 Ω
- Display / indicators: 4‑digit red LED display (8 mm), 2 × LED status display, 3 control buttons
- Connection: M12 thread 8‑pin connection
- Operating ambient temperature: 0 - 65 °C
- Storage temperature: -20 - +80 °C
- Permissible humidity: 95 % r.H. max. (non‑condensing)
- Dimensions: Ø 65 mm × 220 mm (max. 277 mm)
- Housing: Stainless steel V2A (1.4305)
- Protection class: IP 65 (according to DIN 40050)
- Weight: approx. 0.9 kg
- Functions: overtemperature signal (if internal temperature exceeds 80 °C the analogue output shows a value > 20.5 mA), service function (simulation of measured value or current signal), ATD (Automatic Temperature Detection) for discontinuous processes
- Adjustable parameters: measuring range, measured variable and analogue I/O scaling, smoothing filter, memory operation mode and hold time, emissivity, transmittance, compensation of reflected ambient radiation, alarm limits and modes, ATD parameters (optional), linearization function, LED status indications, simulation of current/temperature, temperature unit °C/°F; camera models additionally: TBC function, white balance