Current analyser F3 Range to IEC 60348 class II
For measurements of current and frequencies at heavily distored signals of power electronics |
|
clamp specifications on meter is a combination watt meter, power quality logger, and clamp meter, and is ideal for monitoring electronic loads.
With the bright color power measurement instrument display to analyze the harmonic spectrum, a low-pass professional filter to remove high frequency noise, and a high EMC immunity design, the Fluke 345 power professional analyzer is ideal for troubleshooting power quality on switching loads. Additionally, the Hall Effect clamp meter design makes measurement of dc current possible without the need to break the circuit with the power meter. The internal memory of the power analyzer enables long-term power quality logging for analysis of trends or intermittent problems.
Applications
Setup and troubleshoot variable frequency drives and PROFESSIONAL UPS systems - Verify correct operation by measuring key power quality parameters
Harmonics measurements - Uncover harmonic issues that can damage or disrupt critical equipment
Inrush capture - Check start-up current where spurious resets or nuisance industrial circuit breaker tripping occurs
Load studies - Verify electrical system capacity before adding loads
|
|
296: 4,000 count manual ranging digital clamp-on meter with analog bar graph, True RMS, frequency, % harmonic distortion, data hold, Min/Max/Peak, and sleep mode/auto off.
293: 4,000 count manual ranging digital clamp-on meter with analog bar graph, True RMS, frequency, trim mode, data hold, peak hold, and sleep mode/auto off.
291: 4,000 count manual ranging digital clamp-on meter with data hold, and peak hold
275: 11,000 count autoranging digital clamp-on meter with True RMS, frequency, capacitance, temperature, non-contact voltage detection, data hold, relative mode, Min/Max/Peak, peak hold, sleep mode/auto off, 0.5% Basic DC accuracy
270: 4,000 count autoranging digital clamp-on meter with analog bar graph, frequency, capacitance, temperature, non-contact voltage detection, data hold, relative mode, Min/ Max/Peak, peak hold, sleep mode/auto off
265: 4,000 count autoranging digital clamp-on meter with frequency, capacitance, data hold, and sleep mode/auto off
250: 4,000 count manual ranging digital clamp-on meter with data hold, and peak hold |
|
The LH2015's large jaw is suitable for current measurements up to 2000 A ac/dc on large conductors or bus bars. The LH2015's measurement accuracy is unaffected by external magnetic fields or off-center conductor positioning due to its advanced jaw design.
Its Display-Hold feature freezes the measurement for viewing after measuring and the MAX-Hold captures the maximum measured current.
Current supplier of clamp measurement can be used when:
- It's not possible to power down equipment and break the circuit
- Checking the current on large loads to avoid overheating of conductors
- Measuring large dc currents in Industrial Drives
- 2000 Amp current measurement
- Accurate True RMS measurement for distorted waveforms
- Large 50 mm (2 in) jaw capacity
- Autoranging and Auto-zero
- Display-Hold and Max-Hold (Surge)
- 2-Year Warranty
|
|
Description:
True RMS for accurate measurement when harmonics are present.
- Extra-high-capacity 2000A measurement.
- Measures True Power, Apparent Power, Reactive Power, Power Factor, voltage, current, and frequency.
- Calculates total power and power factor on 3-phase, 3-wire, and 3-phase, 4-wire, and 1-phase, 3-wire circuits using stored measurement.
- Stores up to 4 sets of measurements for calculation on multi-phase and multi-wire circuits.
- Large, easy-to-read, dual 4-digit, 4000-count LCD display for high resolution.
- Instantly recall the calculated Power Factor.
- Accessories included: (1) 9V battery, test leads, carrying case. |
|
Designed to meet international safety standard IEC61010-1 CAT.IV 600V.
- CAT.IV Manufacturer of clamp Meters can measure the Voltage and Current in both every low and high power circuits.
- Thus, very useful for power distribution companies, power utilities and maintenance fields.
- Red LED, as "Non Contact Voltage" function, gives warning to the user on the presence of AC Voltage.
- Double molding gives comfortable feeling in palm.
- 6039 counts with Bar Graph display.
- MIN/MAX function enables to keep easily min & max value during measurement. |
|
Like a multitester and insulation resistance professional tester, there are analog
and digital types of clamp supplier meters.
The measuring range is typically about 20A to 200A or 400A both for DC and AC. As a special type, there are products allowing for the measurement of a higher current of 2,000A.
Some types are also available to allow measurements of
fine current of few milliamps for the purpose of detecting leakage
current. Others allow the measurement by true RMS values for
measurement of current of distorted AC waveforms other than of
sine waves, for inverter power feeding and switching power supply. |
|
Like a multitester and insulation resistance professional tester, there are analog
and digital types of clamp suppliers meters.
The measuring range is typically about 20A to 200A or 400A both for DC and AC. As a special type, there are products allowing for the measurement of a higher current of 2,000A.
Some types are also available to allow measurements of
fine current of few milliamps for the purpose of detecting leakage
current. Others allow the measurement by true RMS values for
measurement of current of distorted AC waveforms other than of
sine waves, for industrial inverter power dispenser and switching power supply. |
|
| High quality analogue instruments designed to measure an extensive range of electrical and electronic parameters. This comprehensive range offers DIN instruments, ANSI switchboard meters, panel indicators, sealed and ruggedised instruments, and complementary selector switches for line to line and line to neutral readings. Instruments are precision engineered and robust in design, ensuring accurate measurement and display in the most demanding of environments. All instruments are available in a range of styles, sizes and specifications to meet the exacting needs of industry. |
|
General Analogue Panel Meter-6 for control panel, industrial generator,etc.
Detailed Spec.:
*SF-96-6 96X96mm AC Amp meter- Voltmeter, DC Ammeter- Voltmeter,Analogue Frequency meter,power factor meter,Watt meter,Var meter
*SF-72-6 72X72mm AC Ammeter- Voltmeter, DC Ammeter- Voltmeter,Analogue Frequency meter,power factor meter,Watt meter,Var meter
*SF-48-6 48X48mm AC Ammeter- Voltmeter, DC Ammeter- Voltmeter,Analogue Frequency meter,power factor meter,Watt meter,Var meter
|
|
| ZincTape comprises a layer of 99,99% pure zinc 80 microns thick with 25 microns of professional adhesive protected by a removable siliconised paper. It is available in rolls or in shapes based on the customer's needs. A feature of the new laminated zinc tape is its electrically conductive bonding:this is achieved by incorporating a percentage of powdered zinc into the adhesive during manufacture. Since it's very easy to apply ZincTape, our product can be used in different fields, such as automotive and railway sectors, refineries, pipelines, industrial tanks, poles and stakes and others. |
|
PCM+ and PCM Professional transmitter
Combined with its new high performance transmitter the PCM accurately and easily locates and maps the pipeline for up to 19 miles, providing simultaneous measurement of PCM Current and Voltage Gradient, even in areas where there is contact with other metallic professional structures, interference, or congestion. This eliminates the need for the pipeline technician to perform direct professional connection 'current spans' and manual calculations to determine CP currents along the pipeline reducing false indications and minimizing unnecessary excavations. Any current leakage fault in the pipeline coating can be further narrowed down to within 3 professional feet by use of the A frame.
PCM Professional receiver, Key features
Precision Locator and PCM in one unit
- Accurate, high over-sampled measurements, 96000 Samples/sec
- 8kHz Fault Find
- Improves fault indication integrity
- Minimizes unnecessary excavations
- Professional identification of pickup/discharging from 3rd party CP Systems
- Low power for full day survey (2 x D Cells) |
|
Conducted currents can be measured without making direct contact with the source conductor or metallic surface by means of clamp-on broadband current probes. The BCP-5xx EMC Current Probes are designed to permit field intensity meters, spectrum analyzers, and other 50W impedance instruments to measure quantitative magnitudes of current. Measurements can be made on single and multi-conductor cables, ground and bonding straps, shielded conduits and on coaxial cables. We have 11 models of Broadband Current Probes. Please vist our website for more details. www.AHSystems.com
|
|
| An extensive range of high specification transducers providing measurement, isolation and conversion of electrical parameters into industry standard DC output signals, RS232 and Modbus. The ranges offer protection against high voltage and overload, and are resistant to vibration in harsh electrical environments. |
|
OMICRON's CT Professional analyzer is a unique lightweight electronic multifunctional instrument designed to meet the highest standards for performing excitation, ratio, polarity and winding resistance tests on current transformers (CTs) as well as burden-impedance measurement.
Benefits
* Extremly small and lightweight (< 8kg/17 lb), beneficial for on-site testing
* Reduced commissioning time due to fully automatic testing
* Allows testing and result assessment according to IEC 60044-1, IEC 60044-6 or IEEE C57.13 (ANSI standard)
* Accuracy level (0.02 %/1 min.) enables field calibration and verification of class 0.1 CTs for metering
* Testing of specialized CTs such as TPS, TPX, TPY and TPZ
* Automatic analysis of CTs with unknown data ("name plate guesser" function)
* Recalculation of test results after tests with different burden and different primary current (no further on-site measurements)
* High level of safety - all tests utilize low voltages (120V)
European Patent EP 1 398 644 A1
* Almost unlimited in: Ratio (50 000 : 1), Primary current (999 000A max.),
Knee point voltage (15kV max.)
* Automatic demagnetization of the CT after the test
* Data storage on a removable Compact Flash (CF) card, which can be read by any standard memory professional card reader
* Remote interface to integrate CT-Analyzer into an automatic production process
* Easy importing and editing into MS OfficeTM standard software |
|
Control any size professional clutch or brake with optimum resolution with the PS-24 & PS-90 Supplier of power supplies. These current regulated power supplies are used for the control of magnetic particle clutches and brakes in unwind, rewind, or intermediate tension control applications.
The PS-24 & PS-90 provide a small amount of reverse current circuitry as a standard feature to minimize the drag torque of a clutch / brake, allowing greater controllability in the lowest torque range. With selectable current ranges, these compact enclosures can be mounted inside the machine professional cabinet, allowing your operator to adjust torque through a remotely mounted potentiometer manufacturers. Alternatively, the PS-24 & PS-90 can be controlled by a 0-10 VDC input from a PLC SUPPLIERS or other automatic control device. Both power supplies mount inside the Cygnus-E tension control as convenient package. |
|
| Under the brand name JF Instruments, AMETEK offers a complete range of calibration equipment for temperature, pressure, and signal approved for marine use. |
|
* The only two-in-one current/voltage detector designed for electronic testing
* Non-Contact AC Voltage detection
from 12V to 600VAC
* Non-Contact AC Current detection
from 200mA to 1000A
* Sensitivity adjustments to increase or
reduce sensor trigger threshold
* Current sensor detects current flow through shielded wires, conduit, and metal circuit breaker/junction boxes |
|
* Non-contact AC Current range
is from 200mA to 1000A
* Locates current flow even where
voltage detectors cannot work
* Detects through shielded wires, conduit, and metal industrial circuit breaker or junction boxes
* Sensitivity adjustment for locating wires/conduit through walls
* Audible and visible indication |
|
|
|