Trigger voltage: 100 V - 240 V
... Series arc-flash relay is a cost-effective solution that reduces arc-fault damage by detecting the light from an arc flash and rapidly tripping. Two remote light sensors can be connected to one relay and multiple AF0100 ...
Littelfuse
Trigger voltage: 110, 250, 100, 240 V
... The AF0500 is a microprocessor-based arc-flash protection relay that limits arc-fault damage by detecting the light from an arc flash and rapidly tripping the feeder breaker. The unit is well suited for switchgear, transformer, ...
Littelfuse
Trigger voltage: 12, 48, 120, 240 V
... -8800 is a microprocessor-based relay that limits arc-fault damage by detecting the light from an arc flash and rapidly tripping. Phase-current-transformer inputs are provided for current-constrained arc-flash protection ...
Littelfuse
... circuit breakers with a 220/250 Vdc shunt trip coil. The D0920 has one output indication relay with an isolated normally-open contact, and one output indication relay with an isolated normally-closed contact. Additional ...
Littelfuse
Trigger voltage: 120, 230 V
... electric modular relays. It is specifically designed for direct pulse currents. Its delay time and sensitivity can be adjusted, with near-immunity to external interruptions. The relay is built in a modular size, and can ...
FANOX ELECTRONIC
Tripping current: 4 A - 91 A
Trigger voltage: 230, 24, 115 V
... comes with a three-year guarantee. The relay works well for motors that need protection for every type of start. This relay is specially applicable to protect motor which need dependable and accurate ...
FANOX ELECTRONIC
Tripping current: 60 A - 200 A
Trigger voltage: 24, 115, 230 V
... FANOX integral motor protection relays - gl relay is suitable for 3-phase motors between 60 to 200 A and above. Cable feed is through relay. Its thermal image is reproduced due to the ...
FANOX ELECTRONIC
Trigger voltage: 400, 440, 230 V
... 630 A and over. It has a cable feed, visual indicator of the tripping cause, adjustable reset time for cos φ, and timer module PF-RM. Unit has accurate motor heating and cooling memory that will reproduce the thermal image. ...
FANOX ELECTRONIC
Trigger voltage: 230, 115 V
... pumps (irrigation, well de-watering, gas stations), as well as surface pumps and other applications like ventilators and conveyor belts. ...
FANOX ELECTRONIC
Trigger voltage: 120, 230, 24 V
... The ELR-A Series, manufactured by Fanox, is a differential earth leakage protection reclosing relay that is equipped with DIN rail mounting, rated sensitivity from 0.025 to 25 A, time ...
FANOX ELECTRONIC
Trigger voltage: 120, 230, 24 V
... These relays are compact and have trip delay times of 0.02-5s. They respond to current from 0.025-25A. The units have an integrated toroidal transformer that is 60mm and 110mm. They are suited for use in motor centers (MCC). ...
FANOX ELECTRONIC
Trigger voltage: 24 V - 400 V
... differential earth leakage protection reclosing relay that is equipped with EN-50022-35 DIN rail mounting and front cover. This provides a reclosure of an AC and DC electronic breaker ...
FANOX ELECTRONIC
Trigger voltage: 120, 230, 24 V
... an electronic relay that comes with an automatic reclosing of 3 attempts. The device has a delay time and sensitivity that can be adjustable. It is already resistant to outer disturbances, and has a high level of immunity. The relay ...
FANOX ELECTRONIC
Trigger voltage: 230 V
... temperature regulator controlled by thermistors. It provides protection to the motor from over-temperature and insufficient ventilation or cooling. The device is equipped with an external module and DIN rail ...
FANOX ELECTRONIC
Tripping current: 5 A
Trigger voltage: 250 V
... differential protection and short-circuit protection relay for generator protection against internal short circuits (leaking currents). The MDR-2 is a state-of-the-art combined differential ...
DEIF
Tripping current: 8 A
Trigger voltage: 250 V
... overvoltage relay, U DEIF's RMV protective voltage relays are applied for generator, motor and transformer protection against adverse system voltage conditions. The versatile unit ...
DEIF
Tripping current: 8 A
Trigger voltage: 250 V
... DEIF's RMV protective voltage relays are applied for generator, motor and transformer protection against adverse system voltage conditions. The versatile unit features a number of adjustable parameters. DEIF's ...
DEIF
Tripping current: 8 A
Trigger voltage: 250 V
... DEIF's differential current relay RMC-131D protects the generator against short circuits and leakage currents in the windings of the generator. DEIF’s differential current relay RMC-131D protects the generator against ...
DEIF
Tripping current: 8 A
Trigger voltage: 250 V
... earth faults in the generator’s stator. The relay also protects against loss of excitation in case of earth fault in the stator. The RMC-142D is part of DEIF’s complete range of relays for protection ...
DEIF
Tripping current: 8 A
Trigger voltage: 250 V
... The RMP-111D is a protective overload power relay for generator and prime mover protection. The RMP-111D is a protective overload power relay for generator and prime ...
DEIF
Tripping current: 8 A
Trigger voltage: 250 V
... DEIF's RMV protective voltage relays are applied for generator, motor and transformer protection against adverse system voltage conditions. The versatile unit features a number of adjustable parameters. DEIF's ...
DEIF
Tripping current: 8 A
Trigger voltage: 250 V
... Excitation Relay/Over-excitation Relay This Uni-line relay protects generators running in parallel with other generators from running as an induction generator due to under-excitation – particularly ...
DEIF
... DEIF's loss of mains relays protect generators against damage resulting from a non-synchronised reconnection to the grid after a temporary mains failure. DEIF's loss of mains relays protect generators against damage ...
DEIF
... DEIF's loss of mains relays protect generators against damage resulting from a non-synchronised reconnection to the grid after a temporary mains failure. DEIF's loss of mains relays protect generators against damage ...
DEIF
Tripping current: 5 A
... Protection relay against overload, underload, and phase loss. With display. Codes and references - 10002217 TPM5-230 - 10002218 TPM5-400 - 10002451 TPM5/5-230 - 10002452 TPM5/5-400 Specifications - Power ...
Toscano Linea Electronica
Tripping current: 0 A - 40 A
... Control and protection module for motors and pumps. - Protections: overload, underload, phase and level failure. - 0…40A 230/400VAC - Level relay and pressure switch connections Codes and references - ...
Toscano Linea Electronica
Tripping current: 0.5 A - 20 A
... thermal protection with automatic setting of motor overload and underload. External On/Off control of spotlights and scene change function (RGB). External On/Off control of the pump. Forced pump Start/Stop in manual mode. Integrated frost ...
Toscano Linea Electronica
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription