Pressure measuring system CellaTemp PA 40-K029
temperatureflowlaser

Pressure measuring system - CellaTemp PA 40-K029 - Keller Pyrometer Systems - temperature / flow / laser
Pressure measuring system - CellaTemp PA 40-K029 - Keller Pyrometer Systems - temperature / flow / laser
Pressure measuring system - CellaTemp PA 40-K029 - Keller Pyrometer Systems - temperature / flow / laser - image - 2
Pressure measuring system - CellaTemp PA 40-K029 - Keller Pyrometer Systems - temperature / flow / laser - image - 3
Add to favorites
Compare this product

Characteristics

Measured physical value
temperature, pressure, flow
Technology
optical, camera-based, laser
Operating mode
automatic
Measured material
parts
Configuration
linear

Description

Measuring system consisting of:
  • Pyrometer CellaTemp PA 40 AF 1
  • Mounting SK 824


Special features:
  • Two-colour pyrometer with focusable optics in a stainless steel housing
  • Broadband anti-reflective precision lens
  • 2 analogue outputs, 2 switching outputs, USB and RS 485 interface
  • Sighting aid: through-the-lens sighting
  • Mounting fitting with cooling fitting and air purge for industrial use
  • Pneumatic and mechanical ball valve
  • Switch cabinet with control system for the pneumatic ball valve
  • Flow monitor and pressure controller and connection for air and mains voltage


Scope of delivery:
  • Pyrometer CellaTemp PA
  • Connection cable VK 02/A (5 m)
  • Video cable VK 02/F (5 m) for model with built-in camera
  • USB cable VK 11/D (1.8 m)
  • Software CellaView
  • Manual (short)


Measurement / optical data (summary):
Measuring range: 500 - 3000 °C (in several segments)
Spectral range: 0.95 / 1.05 µm
Measuring principle: two-colour
Sensor: Double photo diode
Distance ratio: 80 : 1
Shape of the measuring field: round
Objective (standard): PZ 20.01 (focusing 0.4 m - ∞)
Available lenses (summary): close-up lens PZ 20.03 (0.2 m - 0.4 m), wide-angle PZ 20.05 (0.2 m - ∞), telephoto PZ 20.06 (1.2 m - ∞) and PA 20.06 (0.6 m - ∞); for highest ranges macro lens PA 40.01 (0.086 m - 0.115 m), lens F50 PZ 20.08 (for 500 - 1400 °C) etc.
Focus distance: 0.4 m - ∞ (standard objective)

Response times and accuracy:
Response time t98 by measuring range:
- 500 - 1400 °C: ≤ 10 ms (T > 650 °C)
- 650 - 1700 °C: ≤ 20 ms (T > 650 °C) and ≤ 10 ms (T > 750 °C)
- 750 - 2400 °C: ≤ 10 ms (T > 950 °C)
- 850 - 3000 °C: ≤ 10 ms (T > 1050 °C)
Measurement uncertainty: 1 % of temperature reading [°C]
Repeatability: 2 K
Temperature coefficient: 0.05 %/K
Resolution current output: 0.2 K + 0.03 % of selected range
Resolution interface: 0.1 K
Resolution display: 1 K

Electrical / interface data:
Analog output: 0(4) - 20 mA linear, switchable, scalable
Resistance: ≤ 500 Ω
Analog input: 0 - 10 V
Switching output: 2 x Open Collector 24 V DC, ≤ 30 mA
Switching input: 2 x to 24 V
Interfaces: USB and RS 485
Power supply: 24 V DC +10 % / -20 %
Current consumption: ≤ 175 mA for 24 V DC

Camera / sighting / display features:
Sighting options: through-the-lens sighting, laser pilot light, camera (model variants)
Video output (camera model): Composite PAL, 1 Vpp, 75 Ω
Display: 4-digit red LED display, digit-height 8 mm
Status display: 2 x LED
Control elements: 3 buttons

General parameters:
Connection: M12 thread 8-pin connection
Ambient temperature (operating): 0 - 65 °C
Storage temperature: -20 - +80 °C
Permissible humidity: 95 % r.H. max. (non-condensing)
Dimension: Ø 65 mm x 220 mm (max. 277 mm)
Housing: Stainless steel V2A (1.4305)
Protection class: IP 65 (according to DIN 40050)
Weight: approx. 0.9 kg

Functions / adjustable parameters (overview):
Overtemperature signal (if internal temperature > 80 °C analogue output shows > 20.5 mA); simulation of measured value or current signal; ATD (Automatic Temperature Detection) function; smoothing filter, emissivity/transmittance settings, compensation of reflected ambient radiation, alarm contact limits and modes, linearization, measurement channels (two-colour, single-colour 1 and 2), contamination monitoring threshold, TBC and white balance for camera models.

Version / Item information:
Version: CellaTemp PA 40-K029
Measuring range example (typical configuration): 650 - 1700 °C
Item No.: 1112417

Technical specifications:
  • Product: Measuring system PA 40-K029 (CellaTemp PA 40 AF 1 + Mounting SK 824)
  • Measuring principle: Two-colour (dual-wavelength)
  • Measuring range: 500 - 3000 °C (segmented)
  • Spectral range: 0.95 / 1.05 µm
  • Distance ratio: 80 : 1
  • Standard objective: PZ 20.01 (focus 0.4 m - ∞)
  • Analogue outputs: 0(4) - 20 mA (2 channels)
  • Switching outputs: 2 x Open Collector 24 V DC
  • Interfaces: USB, RS 485
  • Power supply: 24 V DC (+10 % / -20 %)
  • Housing: Stainless steel V2A (1.4305), Protection class IP65
  • Dimensions: Ø 65 mm x 220 mm (max. 277 mm); Weight ≈ 0.9 kg
  • Included software: CellaView

Catalogs

No catalogs are available for this product.

See all of Keller Pyrometer Systems‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

Shenzhen International Semiconductor & IC Exhibition
Shenzhen International Semiconductor & IC Exhibition

9-11 Sep 2026 Shenzhen (China)

Inter Foundry 2026
Inter Foundry 2026

10-12 Sep 2026 Coimbatore (India)

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.