video corpo
  • Products
  • Catalogs
  • News & Trends
  • Exhibitions

Power distribution substation YB
for medium-voltage transformerscompactprefabricated

Power distribution substation - YB - SAIP ELECTRIC GROUP CO.,LTD - for medium-voltage transformers / compact / prefabricated
Power distribution substation - YB - SAIP ELECTRIC GROUP CO.,LTD - for medium-voltage transformers / compact / prefabricated
Add to favorites
Compare this product

Characteristics

Fonction
power distribution, for medium-voltage transformers
Options and accessories
prefabricated, compact, outdoor, modular
Rated voltage

Min.: 7.2 kV

Max.: 12 kV

Current

630 A

Description

Key information
  • Product: Outdoor compact transformer substation
  • Series: YB
  • Rated HV: 33 kV (variant)
  • Typical transformer range: 50–1250 kVA
  • Enclosure: steel (stainless steel option)
  • Protection: IP65 (compartment-specific ratings may apply)


Product description
The YB series prefabricated substation configured for 33 kV outdoor applications integrates transformer, HV and LV switchgear, metering, compensation and protection functions in a compact, factory-assembled unit. It is designed for ring network, dual-source or terminal supply schemes and for deployment in industrial sites, residential areas, commercial centres and tall buildings. The unit is available with steel or stainless-steel enclosure and modular internal compartments for easy commissioning and maintenance.

Structural features
  • Box layout divided into front operational compartments (HV/LV) and rear tank/cooling section
  • HV compartment can accommodate multi-position load switches, plug-in fuses and measurement interfaces
  • Transformer tank, windings and radiator located in rear section with oil monitoring and drain provisions
  • Modular LV compartment for controllers, distribution breakers, compensation equipment and energy meters


Normal use environmental conditions
  • Altitude: up to 1000 m
  • Wind pressure: ≤ 70 Pa (≈35 m/s)
  • Humidity: daily average ≤ 90%, monthly average ≤ 90%
  • Ambient temperature: -25°C to +40°C
  • Anti-vibration: horizontal accel. 0.4 m/s²; vertical 0.15 m/s²
  • Seismic intensity: up to 8 degrees
  • Installation: free of heavy corrosive/flammable gases and severe vibration


Performance characteristics
  • Space-efficient design: reduced footprint compared with conventional box substations
  • Fully sealed and insulated configuration for safe outdoor operation
  • Flexible for ring network or terminal schemes; simplified conversion between modes
  • Low losses; transformer options meet industry loss targets
  • Cable connector rated for 200 A; can act as emergency load switching point
  • Dual fuse protection (plug-in) for reliable protection and reduced operating cost
  • O/Y connection and three-phase five-column structure for stable voltage, low noise and good lightning performance


Main technical parameters (typical)
  • HV rated voltage: 33 kV (variant) / typical reference 12 kV in other configurations
  • LV output: 10/0.4 kV or 0.4 kV
  • Rated current example (HV): 630 A
  • Rated frequency: 50 Hz
  • Transformer capacity: 50–1250 kVA (depending on configuration)
  • Power-frequency withstand (1 min): values per configuration (e.g. 42/48 kV ground/interphase)
  • Lightning impulse withstand: up to 75 kV (depending on equipment)
  • Enclosure options: fully enclosed steel or stainless steel; compartments may be IP54/IP65 as specified
  • Typical dimensions: 1825×1400×2020 mm up to 3945×1560×2020 mm (varies by configuration)


Options & surface treatment
  • Standard steel enclosure with anticorrosion pretreatment and electrostatic powder coating
  • Stainless-steel enclosure with honeycomb double-layer option for improved corrosion resistance and thermal behavior
  • Color finish and surface texture per customer requirements


Ordering information
Provide the following when ordering:
  • Box style (European or American)
  • Transformer model and rated capacity
  • Primary wiring diagrams for HV and LV
  • HV supply mode (ring network, terminal, etc.), HV load switch model and measurement method
  • LV main switch model, metering method, outlet switch types and number of circuits
  • LV reactive compensation method and capacity
  • Box material and finish (steel, stainless, aluminium alloy + color steel, etc.)
  • Any special requirements to be agreed with manufacturer
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.