Overview- Empty steel wall-mount enclosure series SPT for control panel assembly and electrical equipment protection.
- Continuous PU foamed door gasket and IK10 impact resistance; designed for indoor and sealed outdoor installations (IP66).
- Removable galvanized mounting plate for component installation and pre-wiring outside the enclosure.
- Removable bottom gland plate for cable entry and multiple protection grooves at the door opening for structural reinforcement.
- Double-tooth cylinder lock with keys and standard fixing hardware.
Technical DataEnclosure material: Cold-rolled steel body and door
Mounting plate: Galvanized steel sheet (removable)
Surface treatment: Thermosetting powder coating, textured finish (standard RAL 7035)
Protection rating: IP66
Impact resistance: IK10
Reference temperature range: -40°C to +80°C
Door seal: Continuous PU foamed gasket
Door configuration: Single door, left-side hinges (standard)
Locking system: Double-tooth cylinder lock
Cable entry: Removable bottom gland plate with sealing gasket
Optional accessories: Grounding wire; painted steel or stainless-steel mounting brackets
Available Sizes / Order NumbersSPT202010 — H 200 mm × W 200 mm × D 100 mm, Wall 1.2 mm
SPT252015 — H 250 mm × W 200 mm × D 150 mm, Wall 1.2 mm
SPT302015 — H 300 mm × W 200 mm × D 150 mm, Wall 1.2 mm
SPT302520 — H 300 mm × W 250 mm × D 200 mm, Wall 1.2 mm
SPT403020 — H 400 mm × W 300 mm × D 200 mm, Wall 1.2 mm
SPT503020 — H 500 mm × W 300 mm × D 200 mm, Wall 1.2 mm
SPT503030 — H 500 mm × W 300 mm × D 300 mm, Wall 1.2 mm
SPT504020 — H 500 mm × W 400 mm × D 200 mm, Wall 1.2 mm
SPT505025 — H 500 mm × W 500 mm × D 250 mm, Wall 1.2 mm
SPT604020 — H 600 mm × W 400 mm × D 200 mm, Wall 1.2 mm (door with stiffeners)
SPT604025 — H 600 mm × W 400 mm × D 250 mm, Wall 1.2 mm (door with stiffeners)
SPT605020 — H 600 mm × W 500 mm × D 200 mm, Wall 1.2 mm (door with stiffeners)
SPT605025 — H 600 mm × W 500 mm × D 250 mm, Wall 1.2 mm (door with stiffeners)
SPT705020 — H 700 mm × W 500 mm × D 200 mm, Wall 1.2 mm (door with stiffeners)
SPT705025 — H 700 mm × W 500 mm × D 250 mm, Wall 1.2 mm (door with stiffeners)
SPT806025 — H 800 mm × W 600 mm × D 250 mm, Wall 1.5 mm (door with stiffeners)
SPT806030 — H 800 mm × W 600 mm × D 300 mm, Wall 1.5 mm (door with stiffeners)
SPT1006030 — H 1000 mm × W 600 mm × D 300 mm, Wall 1.5 mm (door with stiffeners)
SPT1008030 — H 1000 mm × W 800 mm × D 300 mm, Wall 1.5 mm (door with stiffeners)
SPT12010030 — H 1200 mm × W 1000 mm × D 300 mm, Wall 1.5 mm (door with stiffeners)
SPT12010040 — H 1200 mm × W 1000 mm × D 400 mm, Wall 1.5 mm (door with stiffeners)
Configuration & Custom OptionsThe SPT enclosure is supplied empty for panel assembly. Standard supply: cold-rolled steel body and door, removable galvanized mounting plate, continuous PU door gasket, removable bottom gland plate with gasket, double-tooth lock, key and fixing hardware.
Custom options: modified height/width/depth, door cutouts for push-buttons/meters/switches/HMI, bottom or side cable-entry machining, mounting plate drilling to approved drawings, alternative coatings or stainless-steel construction for corrosive environments.
Installation Guide- Prepare the mounting plate: remove the galvanized plate, mark and fit DIN rails, wiring ducts and terminals; perform component mounting and pre-wiring outside the enclosure.
- Prepare cable entries: remove the bottom gland plate, drill or punch required holes, install suitable cable glands and reseat the gland plate gasket.
- Mount the enclosure: select wall brackets and fixings appropriate to wall material and load capacity; ensure level and secure installation.
- Complete assembly and grounding: reinstall mounting plate, finish internal wiring and connect door and enclosure grounding points; check lock, hinges and seals before operation.
ApplicationsDesigned to house control, protection, distribution and wiring components for industrial and commercial electrical systems; suitable for outdoor use when cable entries and cutouts are correctly sealed.
FAQ (selected)- How to choose the right enclosure: select by mounting plate layout, component depth, cable-entry requirements, heat dissipation and maintenance clearance; verify external and usable internal dimensions before ordering.
- Can cable-entry holes be customized: yes; gland plate machining can be customized to cable quantity, gland size and entry position.
- Will custom cable holes affect IP rating: they can; use suitable cable glands, sealing accessories and correctly installed gaskets to maintain IP protection.
Technical specifications- Protection rating: IP66
- Impact resistance: IK10
- Material: Cold-rolled steel body and door
- Mounting plate: Galvanized steel sheet (removable)
- Surface finish: Thermosetting powder coating, textured (standard RAL 7035)
- Door seal: Continuous PU foamed gasket
- Temperature range: -40°C to +80°C
- Locking: Double-tooth cylinder lock
- Cable entry: Removable bottom gland plate with sealing gasket
- Optional accessories: Grounding wire; painted steel or stainless-steel mounting brackets