Actuating solenoid with built-in electronic timer. Two potentiometers
and two slide switches in the terminal box allow flexible adjustment
of pulse and interval duration. When the power is switched on, there
is a delay of about 1.5s before the valve is opened for a preset pulse
duration.
This is followed by a break (Pause). The durations involved are
generated by a microcontroller.
The power supply may be interrupted to carry out an operating test
without waiting for the break. The (N) terminal can be used to
operate the built-in solenoid independently of the cycle set, or to
operate an external "reference solenoid" in parallel with the internal
coil.
The 110/120V version's solenoid coil is operated by means of an
integral bridge rectifier. In this case external solenoids can only be
supplied with power using an additional rectifier.
Dimensions (mm) Dia.14.5 x H34.1
Type 2way-NC
Orifice Diameter (mm) 1.2
Port Connection Barb Type
Inlet Pressure (kPa) 0 - 80
Outlet Pressure (kPa) 0 - 10
Fluid Temp. Range 0 - 40
Voltage (V) 12DC
Power Consumption (W) 1
Operating Duration Continuous Duty
Coil Temperature Increase 50
Insulation Class E
Body Material U-Polymer
Seal Material FPM