Avantes near-infrared spectrometers
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Wavelength: 200 nm - 1,160 nm
Length: 175 mm
Width: 127 mm
... , uncooled AvaSpec-ULS2048x64-EVO. With its standard 2048×64 back-thinned detector, this spectrometer is perfect for less demanding applications in the UV and NIR ranges. The cooling option is often ...
Avantes
Wavelength: 200 nm - 1,160 nm
Length: 175 mm
Width: 127 mm
... AvaSpec-ULS2048XL EVO spectrometer. Unlike many back-thinned CCD spectrometers with two-dimensional arrays, the ULS2048XL-EVO has large monolithic pixels of 14×500 microns with exceptional efficiency ...
Avantes
Wavelength: 900 nm - 1,750 nm
Length: 185 mm
Width: 84 mm
For measurements in the near-infrared range up to 1.7 µm, Avantes offers a new series of uncooled spectrometer configurations. The AvaSpec-NIR256-1.7-EVO and the AvaSpec-NIR512-1.7-EVO ...
Avantes
Wavelength: 900 nm - 1,700 nm
Length: 185 mm
Width: 145 mm
For measurements in the near-infrared range up to 1.7 µm, Avantes offers a new series of cooled spectrometer configurations. The AvaSpec-NIR256-1.7-HSC-EVO and the AvaSpec-NIR512-1.7-HSC-EVO ...
Avantes
Wavelength: 1,000 nm - 2,500 nm
Length: 185 mm
Width: 145 mm
The new and improved versions of our NIR spectrometers offer higher sensitivity, lower weight, and a smaller size. They are based on a 100mm optical bench with an NA of 0.13, offering optimum balance ...
Avantes
Wavelength: 1,000 nm - 2,500 nm
Length: 100, 95, 185 mm
Width: 130, 68, 145 mm
... specifications of the NIR optical benches are listed in the table below. The NIR AvaBenches are fully compatible with Avantes’ electronics boards or may be interfaced to customer-specific electronics. ...
Avantes
Wavelength: 785 nm
... is recommended (higher quantum efficiency in NIR and better signal-to-noise performance). When weak Raman signals occur (integration time longer than 5 seconds), the thermo-electric-cooled (TEC) spectrometer ...
Avantes
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining