1. Metrology - Laboratory
  2. Laboratory Equipment
  3. Uniphos Envirotronic Pvt. Ltd.

Test strip D4071017

Test strip - D4071017 - Uniphos Envirotronic Pvt. Ltd.
Test strip - D4071017 - Uniphos Envirotronic Pvt. Ltd.
Add to favorites
Compare this product

Description

Product overview
As a gas detection company specializing in gas detection tubes and monitoring, Uniphos offers a selection of specialty detector tubes and detector strips designed for optimal performance, accuracy, dependability and ease-of-use. A wide variety of specialty tubes and strips for detection of numerous types of chemicals are available, together with pumps, sampling kits and accessories.

Airtester HP & MP Sets
Name | PN | Range | Spec
Airtester Adapter R 5/8" 200bar | D4071017 | N/A | N/A
Airtester Adapter R 5/8" 300bar | D4073018 | N/A | N/A
Airtester HP – Single Stage | D3188701 | N/A | N/A
Airtester MP – Medium Pressure – Single Stage | D5185710 | N/A | N/A
Carbon Dioxide CO2-HP | D5085848 | 100-2000 PPM | Datasheet available
Carbon Monoxide CO-HP | D5085847 | 5-70 PPM | Datasheet available
DT Oil-HP synth | 10040887 | Warning Marks | Datasheet available
H2O-HP (mg/m³) | D5085849 | 5-160 mg/m³ | N/A
H2O-MP | D5086851 | 100-1000 PPM | N/A
Nitr.-HP | D5086850 | 0.2-6 PPM | N/A
Water Vapor-HP | D7086872 | 5-200 mg/m³ | N/A
Airtester HP- Multi-Port Sampling Kit | D3188702 | N/A | N/A

Charcoal Tubes
Charcoal tubes (coconut shell GAC) for adsorption of organic vapors; conform to NIOSH standards.
Size | PN | DIM | Range
Standard | LCT-100 | 6 x 70 mm | 50/100 mg
Large | LCT-400 | 8 x 110 mm | 200/400 mg
Jumbo | LCT-800 | 10 x 110 mm | 200/800 mg
Open End Charcoal Tubes - Standard | LCT-101 | 6 x 70 mm | 50/100 mg
Open End - Large | LCT-401 | 8 x 110 mm | 200/400 mg
Open End - Jumbo | LCT-801 | 10 x 110 mm | 200/800 mg

CWA Tubes
Name | PN | Spec
Chloro Cyane | D5086884 | Datasheet available
HD | D5086882 | Datasheet available
HD, HN | D5086881 | Datasheet available
Lewisit | D5086883 | Datasheet available
Phosphoric acid ester | D5086880 | Datasheet available

Dissolved Ion Tubes (water)
Dissolved Ion Tubes provide rapid ionic chemical measurement in water; pre-calibrated; concentration read from color stain length.
Name | PN | SMR (standard measuring range) | Spec
Chloride Ion in Water | DCL-4L | 5 to 200 ppm | N/A
Chloride Ion in Water | DCL-5M | 10 to 2000 ppm | N/A
Chromium ion | DCR-2 | 1-50 mg/L | Datasheet available
Cyanide Ion | DCY-2 | 0.5-50 ppm | Datasheet available
Cyanide Ion | DCY-4M | 50-500 ppm | Datasheet available
Sulfide Ion in Water | DSU-2M | 0.5 to 20 ppm | N/A
Sulfide Ion in Water | DSU-3 | 1 to 100 ppm | N/A
Sulfide Ion in Water | DSU-4M | 2 to 300 ppm | N/A

Dosimeter Tubes
Dosimeter tubes measure cumulative dose (PPM·HR) over time; intended for area or personal exposure monitoring (lapel).
Name | PN | SMR / SMR units | Spec
Ammonia Dosimeter | LAM-2 | 25-500 PPM·HR | Datasheet available
Carbon Dioxide Dosimeter | LCD-2 | (5-120) x 10^3 PPM·HR | Datasheet available
Oxygen Dosimeter | LOX-1 | (1-100) x 150 PPM·HR | Datasheet available
Phosphine Dosimeter | LPG-1 | (1-200) x 10^3 PPM·HR | Datasheet available
Phosphine Dosimeter | LPG-2 | (1-200) x 10^2 PPM·HR | Datasheet available

Measurements in Compressed CO
Name | PN | SMR | Spec
Carbon Monoxide in CO2 | CCCO-2 | 1-50 ppm v/v | Datasheet available
Nitrogen Dioxide in CO2 | CCND-1H | 0.1-6 ppm v/v | Datasheet available

Mini CO Dosimeter Tube
Name | PN | Spec
Mini CO Dosimeter | D5091738 | Datasheet available

Gas Detector Strips
Low-cost, semi-quantitative strips for ambient air: place strip and estimate concentration from time-to-color-change.
Name | PN | SMR | Spec
Arsine Detector Strips | CF000155 | 0.5 to 3 ppm | Datasheet available
Hydrogen Cyanide Detector Strips | CF000156 | 1 to 20 ppm | Datasheet available
Hydrogen Sulfide Detector Strips | CF000157 | 1 to 20 ppm | Datasheet available
Mercaptan Detector Strips | CF000158 | 0.5 to 10 ppm | Datasheet available
Phosphine Detector Strips | CF000159 | 0.3 to 10 ppm | Datasheet available

High Pressure (HP) Tubes
High Pressure Tubes used with pressurized gas sources (not hand pump); sample volumes typically >1 L.
Name | PN | SMR | Spec
Carbon Dioxide-HP | D5085848 | 100-2000 ppm | Datasheet available
Carbon Monoxide-HP | D5085847 | 5-70 ppm | Datasheet available
Compressor Oil Vapor & Mist | 10040887 | 0.3-7.5 mg/m³ | Datasheet available
Water Vapor-HP | D7086872 | 5-200 mg/m³ | Datasheet available

PID Pre-Filter Tubes for Benzene - Butadiene
Tube Name | PN | SMR | SPEC
PID Pre-Filter Tube Benzene-0.05 | D7095863 | 0.05 to 200 ppm | N/A
URPID Pre-Filter Tube Benzene-0.05 (replacement) | PBE-1 | 0.05 to 200 ppm | Datasheet available
URPID Pre-Filter Tube Butadiene | PBU-1 | 0.1 to 200 ppm | Datasheet available
VOC Zeroing Tube Uniphos | VOC-1 | N/A | Datasheet available
VOC Zeroing Tube KwikDraw | D7086765 | N/A | Datasheet available

Smoke Generation Tubes (Air Flow Indicator Tubes)
Used for respirator fit testing or to visualize air flows (ducts, fume hoods). Stannic chloride type recommended by OSHA.
Uniphos Smoke Tubes | PN | SPEC | SDS
Uniphos Smoke Tubes | SMT-1 | Datasheet available | Safety data sheet available
Uniphos Smoke Tubes Kit | SMT-K | N/A | Safety data sheet available
KwikDraw smoke accessories, cartridges and kit entries are available for corrosive and non-corrosive smoke tubes (various PNs).

Accessories
Uniphos Tube Accessories (examples):
Item | PN
ASP-40 Piston Hand Pump | ASP-40
Pump kit ASP-40 kit | ASP-40K
ASP-21 Piston Hand Pump | ASP-21
Pump kit ASP-21 kit | ASP-21K
Rebuild kit for ASP series pump | REBUILDKIT
Grease for ASP series hand pump | GREASE
Inlet adapters, plunger gaskets, tube tip cutter, stainless steel gas sampling bulb (BULBSS), etc.

Notes
- Many individual tube types cover detection of gases (CO2, CO, H2S, PH3, HCN, arsine, mercaptans, VOCs) and ionic species in water (chloride, cyanide, chromium, sulfide).
- Product lists include item names, part numbers (PN), standard measuring ranges (SMR) or ranges in PPM / mg/m3 as shown above.

caractéristiques / spécifications techniques
  • Brand: Uniphos Envirotronic (Uniphos)
  • Product family: Specialty detector tubes, detector strips, charcoal tubes, CWA tubes, dosimeter tubes, high-pressure tubes, PID pre-filters, smoke tubes and accessories
  • Measurement types: gas-phase toxicants and irritants (CO, CO2, H2S, PH3, HCN, arsine, mercaptans, VOCs), compressor oil vapors/mists, water ionic species (chloride, cyanide, chromium, sulfide), dosimetry (PPM·HR)
  • Typical measuring units and ranges: PPM, mg/m³, PPM·HR; representative ranges include 0.3–7.5 mg/m³ (oil vapor), 5–70 ppm (CO-HP), 100–2000 ppm (CO2-HP), 0.3–10 ppm (phosphine strips), 0.5–3 ppm (arsine strips), 0.05–200 ppm (PID pre-filters)
  • Format variants: standard, large, jumbo charcoal tubes (various dimensions: 6x70 mm, 8x110 mm, 10x110 mm)
  • Accessories: piston hand pumps (ASP-40, ASP-21), pump kits, sampling lines, inlet adapters, tip cutters, bulb samplers, rebuild kits, grease, KwikDraw pumps and kits
  • Intended use: spot measurements, semi-quantitative ambient checks (strips), cumulative exposure monitoring (dosimeter tubes), pressurized-gas analysis (HP tubes), water ionic analysis (dissolved ion tubes)
  • Datasheets / technical documents: available per individual tube / strip (datasheets referenced on product listings)

Catalogs

No catalogs are available for this product.

See all of Uniphos Envirotronic Pvt. Ltd.‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.