OverviewPFAS-free composite membrane for medical microfiltration and venting. Multi-layer construction combines a nanofiber filtration layer with woven and knitted support layers to deliver controlled pore distribution, high permeability and reinforced mechanical stability.
Design & performanceThe patented SEFAR MEDITEX® PORE is supplied as hydrophobic or hydrophilic media. Homogeneous surface properties and a laminated 3-layer architecture (nanofiber + woven + knitted supports) enable consistent handling, stable performance and integration into single-use and process-critical medical devices.
Key benefits- High filtration efficiency
Nanofiber layer provides narrow pore size distribution and a high surface-to-volume ratio for reliable liquid filtration and particle retention. - Versatile surface options
Available hydrophobic, oleophobic or hydrophilic treatments to control fluid interaction per application. - Biocompatibility tested
Hydrophilic variants tested to USP Class VI, ISO 10993-5 (cytotoxicity) and ISO 10993-10 (skin irritation). - Mechanical reinforcement
Woven and knitted support layers provide dimensional stability for processing and assembly. - PFAS-free
No intentionally added PFAS to support regulatory and customer requirements. - Format flexibility
Supplied in multiple materials, formats and widths to match device designs and manufacturing workflows.
Hydrophilic features- High flow rates under gravity or applied pressure with minimal pressure drop.
- Consistent wettability for reproducible liquid handling.
- Biocompatibility test data: USP Class VI, ISO 10993-5, ISO 10993-10.
- REACH and RoHS compliance.
- Homogeneous thickness for predictable processing.
- Strong mechanical resistance for assembly and handling.
- Narrow pore distribution for precise liquid microfiltration.
Hydrophobic / Venting features- High air and steam permeability at low differential pressure while maintaining a high water column.
- Balanced air permeability and particle retention for effective venting.
- Narrow pore size distribution for stable gas/liquid separation.
- Biocompatibility testing for cytotoxicity (ISO 10993-5) and skin irritation (ISO 10993-10).
- REACH and RoHS compliance.
- Homogeneous thickness and robust mechanical resistance for durable integration.
Specifications (excerpt)Article | Air Permeability @200 Pa (L/m2/s) | Maximum Pore Size (µm) | Thickness (µm) | Water Column (mm) | Water Flux (ml/(cm2·min) @1 bar)
06-900 VHO | 34 | 0.9 | 280 | > 1000 | N/A
06-900 LHI | 34 | 0.9 | 280 | N/A | 450
ApplicationsDesigned for microfiltration and venting in medical devices, including single-use bioreactors, closed cell culture systems and fluid management components where biocompatibility and controlled permeability are required.
Technical characteristics- Construction: nanofiber filtration layer laminated to woven and knitted support layers (3-layer composite).
- PFAS status: free from intentionally added PFAS.
- Biocompatibility: USP Class VI (hydrophilic option), ISO 10993-5, ISO 10993-10.
- Compliance: REACH and RoHS.
- Surface treatments: hydrophobic, oleophobic, hydrophilic options available.
- Mechanical properties: reinforced for dimensional stability and secure handling.
- Formats: multiple materials, formats and widths for device-specific integration.
- Representative data: 06-900 VHO — Air permeability 34 L/m2/s @200 Pa; max pore 0.9 µm; thickness 280 µm; water column >1000 mm. 06-900 LHI — Air permeability 34 L/m2/s @200 Pa; max pore 0.9 µm; thickness 280 µm; water flux 450 ml/(cm2·min) @1 bar.