Key information- Product: Outdoor compact transformer substation
- Series: YB
- Rated HV: 33 kV (variant)
- Typical transformer range: 50–1250 kVA
- Enclosure: steel (stainless steel option)
- Protection: IP65 (compartment-specific ratings may apply)
Product descriptionThe YB series prefabricated substation configured for 33 kV outdoor applications integrates transformer, HV and LV switchgear, metering, compensation and protection functions in a compact, factory-assembled unit. It is designed for ring network, dual-source or terminal supply schemes and for deployment in industrial sites, residential areas, commercial centres and tall buildings. The unit is available with steel or stainless-steel enclosure and modular internal compartments for easy commissioning and maintenance.
Structural features- Box layout divided into front operational compartments (HV/LV) and rear tank/cooling section
- HV compartment can accommodate multi-position load switches, plug-in fuses and measurement interfaces
- Transformer tank, windings and radiator located in rear section with oil monitoring and drain provisions
- Modular LV compartment for controllers, distribution breakers, compensation equipment and energy meters
Normal use environmental conditions- Altitude: up to 1000 m
- Wind pressure: ≤ 70 Pa (≈35 m/s)
- Humidity: daily average ≤ 90%, monthly average ≤ 90%
- Ambient temperature: -25°C to +40°C
- Anti-vibration: horizontal accel. 0.4 m/s²; vertical 0.15 m/s²
- Seismic intensity: up to 8 degrees
- Installation: free of heavy corrosive/flammable gases and severe vibration
Performance characteristics- Space-efficient design: reduced footprint compared with conventional box substations
- Fully sealed and insulated configuration for safe outdoor operation
- Flexible for ring network or terminal schemes; simplified conversion between modes
- Low losses; transformer options meet industry loss targets
- Cable connector rated for 200 A; can act as emergency load switching point
- Dual fuse protection (plug-in) for reliable protection and reduced operating cost
- O/Y connection and three-phase five-column structure for stable voltage, low noise and good lightning performance
Main technical parameters (typical)- HV rated voltage: 33 kV (variant) / typical reference 12 kV in other configurations
- LV output: 10/0.4 kV or 0.4 kV
- Rated current example (HV): 630 A
- Rated frequency: 50 Hz
- Transformer capacity: 50–1250 kVA (depending on configuration)
- Power-frequency withstand (1 min): values per configuration (e.g. 42/48 kV ground/interphase)
- Lightning impulse withstand: up to 75 kV (depending on equipment)
- Enclosure options: fully enclosed steel or stainless steel; compartments may be IP54/IP65 as specified
- Typical dimensions: 1825×1400×2020 mm up to 3945×1560×2020 mm (varies by configuration)
Options & surface treatment- Standard steel enclosure with anticorrosion pretreatment and electrostatic powder coating
- Stainless-steel enclosure with honeycomb double-layer option for improved corrosion resistance and thermal behavior
- Color finish and surface texture per customer requirements
Ordering informationProvide the following when ordering:
- Box style (European or American)
- Transformer model and rated capacity
- Primary wiring diagrams for HV and LV
- HV supply mode (ring network, terminal, etc.), HV load switch model and measurement method
- LV main switch model, metering method, outlet switch types and number of circuits
- LV reactive compensation method and capacity
- Box material and finish (steel, stainless, aluminium alloy + color steel, etc.)
- Any special requirements to be agreed with manufacturer