Pyrometer with LED display CellaCombustion PA 17
°C°F75:1

Pyrometer with LED display - CellaCombustion PA 17 - Keller Pyrometer Systems - °C / °F / 75:1
Pyrometer with LED display - CellaCombustion PA 17 - Keller Pyrometer Systems - °C / °F / 75:1
Pyrometer with LED display - CellaCombustion PA 17 - Keller Pyrometer Systems - °C / °F / 75:1 - image - 2
Add to favorites
Compare this product

Characteristics

Display
with LED display
Units of measurement
°C, °F
Optical resolution
75:1
Aim
with laser pointer
Communication
USB, analog output, digital output
Protection level
IP65
Applications
for flue gas
Other characteristics
stainless steel, precision, optical
Temperature

Min.: 400 °C
(752 °F)

Max.: 2,000 °C
(3,632 °F)

Response time

100 ms

Description

Product overview:
The CellaCombustion PA 17 is a single‑wavelength pyrometer designed to measure the temperature of hot, carbonaceous CO2 combustion gases in combustion chambers, power plants and waste incineration facilities. Measurement takes place in a CO2‑specific spectral band; measuring depth depends on CO2 concentration. A focusable lens together with through‑the‑lens sighting or an integrated video camera ensures precise alignment to the measuring point. The device features a 75:1 optical distance ratio, measuring range 400–2000 °C and stainless steel housing with IP65 protection.

Applications:
  • Temperature monitoring in waste incineration plants
  • Combustion control in power plants and industrial boilers
  • Process monitoring in furnaces and burners
  • Pyrolysis and thermal treatment processes
  • Research and emission measurement applications


Key features:
  • Measuring range 400 to 2,000 °C
  • Focusable lenses for exact adjustment of measuring distance
  • Broadband anti‑reflective precision optics
  • 4‑digit red LED display, readable from distance
  • Test current output for diagnostic checks
  • Standard I/O: digital input/output, two analogue outputs, USB and RS‑485 interfaces


Optical / mechanical options and versions:
  • Version: CellaCombustion PA 17 AF 1
  • Measuring principle: one‑colour (single‑wavelength)
  • Shape of measuring field: round
  • Distance ratio: 75 : 1
  • Objective: PZ 15.03 (standard lens)
  • Focus distance: 0.8 m – ∞
  • Sighting options: through‑the‑lens sighting, video camera, laser pilot light (depending on configuration)


Scope of delivery / accessories (standard):
  • Pyrometer CellaCombustion PA 17
  • Connection cable VK 02/A (5 m)
  • Video cable VK 02/F (5 m) for camera models
  • USB cable VK 11/D (1.8 m)
  • Software CellaView
  • Short manual


Notes:
Measuring depth depends on CO2 concentration. Focusable lens and sighting/video camera enable precise alignment to the measuring point.

Technical specifications:
  • Measuring range: 400 - 2000 °C
  • Sensor: Thermopile
  • Spectral range: CO2 range
  • Response time t98: ≤ 100 ms
  • Measurement uncertainty: 0.75 % of temperature reading [°C] + 1 K
  • Repeatability: 2 K
  • Temperature coefficient: 0.04 %/K
  • Resolution current output: 0.2 K + 0.03 % of selected range
  • Resolution interface: 0.1 K
  • Resolution display: 1 K
  • Standard lens: PZ 15.03 (focusing 0.8 m - ∞)
  • Optical distance ratio: 75 : 1
  • Analog output: 0(4) - 20 mA linear, switchable, scalable
  • Load resistance for current output: ≤ 500 Ω
  • Analog input: 0 - 10 V
  • Switching outputs: 2 × Open Collector 24 V DC, ≤ 30 mA
  • Switching inputs: 2 × to 24 V
  • Interfaces: USB, RS 485
  • Power supply: 24 V DC +10 % / -20 %
  • Current consumption: ≤ 175 mA (for 24 V DC)
  • Camera (for camera models): Video output Composite PAL, 1 Vpp, 75 Ω
  • Display / indicators: 4‑digit red LED display (8 mm), 2 × LED status display, 3 control buttons
  • Connection: M12 thread 8‑pin connection
  • Operating ambient temperature: 0 - 65 °C
  • Storage temperature: -20 - +80 °C
  • Permissible humidity: 95 % r.H. max. (non‑condensing)
  • Dimensions: Ø 65 mm × 220 mm (max. 277 mm)
  • Housing: Stainless steel V2A (1.4305)
  • Protection class: IP 65 (according to DIN 40050)
  • Weight: approx. 0.9 kg
  • Functions: overtemperature signal (if internal temperature exceeds 80 °C the analogue output shows a value > 20.5 mA), service function (simulation of measured value or current signal), ATD (Automatic Temperature Detection) for discontinuous processes
  • Adjustable parameters: measuring range, measured variable and analogue I/O scaling, smoothing filter, memory operation mode and hold time, emissivity, transmittance, compensation of reflected ambient radiation, alarm limits and modes, ATD parameters (optional), linearization function, LED status indications, simulation of current/temperature, temperature unit °C/°F; camera models additionally: TBC function, white balance

Exhibitions

Meet this supplier at the following exhibition(s):

Shenzhen International Semiconductor & IC Exhibition
Shenzhen International Semiconductor & IC Exhibition

9-11 Sep 2026 Shenzhen (China)

Inter Foundry 2026
Inter Foundry 2026

10-12 Sep 2026 Coimbatore (India)

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.