Overview- Fully welded cold-rolled steel body with a primed and powder-coated surface.
- Reinforced pressed-corner door helps maintain rigidity and consistent gasket compression.
- Continuous PU foamed gasket supports the IP66 metal enclosure protection level when cable entries and installed devices are correctly sealed.
- Galvanized mounting plate and 130° zinc-alloy bearing hinges support easier component assembly and maintenance.
- Removable gland plates and prepared rear mounting points simplify cable entry and wall installation.
Technical DataParameter | Specification
Enclosure Material | Cold-rolled steel sheet
Body Construction | Fully welded and precision-ground steel body
Door Construction | Reinforced pressed-corner steel door
Surface Treatment | Etch primer with exterior powder coating
Protection Rating | IP66 / NEMA 4X
Standard Color | RAL 7032 or RAL 7035 textured finish
Body Thickness | 1.5 mm
Door Thickness | 1.5–2.0 mm, depending on model
Mounting Plate | 2.0–3.0 mm galvanized steel, depending on model
Door Opening | Approximately 130°
Cable Entry | Removable bottom gland plate or plates
Wall Installation | Direct wall mounting or optional mounting brackets
Grounding | Connection points on the body, door and mounting plate
Standard Supply | Body, door, gasket, mounting plate, grounding set, lock and model-specific gland plate
Specification Data (order table)No. | Order number | Width | Height | Depth | Box Body Thickness | Door Thickness | Mounting Plate Thickness | Number of door | Number of Cam locks | Number of Gland Plate
1 | SAE203012005 | 200 | 300 | 120 | 1.5 | 1.5 | 2.0 | 1 | 1 | 1
2 | SAE203015005 | 200 | 300 | 150 | 1.5 | 1.5 | 2.0 | 1 | 1 | 1
3 | SAE303015005 | 300 | 300 | 150 | 1.5 | 1.5 | 2 | 1 | 1 | 1
4 | SAE303021005 | 300 | 300 | 210 | 1.5 | 1.5 | 2.0 | 1 | 1 | 1
5 | SAE304021005 | 300 | 400 | 210 | 1.5 | 1.5 | 2 | 1 | 1 | 1
6 | SAE383015005 | 380 | 300 | 150 | 1.5 | 1.5 | 2 | 1 | 1 | 1
7 | SAE383021005 | 380 | 300 | 210 | 1.5 | 1.5 | 2.0 | 1 | 1 | 1
8 | SAE383821005 | 380 | 380 | 210 | 1.5 | 1.5 | 2.0 | 1 | 1 | 1
9 | SAE386021005 | 380 | 600 | 210 | 1.5 | 1.5 | 2.5 | 1 | 2 | 1
10 | SAE386035005 | 380 | 600 | 350 | 1.5 | 1.5 | 2.5 | 1 | 2 | 1
11 | SAE405021005 | 400 | 500 | 210 | 1.5 | 1.5 | 2.0 | 1 | 2 | 1
12 | SAE408030005 | 400 | 800 | 300 | 1.5 | 2 | 3 | 1 | 2 | 1
13 | SAE505021005 | 500 | 500 | 210 | 1.5 | 2 | 2.5 | 1 | 2 | 1
14 | SAE505030005 | 500 | 500 | 300 | 1.5 | 2 | 2.5 | 1 | 2 | 1
15 | SAE507025005 | 500 | 700 | 250 | 1.5 | 2 | 2.5 | 1 | 2 | 1
16 | SAE603821005 | 600 | 380 | 210 | 1.5 | 1.5 | 2.5 | 1 | 1 | 1
17 | SAE603835005 | 600 | 380 | 350 | 1.5 | 1.5 | 2.5 | 1 | 1 | 1
18 | SAE606021005 | 600 | 600 | 210 | 1.5 | 2 | 2.5 | 1 | 2 | 1
19 | SAE606025005 | 600 | 600 | 250 | 1.5 | 2 | 2.5 | 1 | 2 | 1
20 | SAE606035005 | 600 | 600 | 350 | 1.5 | 2 | 2.5 | 1 | 2 | 1
21 | SAE607621005 | 600 | 760 | 210 | 1.5 | 2 | 3.0 | 1 | 2 | 1
22 | SAE607635005 | 600 | 760 | 350 | 1.5 | 2 | 3 | 1 | 2 | 1
23 | SAE608025005 | 600 | 800 | 250 | 1.5 | 2 | 3 | 1 | 2 | 1
24 | SAE601025005 | 600 | 1000 | 250 | 1.5 | 2 | 3 | 1 | 2 | 1
25 | SAE601230005 | 600 | 1200 | 300 | 1.5 | 2 | 3 | 1 | 3-point lock | 1
26 | SAE767621005 | 760 | 760 | 210 | 1.5 | 2 | 3 | 1 | 2 | 1
27 | SAE767630005 | 760 | 760 | 300 | 1.5 | 2 | 3.0 | 1 | 2 | 1
28 | SAE806030005 | 800 | 600 | 300 | 1.5 | 2 | 2.5 | 1 | 2 | 1
29 | SAE801030005 | 800 | 1000 | 300 | 1.5 | 2 | 3 | 1 | 2 | 1
30 | SAE801230005 | 800 | 1200 | 300 | 1.5 | 2 | 3 | 1 | 3-point lock | 1
31 | SAE107621005 | 1000 | 760 | 210 | 1.5 | 2 | 3 | 2 | 2 | 2
32 | SAE107630005 | 1000 | 760 | 300 | 1.5 | 2 | 3 | 2 | 2 | 2
33 | SAE101030005 | 1000 | 1000 | 300 | 1.5 | 2 | 3 | 2 | 2 | 2
34 | SAE101230005 | 1000 | 1200 | 300 | 1.5 | 2 | 3 | 2 | 3-point lock | 2
35 | SAE101430005 | 1000 | 1400 | 300 | 1.5 | 2 | 3 | 2 | 3-point lock | 2
Design & Configuration The SAE steel electrical enclosure combines a reinforced pressed-corner door, multi-folded body frame, 130° bearing hinges, galvanized mounting plate and removable gland plates in a space-efficient wall mount enclosure design. Standard supply includes the enclosure body and door, PU foamed gasket, galvanized mounting plate, grounding components, standardized lock and the gland plate quantity listed for the selected order number. Project-specific processing can include specified enclosure dimensions, door cutouts for meters, switches, push buttons and HMI panels, pre-punched gland plates and mounting plate drilling.
Installation Guide- Prepare the Mounting Plate Remove the galvanized mounting plate and mark the positions of DIN rails, wiring ducts, terminals and other electrical components. Component installation and preliminary wiring can be completed outside the enclosure.
- Prepare the Cable Entry Remove the model-specific bottom gland plate and machine the required cable-entry holes according to the cable quantity and gland size. Install suitable cable glands and correctly position the gland plate gasket.
- Mount the Enclosure Use the prepared rear mounting points or compatible mounting brackets and fasteners according to the wall material, enclosure size and final equipment weight. Confirm that the enclosure is level and securely supported.
- Complete Grounding and Sealing Reinstall the mounting plate, complete the internal wiring and connect the grounding points on the door, enclosure body and mounting plate. Check the hinges, lock, gasket compression and gland plate before commissioning.
Applications These compact steel electrical boxes are suitable for projects requiring wall-mounted protection without the footprint of a larger floor-standing cabinet.
Caractéristiques / spécifications techniques- Material: cold-rolled steel sheet, fully welded construction.
- Protection rating: IP66 (also indicated NEMA 4X).
- Surface finish: etch primer with exterior powder coating; standard textured RAL 7032 or RAL 7035.
- Gasket: continuous PU foamed gasket for environmental sealing.
- Mounting plate: galvanized steel, removable (2.0–3.0 mm depending on model).
- Hinges: 130° zinc-alloy bearing hinges.
- Door: reinforced pressed-corner door; door thickness 1.5–2.0 mm depending on model.
- Cable entry: removable gland plates (quantity by model) for flexible entry options.
- Wall installation: prepared rear mounting points or optional mounting brackets.
- Customisation: door cutouts, gland plate openings and mounting plate drilling available to project drawings.