OverviewThe X Series geophones are single-axis sensors designed for seismic and vibration acquisition in industrial exploration, civil engineering and hydrological studies. Vertical orientation versions are available; suitable for array deployment and field surveys.
Applications- Oil and coal exploration
- Civil and geotechnical engineering monitoring
- Hydrological vibration analysis
- Seismic data acquisition and array surveys
Product categoryMedium frequency geophones (nominal range 4.5 Hz–14 Hz); vertical orientation available.
Models and specificationsModel: PS-7X | PS-8X | PS-10X | PS-14X
Frequency (Hz): 7±0.5 | 8±0.5 | 10±5% | 14±5%
Resistance (Ω): 395±5% each model
Sensitivity (V/m/s): 28.6±5% | 28.0±5% | 28.0±5% | 28.0±5%
Parallel-resistance sensitivity (V/m/s): 24.6±5% (2400 Ω) | 23.0±5% (1800 Ω) | 20.1±5% (1000 Ω) | 20.1±5% (1000 Ω)
Damping: 0.428±5% | 0.38±5% | 0.299±5% | 0.22±5%
Parallel-resistance damping: 0.73±5% (2400 Ω) | 0.71±5% (1800 Ω) | 0.706±5% (1000 Ω) | 0.510±5% (1000 Ω)
Distortion (%): ≤0.3 | ≤0.2 | ≤0.2 | ≤0.2
Spurious/false frequency: ≥180 | ≥200 | ≥200 | ≥280
Maximum acceleration limit: 1.5 g each model
Inertial mass: 11 (as specified)
Dimensions (d × h) mm: 25.4 × 34 each model
Operating temperature: -40 °C to +70 °C
Shelf life: 1 year
Weight (g): 87.3 | — | 87.4 | 87.4
Notes- Damage caused by high voltage or physical impact is excluded from warranty coverage.
- Product specifications may be updated without prior notice.
Key features / technical highlights- Series: X Series — available models PS-7X, PS-8X, PS-10X, PS-14X.
- Nominal frequencies covering 7–14 Hz for medium-frequency seismic acquisition.
- Standard nominal resistance ~395 Ω; parallel-resistance sensitivity and damping values provided for impedance matching.
- Low distortion and high spurious frequency performance for reliable seismic data.
- Compact dimensions (25.4 × 34 mm) and wide operating temperature range (-40 °C to +70 °C) for field deployment.
- Maximum acceleration limit 1.5 g and inertial mass 11 for stable dynamic response.
Ordering & compatibility- Select model according to center frequency and the recording-system input impedance (reference parallel resistances shown).
- Mounting: compatible with standard geophone bases and array frames; verify orientation (vertical version available).
- Storage and shelf life: recommended storage conditions to preserve sensor performance; check weight and dimensions when integrating into arrays.