Product overviewAs a gas detection company specializing in gas detection tubes and monitoring, Uniphos offers a selection of specialty detector tubes and detector strips designed for optimal performance, accuracy, dependability and ease-of-use. A wide variety of specialty tubes and strips for detection of numerous types of chemicals are available, together with pumps, sampling kits and accessories.
Airtester HP & MP SetsName | PN | Range | Spec
Airtester Adapter R 5/8" 200bar | D4071017 | N/A | N/A
Airtester Adapter R 5/8" 300bar | D4073018 | N/A | N/A
Airtester HP – Single Stage | D3188701 | N/A | N/A
Airtester MP – Medium Pressure – Single Stage | D5185710 | N/A | N/A
Carbon Dioxide CO2-HP | D5085848 | 100-2000 PPM | Datasheet available
Carbon Monoxide CO-HP | D5085847 | 5-70 PPM | Datasheet available
DT Oil-HP synth | 10040887 | Warning Marks | Datasheet available
H2O-HP (mg/m³) | D5085849 | 5-160 mg/m³ | N/A
H2O-MP | D5086851 | 100-1000 PPM | N/A
Nitr.-HP | D5086850 | 0.2-6 PPM | N/A
Water Vapor-HP | D7086872 | 5-200 mg/m³ | N/A
Airtester HP- Multi-Port Sampling Kit | D3188702 | N/A | N/A
Charcoal TubesCharcoal tubes (coconut shell GAC) for adsorption of organic vapors; conform to NIOSH standards.
Size | PN | DIM | Range
Standard | LCT-100 | 6 x 70 mm | 50/100 mg
Large | LCT-400 | 8 x 110 mm | 200/400 mg
Jumbo | LCT-800 | 10 x 110 mm | 200/800 mg
Open End Charcoal Tubes - Standard | LCT-101 | 6 x 70 mm | 50/100 mg
Open End - Large | LCT-401 | 8 x 110 mm | 200/400 mg
Open End - Jumbo | LCT-801 | 10 x 110 mm | 200/800 mg
CWA TubesName | PN | Spec
Chloro Cyane | D5086884 | Datasheet available
HD | D5086882 | Datasheet available
HD, HN | D5086881 | Datasheet available
Lewisit | D5086883 | Datasheet available
Phosphoric acid ester | D5086880 | Datasheet available
Dissolved Ion Tubes (water)Dissolved Ion Tubes provide rapid ionic chemical measurement in water; pre-calibrated; concentration read from color stain length.
Name | PN | SMR (standard measuring range) | Spec
Chloride Ion in Water | DCL-4L | 5 to 200 ppm | N/A
Chloride Ion in Water | DCL-5M | 10 to 2000 ppm | N/A
Chromium ion | DCR-2 | 1-50 mg/L | Datasheet available
Cyanide Ion | DCY-2 | 0.5-50 ppm | Datasheet available
Cyanide Ion | DCY-4M | 50-500 ppm | Datasheet available
Sulfide Ion in Water | DSU-2M | 0.5 to 20 ppm | N/A
Sulfide Ion in Water | DSU-3 | 1 to 100 ppm | N/A
Sulfide Ion in Water | DSU-4M | 2 to 300 ppm | N/A
Dosimeter TubesDosimeter tubes measure cumulative dose (PPM·HR) over time; intended for area or personal exposure monitoring (lapel).
Name | PN | SMR / SMR units | Spec
Ammonia Dosimeter | LAM-2 | 25-500 PPM·HR | Datasheet available
Carbon Dioxide Dosimeter | LCD-2 | (5-120) x 10^3 PPM·HR | Datasheet available
Oxygen Dosimeter | LOX-1 | (1-100) x 150 PPM·HR | Datasheet available
Phosphine Dosimeter | LPG-1 | (1-200) x 10^3 PPM·HR | Datasheet available
Phosphine Dosimeter | LPG-2 | (1-200) x 10^2 PPM·HR | Datasheet available
Measurements in Compressed COName | PN | SMR | Spec
Carbon Monoxide in CO2 | CCCO-2 | 1-50 ppm v/v | Datasheet available
Nitrogen Dioxide in CO2 | CCND-1H | 0.1-6 ppm v/v | Datasheet available
Mini CO Dosimeter TubeName | PN | Spec
Mini CO Dosimeter | D5091738 | Datasheet available
Gas Detector StripsLow-cost, semi-quantitative strips for ambient air: place strip and estimate concentration from time-to-color-change.
Name | PN | SMR | Spec
Arsine Detector Strips | CF000155 | 0.5 to 3 ppm | Datasheet available
Hydrogen Cyanide Detector Strips | CF000156 | 1 to 20 ppm | Datasheet available
Hydrogen Sulfide Detector Strips | CF000157 | 1 to 20 ppm | Datasheet available
Mercaptan Detector Strips | CF000158 | 0.5 to 10 ppm | Datasheet available
Phosphine Detector Strips | CF000159 | 0.3 to 10 ppm | Datasheet available
High Pressure (HP) TubesHigh Pressure Tubes used with pressurized gas sources (not hand pump); sample volumes typically >1 L.
Name | PN | SMR | Spec
Carbon Dioxide-HP | D5085848 | 100-2000 ppm | Datasheet available
Carbon Monoxide-HP | D5085847 | 5-70 ppm | Datasheet available
Compressor Oil Vapor & Mist | 10040887 | 0.3-7.5 mg/m³ | Datasheet available
Water Vapor-HP | D7086872 | 5-200 mg/m³ | Datasheet available
PID Pre-Filter Tubes for Benzene - ButadieneTube Name | PN | SMR | SPEC
PID Pre-Filter Tube Benzene-0.05 | D7095863 | 0.05 to 200 ppm | N/A
URPID Pre-Filter Tube Benzene-0.05 (replacement) | PBE-1 | 0.05 to 200 ppm | Datasheet available
URPID Pre-Filter Tube Butadiene | PBU-1 | 0.1 to 200 ppm | Datasheet available
VOC Zeroing Tube Uniphos | VOC-1 | N/A | Datasheet available
VOC Zeroing Tube KwikDraw | D7086765 | N/A | Datasheet available
Smoke Generation Tubes (Air Flow Indicator Tubes)Used for respirator fit testing or to visualize air flows (ducts, fume hoods). Stannic chloride type recommended by OSHA.
Uniphos Smoke Tubes | PN | SPEC | SDS
Uniphos Smoke Tubes | SMT-1 | Datasheet available | Safety data sheet available
Uniphos Smoke Tubes Kit | SMT-K | N/A | Safety data sheet available
KwikDraw smoke accessories, cartridges and kit entries are available for corrosive and non-corrosive smoke tubes (various PNs).
AccessoriesUniphos Tube Accessories (examples):
Item | PN
ASP-40 Piston Hand Pump | ASP-40
Pump kit ASP-40 kit | ASP-40K
ASP-21 Piston Hand Pump | ASP-21
Pump kit ASP-21 kit | ASP-21K
Rebuild kit for ASP series pump | REBUILDKIT
Grease for ASP series hand pump | GREASE
Inlet adapters, plunger gaskets, tube tip cutter, stainless steel gas sampling bulb (BULBSS), etc.
Notes- Many individual tube types cover detection of gases (CO2, CO, H2S, PH3, HCN, arsine, mercaptans, VOCs) and ionic species in water (chloride, cyanide, chromium, sulfide).
- Product lists include item names, part numbers (PN), standard measuring ranges (SMR) or ranges in PPM / mg/m3 as shown above.
caractéristiques / spécifications techniques- Brand: Uniphos Envirotronic (Uniphos)
- Product family: Specialty detector tubes, detector strips, charcoal tubes, CWA tubes, dosimeter tubes, high-pressure tubes, PID pre-filters, smoke tubes and accessories
- Measurement types: gas-phase toxicants and irritants (CO, CO2, H2S, PH3, HCN, arsine, mercaptans, VOCs), compressor oil vapors/mists, water ionic species (chloride, cyanide, chromium, sulfide), dosimetry (PPM·HR)
- Typical measuring units and ranges: PPM, mg/m³, PPM·HR; representative ranges include 0.3–7.5 mg/m³ (oil vapor), 5–70 ppm (CO-HP), 100–2000 ppm (CO2-HP), 0.3–10 ppm (phosphine strips), 0.5–3 ppm (arsine strips), 0.05–200 ppm (PID pre-filters)
- Format variants: standard, large, jumbo charcoal tubes (various dimensions: 6x70 mm, 8x110 mm, 10x110 mm)
- Accessories: piston hand pumps (ASP-40, ASP-21), pump kits, sampling lines, inlet adapters, tip cutters, bulb samplers, rebuild kits, grease, KwikDraw pumps and kits
- Intended use: spot measurements, semi-quantitative ambient checks (strips), cumulative exposure monitoring (dosimeter tubes), pressurized-gas analysis (HP tubes), water ionic analysis (dissolved ion tubes)
- Datasheets / technical documents: available per individual tube / strip (datasheets referenced on product listings)