- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Flange flow meter >
- ENDRESS HAUSER
ENDRESS HAUSER flange flow meters
Process temperature: -450 °F - 450 °F
... Turbine Flow Meter made up with 316 stainless steel material and is used for transferring and flowing applications. This device is equipped with a blade rotor and flanges that is also ...
Hoffer Flow Controls
Process temperature: -40 °C - 180 °C
Process pressure: 1,000,000, 4,000,000, 1,600,000 Pa
LD electromagnetic flow meter is a kind of electromagnetic measuring flow instrument, used to measure all kinds of the volume flow of conductive liquid. This product ...
Process temperature: 0 °C - 150 °C
Process pressure: 0.2 bar - 300 bar
A turbine flowmeter operating on the Pelton wheel principle for low flowrate applications on low viscosity fluids. Conventional axial flow turbine meters become increasingly difficult ...
Roxspur Measurement & Control
Volumetric flow rate: 0 l/h - 500 l/h
Process temperature: -40 °C - 85 °C
Process pressure: 25 bar
... Measuring accuracy - В±1% Temperature range,В°C - -40 – +85 Maximum flow rate in l/h - 500 Output interface - pulses, RS232, RS485, K-Line, CAN Seal rating - IP 67 Flow meter ...
Mechatronics
Mass flow rate: 7 kg/h - 4,000 kg/h
This high-speed exhaust flowmeter samples the four differential pressure transducers at up to 2500 Hz, accurately capturing every forward and reverse flow pulsation from idle to maximum flow ...
Volumetric flow rate: 0.5 l/min - 1,200 l/min
Process temperature: -40 °C - 350 °C
Process pressure: 0 bar - 150 bar
... or customised for OEM flow meter applications: Metri IC-LPM Paddlewheel Flow Meters are manufactured and supplied with either threaded or flanged ...
Metri Measurements
Volumetric flow rate: 0.3 m³/s - 10 m³/s
Process temperature: -20 °C - 60 °C
Process pressure: 600,000, 1,600,000, 1,000,000 Pa
1.Separated type magnetic flow meter 2.Color customization 3.GPRS intelligent 4.irrigation water、feed water、well water、cooling water 5.Meet your requirements GMF100 intelligent electromagnetic ...
Xi'an Gavin Electronic Technology Co. Ltd.
Process temperature: -50 °C - 150 °C
Process pressure: 0 bar - 40 bar
... velocity in the pipe line, therefore the flow measurement is volumetric. The FLEMCO flow meters are backed by international standards covering flow calculation, manufacturing ...
EMCO Controls A/S
Process temperature: -20 °C - 60 °C
Process pressure: 0 MPa - 26 MPa
Repeatibility: 0.1 %
... conditions into account. It has effectively solved the influence on the metering precision caused by flow distortions( such as turbulent flow, swirl flow, pulsing flow ...
Jiangsu Flowna Intelligent Technology Co. Ltd
Process temperature: -20 °C - 80 °C
Process pressure: 1.6 MPa
Precision: 1.5 %
Insertion type electromagnetic flow meter is a type of electromagnetic flow meter has been used throughout industries for more than 50years. Insertion type electromagnetic ...
Q&T Instruments
Process temperature: -40 °C - 350 °C
Process pressure: -1 bar - 63 bar
Precision: 1, 0.75 %
... manufacturers. Find vortex flow meter firms that can design, construct, and produce vortex flow meters according to your needs. Then, using our simple request for quote ...
COMATE
Volumetric flow rate: 0.1 m³/h - 350 m³/h
... Electromagnetic Flow Meter Electronic Part consists of head type Flow Indicator which contains Microprocessor Controller chip mounted on the electronic circuit. It has ...
Process Control Devices
The electronic microprocessor mod. F 130 are easily matched to the flow meter series KDN and allow the aggregation of totalisation and predetermination of all fluids up to 40,000 cps. They can be powered ...
Process pressure: 10, 16, 40 bar
Introduction The FLODEM electromagnetic flow meter are based on decades of practical experiences. They are highly reliable, easy to operate and very suitable for harsh conditions. Features: - Easy ...
SMAAT TECHNIQUES SAS
Process temperature: -20 °C - 100 °C
Process pressure: 0 bar - 40 bar
Transit time type ultrasonic flow meter. Available in kit form or flanged pipe section UN PN 10 or 16. Available in diameters from 50mm to 3000mm. LCD. Power supply 110 - 220VAC - 24VDC. ...
MADDALENA SPA
Volumetric flow rate: 10 l/min - 600 l/min
Process pressure: 6 bar
The flange flow meter is equipped with four stainless steel poles on four sides and uses flange adaptor. This flow meter is robust, ...
Volumetric flow rate: 0.6 m³/h - 70,000 m³/h
Process temperature: 80, 180, 150, 100 °C
Precision: 0.2 %
Electromagnetic flowmeter consisting of a sensor and a transmitter. The flowmeter is used to measure volumetric flowrate for conductive liquids and pulps. Several output signals are available. ...
Volumetric flow rate: 20 l/min - 120 l/min
Process pressure: 0 bar - 10 bar
... emitter. These products can function by gravity due to a reduction in flow resistance. The available range is 20 to 120l/min and the precision after calibration is within 1% of the flow range. Maximum ...
numak srl
Volumetric flow rate: 1.6 m³/h - 1,600 m³/h
Process pressure: 0 bar - 4 bar
Turbine wheel meters for measuring gas flow on gas consumption equipment, for gas burner adjustment, for gas and air. Features & Benefits: DM: mechanical index Connection: thread or installation ...
Process temperature: -20 °C - 80 °C
... station. FLYGT FLOW METERS The MagFlux electromagnetic flow meters combine high accuracy, stability and low maintenance to deliver linear readings over a large ...
Volumetric flow rate: 40 m³/h - 313 m³/h
Process temperature: 0 °C - 50 °C
Process pressure: 16, 10 bar
STANDARDS OF MANUFACTURE EN 1092-2 DRILLING FLANGES MATERIALS BODY CAST IRON EN 1561 (OPT. EN GJS-400-15 EN 1563) CORROSION PROTECTION COATED INSIDE-OUTSIDE FIG.650 (FBE) EPOXY 300 MICRONS RAL 5005 FIG.650IRR ...
Process temperature: -200 °C - 400 °C
Process pressure: 0 bar - 20 bar
Precision: 1, 5, 0.75, 2, 5.7 %
... measuring unit enables mass flow calculation even for superheated steam at fluctuating pressures - all in one device. Optional for EF200F-C and EF200R-C. Integrated flow computer calculates mass ...
Process temperature: -40 °C - 80 °C
Process pressure: 21 bar
... wastewater applications. U0-D0 installation: extreme flexibility on the flowmeter position Measure of extremely low flow rates, even in problematic applications and “night flows” ...
Precision: 1 %
The Verabar® provides the most accurate, reliable technology for measuring gas, liquid and steam as well as the lowest operating and installation costs. How it Works When a fluid impacts the sensor, it creates a high-pressure zone ...
Process temperature: -10 °C - 60 °C
5. The product function introduction 5.1 Basic Function ■ Flow Rate :0.1 --- 15m/s,current speed resolution:0.5mm/s ■ AC high frequency switching power,range of voltage:185VAC --- 250VAC ■ DC24V switching power,range ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining