CIRCUTOR dry transformers
The PRO CT series offers a range of solid core current transformers. The inepro solid core current transformers are perfectly suitable for installation in combination with a PRO380 CT smart energy meter. ...
... voltage and current transformers customized to our customers’ technical specifications. Open style circuit board transformers Open style circuit board transformers are used as - ...
Muuntosähkö Oy - Trafox
Electric power: 0.04 W - 5 W
Primary voltage: 230, 400 V
Secondary voltage: 24 V - 230 V
... isolating / isolation transformers, which are protected against direct contact. Products in the LH-series are designed with maximum versatility in every transformer’s functions and technical features. ...
Muuntosähkö Oy - Trafox
Primary voltage: 230, 400 V
Secondary voltage: 24 V - 230 V
Frequency: 50, 60 Hz
... isolating / isolation transformers, which are protected against direct contact. Products in the XH-series are designed with maximum versatility in every transformer’s functions and technical features. ...
Muuntosähkö Oy - Trafox
Primary current: 20 A - 5,000 A
Secondary current: 5 A
Frequency: 50 Hz - 60 Hz
UA-CTR Round Current Transformer Primary current: 20-5000A Secondary current: 5A UA-CT offers a complete range of high quality current transformers suitable for low voltage (LV) applications to ...
Primary current: 30 A - 3,000 A
Secondary current: 5 A
Frequency: 50, 60 Hz
UA-CTS Square Current Transformer Primary current: 30-3000A Secondary current: 5A UA-CTS offers a complete range of high quality current transformers suitable for low voltage (LV) applications to ...
Primary current: 60 A - 630 A
Secondary current: 5, 1 A
Frequency: 50 Hz - 60 Hz
3-in-1 Solid Type CE/ROHS Approved Electrical Specifications • Insulation Voltage : 720V AC • Measurement Range : 20%In~120%In • Accuracy : Class 0.5/Class 1 • Dielectric Strength : 3.0kV/1mA/1min Mechanical Specifications • ...
TAB1- closed current transformers /5A TAB1: Closed version current transformer for low voltage systems Advantages of purchasing: Secondary with double faston 6.3 x 0.8 mm Possibility of inserting ...
DOSSENA
TAB2 - closed current transformers /5A TAB2: Closed version current transformer for low voltage systems Advantages of purchasing: Secondary with double faston 6.3 x 0.8 mm Possibility of inserting ...
DOSSENA
TAB3 - closed current transformers /5A TAB3: Closed version current transformer for low voltage systems Advantages of purchasing: Secondary with double faston 6.3 x 0.8 mm Possibility of inserting ...
DOSSENA
Output power kVA: 0 kVA - 2,500 kVA
Primary voltage: 10, 35 kV
10~35kV tower tube built-in water-cooled dry-type transformer Scope of application: All series of products are suitable for 10kV and 35kV power transmission and distribution systems, and can be used ...
Ningbo Tianan (Group) CO.,Ltd.
Output power kVA: 50 kVA - 2,500 kVA
Scope of application: SC series dry-type transformers can be used as replacement products for oil-immersed transformers. Especially suitable for high-rise buildings, commercial centers, ...
Ningbo Tianan (Group) CO.,Ltd.
Output power kVA: 30 kVA - 2,500 kVA
Primary voltage: 10, 20, 35 kV
... and rural areas. The low voltage coil of the transformer is wound with copper foil or semi-hard copper wire, which enhances the ability of the transformer to withstand short circuits The transformer ...
Ningbo Tianan (Group) CO.,Ltd.
Primary voltage: 720 V
Primary current: 5 A
Secondary current: 5, 1 A
... wound CT A current transformer is used to reduce the primary current to a standardised value (1 or 5 A) in order to adapt to the current inputs of multifunction meters, energy meters and transducers. Frer current ...
ZELEC
Primary voltage: 720 V
Primary current: 10 A
Secondary current: 1, 5 A
... wound CT A current transformer is used to reduce the primary current to a standardised value (1 or 5 A) in order to adapt to the current inputs of multifunction meters, energy meters and transducers. Frer current ...
ZELEC
Primary voltage: 720 V
Primary current: 15 A
Secondary current: 5, 1 A
... wound CT A current transformer is used to reduce the primary current to a standardised value (1 or 5 A) in order to adapt to the current inputs of multifunction meters, energy meters and transducers. Frer current ...
ZELEC
Electric power: 50 W - 2,000,000 W
Primary voltage: 1 V - 1,000 V
Secondary voltage: 1 V - 1,000 V
The single-phase and three-phase transformers and auto-transformers are equipped with either copper or aluminum windings. These units feature air-type cooling and can perform up to 2000 kVA, with a frequency ...
Electric power: 50 W - 2,000,000 W
Primary voltage: 1 V - 1,000 V
Secondary voltage: 1 V - 1,000 V
Our 1-Ph and 3-Ph insulation transformers are designed to meet the following priority requirements: Anti-jamming screening between the primary and secondary windings Cooling: air type Power: up to ...
Primary voltage: 220 V
Secondary voltage: 220, 380, 440 V
The PTU-03 Isolation Transformer Module is an optional add on accessory for the ECU-02 or AVR. Compatible with single and three phase voltage and isolates the primary and secondary voltage. The Voltage Transfer Rates ...
Electric power: 0.1 kVA - 0.4 kVA
Primary voltage: 208 V - 480 V
Secondary voltage: 220 V
ATS Transformer Module is designed with pluggable terminal block to simplify ATS installation. Best use for system voltage 208 to 480 Vac. For system voltage from 208 to 480 Vac Modular design, simplify ATS ...
Electric power: 9,000 W
Primary voltage: 400 V
Secondary voltage: 223 V
SINGLE PHASE TRANSFORMER WITH INTEGRATED CHOKE Primary: 400V – Secondary: 223V – Power: 9KVA – Choke: 1,68mH Russian inter-cities train application (auxiliary converter) Boige et Vignal
Output power kVA: 0.005, 0.0015, 0.0038, 0.0025 kVA
Primary voltage: 1.2 kV
Secondary voltage: 720 V
• This Winding current transformer is mostly used for new installations, as the circuit must be interrupted here. • Most cost-effective and most common variant • Currently the most compact design on the market, thus ...
Celsa
Output power kVA: 0.001 kVA - 0.0075 kVA
Primary voltage: 1.2 kV
Secondary voltage: 720 V
• This clip-on current transformer is mostly used for new installations, as the circuit must be interrupted here. • Most cost-effective and most common variant • Simply plug the transformer onto ...
Celsa
Output power kVA: 0.001, 0.0015, 0.002, 0.0025, 0.005 kVA
Primary voltage: 1.2 kV
Secondary voltage: 720 V
• This calibrated current transformer is suitable for billing purposes • The design is approved by the Physikalisch Technische Bundesanstalt (PTB) Braunschweig • This transformer is mostly used for ...
Celsa
Primary voltage: 12, 11, 10 kV
Secondary voltage: 100 V - 240 V
Frequency: 60, 50 Hz
Description: This product is fully enclosed outdoor single-phase voltage transformer, epoxy resin and silicone rubber composite insulation pillar structure, the outer sheath and umbrella skirt are made of high temperature ...
Primary voltage: 66 kV - 500 kV
Frequency: 50, 60 Hz
... protection, provide voltage signals for control devices. Electronic transformer is the trend of meter transformer development. Contrast to the conventional instrument transformer, electronic ...
Siyuan Electric Co., Ltd
Frequency: 50, 60 Hz
Capacitor voltage transformer series products are suitable for current, electric energy measurement and relay protection in a system with effectively earthed neutral with rated voltage 35kV to 1000 kV and rated frequency ...
Siyuan Electric Co., Ltd
Primary voltage: 35 kV - 500 kV
Primary current: 4,000 A
Frequency: 50, 60 Hz
LVQB series current transformer has an inverted structure with SF6 gas insulation (Please see the figure). It is connected in series with electric energy measurement, measuring, and relay protection functions. Environment: ...
Siyuan Electric Co., Ltd
Output power kVA: 0.01 kVA
Primary current: 5 A
- Ratio x/5A - Accuracy class 0.5 and 0.2S Screw mounting
Primary current: 16 A
Partial Discharge High Frequency Current Transformer – Clamp on, clamp off for live machine fittings ø30mm and ø50mm The HFTC-0030 and HFTC-0050 Partial Discharge High Frequency Current Transformers ...
Primary current: 16, 10 A
Partial Discharge High Frequency Current Transformer – ø17mm and ø24mm The HFT-0017 and HFT-0024 Partial Discharge High Frequency Current Transformers are ideally suited for Partial Discharge measurements ...
Primary current: 100 A - 5,000 A
Small size and easy mounting. Range output burden: 100A - 5000A. High accuracy and reliability. TECHNICAL SPECIFICATION - Indoor use. - Policarbonate with self-extinguishing V0. - Sealable secondary terminals. - Highest voltage ...
Contrel elettronica
Primary current: 1 A - 4,000 A
... accessories supplied with the CT, Measuring Transformers: the short circuit on terminals or the connection to earth can be achieved by the double fast-on or connecting two wires on the same terminal. And Protection Transformers: ...
Contrel elettronica
Primary current: 500 A - 6,000 A
The TCB-A is a series of current transformers that are specially made for applications that involve power centers and distribution boards for plant expansion or maintenance. The primary bar does not need to be disconnected ...
Contrel elettronica
Primary current: 0 A - 2 A
Secondary current: 0 mA - 2 mA
Frequency: 50 Hz
Mini Voltage Transformer Occasion of use: Generally used in instruments and meters with high space requirements for testing voltage, electric energy and power; Principle of use: Primary and secondary 2 mA: 2 mA current, ...
Primary current: 5 A - 200 A
Secondary current: 2 mA - 200 mA
Frequency: 50, 60 Hz
Mini PCB Current Transformer Generally used in measuring instruments, as the secondary transformer of the instrument, convert 1 A, 5 A into mA current, For instrument use; Specifications Current ...
Primary voltage: 0.7 kV
Primary current: 60 A - 5,000 A
Secondary current: 5, 1 A
... protects them against accidental contact. -A complete set of accessories in a standard enabling wall mounting of the transformer. External dimension: depends on version
Output power kVA: 1 kVA - 1,000 kVA
Primary voltage: 230, 400 V
Secondary voltage: 230, 400 V
... 2500V • 1KVA-500KVA power range • 3 Phases, 2 Phases and 1 Phase input • Galvanic Isolation Transformer • Supply transformers • Voltage changing transformers Optional Features • ...
Electric power: 10 kVA
Primary voltage: 220, 380 V
Secondary voltage: 380, 220 V
... Copper Insulation :F/H Standard: EN61558-2-6 Range :30kva to as you requested Application : electrical control transformer
Shenzhen Sikes Electric Co., Ltd.
Output power kVA: 4 kVA
Primary voltage: 440 V
Secondary voltage: 380 V
Power Isolation transformer: Power isolation transformer refers to the input and output winding with electrical isolation transformers, it can avoid accidental hit at the same time transformer ...
Shenzhen Sikes Electric Co., Ltd.
Output power kVA: 12.5 kVA
Primary voltage: 380 V
Secondary voltage: 380 V
Photovoltaic isolation transformer encapsulated 12.5Kva for solar power or wind power transmission Description of Power Isolation transformer: SGGF isolation transformer is used to ...
Shenzhen Sikes Electric Co., Ltd.
Primary voltage: 0 kV - 0.7 kV
Secondary voltage: 0 kV - 0.7 kV
Primary current: 50 A - 6,000 A
Cable/Bus-bar type current transformer with DIN-rail/busbar and panel mounting facility. Rated primary currents from 50 A to 6000A(depends on the model). Secondary current is availabe in 5A or 1A. The accuracy of the ...
... widespread use of chordn transformer. Design: Open frame, stationary, for device installation and assembly in dry rooms, separate windings. Connection to leakage current-resistant transformer ...
Primary current: 2,500 A - 4,000 A
12 - 24 kV Block Type Design Standard: IEC 60044-1/6, VDE0414, ANSI, GOST On request with capacitive layer On request with barrier
alce elektrik san ve tic as
Electric power: 0.005 kVA - 0.1 kVA
Primary voltage: 12 kV - 36 kV
Secondary voltage: 100 V - 120 V
12-36 kV Single Pole Insulated Standard: IEC 60044-2, VDE 0414, ANSI, GOST
alce elektrik san ve tic as
Primary voltage: 36 kV
Secondary voltage: 70 V - 170 V
Primary current: 3,000 A
36 kV Block Type Design Standard: IEC 60044-1/6, VDE0414, ANSI, GOST On request with capacitive later On request with barrier
alce elektrik san ve tic as
Primary current: 200 A
Function: Transformers are components for detecting residual currents in connection with evaluation units such as DRCM, DMRCD or MFR. Transformers in combination with evaluation units are suitable for ...
Doepke Schaltgeräte GmbH
Electric power: 0.5 kVA - 160 kVA
Three-phase Transformers designed and manufactured to comply with IEC61558 and IEC60076. These are double-wound Isolation Transformers for continuous duty and complete with earth screen between the primary ...
Boardman Transformers
Electric power: 0.05 kVA - 2.5 kVA
Primary voltage: 0 V - 440 V
Secondary voltage: 12, 24, 48, 110, 230 V
CL Range CL Range Control Panel Transformers offering 230V with input tappings or 400V with input tappings. Designed and manufactured to comply with IEC61558. This high quality product is manufactured using automated ...
Boardman Transformers
Electric power: 0.05 kVA - 2.5 kVA
Primary voltage: 15 V - 400 V
Secondary voltage: 0 V - 230 V
MCL Range MCL Range Control Panel Transformers offering 230V and 400V with adjustment tappings. Designed and manufactured to comply with IEC61558. This high quality product is manufactured using automated winding and ...
Boardman Transformers
Primary current: 200 mA
Characteristics:Sub-plate mount,crimping terminal output, with built-in transient voltage suppressor for protection. purose:used for leakage current protection(EGR)zero sequence current detection.
YHDC Dechang Electric
Primary voltage: 230, 220, 110 V
Secondary voltage: 7.1 V - 28.6 V
Primary current: 104 mA - 833 mA
Characteristics:1.Vacuum encapsulated,100℃/six hours high temperature aging,service life 20 years ,high dielectric strength. 2.High quality silicon steel sheet,Low temperature rise,High efficiency. 3.PBT project plastic, environmental ...
YHDC Dechang Electric
Primary current: 160 A
... suppressor built in. Application: used for the current measuring, monitoring and protecting of AC motor, lighting equipment and air compressor.
YHDC Dechang Electric
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining