Voltage: 230, 400 V
Primary current: 100,000, 20,000, 3,000, 12,500, 25,000 A
... The 7P Series consists of Type 1 + 2, Type 1, Type 2 and Type 3 surge arresters. These devices include the following ...
Voltage: 60 V - 600 V
... Surge protection devices (SPDs) provide equipment protection from transient overvoltage events lasting micro-seconds. By limiting the overvoltage to the equipment during these events, costly damage and downtime can be mitigated. The surge ...
Littelfuse
Voltage: 48 V
Primary current: 13 A
... MHz AISG return loss - 18 dB AISG insertion loss - 0. 1 dB Residual pulse energy (typ.) - 250 µJ (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs) Surge current handling capability ...
Voltage: 2, 6 kV
Primary current: 26 A
... caused by lightning strikes, electrostatic discharges or power grid switching operations, and are extremely hazardous. Such surges can cause electrical systems to fail, destroy electrical and electronic equipment, or even set entire buildings ...
Siemens Low-voltage – Power distribution
Voltage: 0 V - 3,000 V
... The 3EB2 and 3EB3 silicone-housed surge arresters were developed specifically for overvoltage protection in DC systems in accordance with the VDV A 1-A2 application. The 3EB3 has a DC-C classification ...
type 1 surge arresterDB M MOD series
Voltage: 255, 150, 320 V
Primary current: 35,000, 50,000, 25,000 A
... High discharge capacity due to powerful creepage discharge spark gap Maximum system availability due to RADAX Flow follow current limitation With module release button for replacing protection modules without tools Operating state / fault indication ...
DEHN + SÖHNE
type 1 surge arresterSurge-Trap® STMT1 series
Primary current: 20,000, 25,000, 40,000, 50,000, 12,500 A
... STM T 1 50 is the most robust series of single pole Type 1/Class I lightning current arresters, able to discharge energy (current) from a direct lightning strike (10/350µs) on an external ...
Mersen - Electrical Power
Voltage: 250 V - 850,000 V
Primary current: 50 mA - 260 mA
... Current Limiters (ECLs) that guard against lightning, power induction, power cross, Earth Potential Rise (EPR), and other energy surges. The Bourns® TBU® HSP, a silicon-based, solid-state, resettable device is an effective barrier ...
Voltage: 280 V
Primary current: 50,000 A
... Combination arrestor set, lightning and surge arrestor Type 1+2 to DIN EN 61643-11 (B+C to VDE 0675 part 6). • For lightning protection equipotential bonding to VDE ...
OBO Bettermann
Voltage: 120 V
Primary current: 20,000 A
... Hybrid MOV-GSG Technology UL1449 Type 1 LISTED 50kA Surge Current Rating per mode Extended life with no leakage current Visual LED fault indicator and audible alarm NEMA 6 (exceeds NEMA 4X or 4) ...
CITEL
Voltage: 150 V
Primary current: 5,000 A
... 61643-21 compliance UL497A DLU2 surge protectors are designed to protect, against surge voltages due to lightning, terminals equipment connected to industrial buses, telecom lines or datalines. These ...
CITEL
Voltage: 5 V
Primary current: 1,000 mA
... - CAT5 or CAT6S networks surge protector - 10/100/1000BaseT compatible - RJ45 connector - Shielded enclosure - Bi-directional The MJ8-CAT surge protector is designed to protect ...
CITEL
Voltage: 440 V
Primary current: 12,500 A
... The Surge Protective Device (or SPD: generic name for any device that protects against voltage surges) is a recognized and effective solution to the overvoltage problem for any of power or telecom, data, or signal networks. ...
Indelec
Voltage: 0 kV - 1.3 kV
Primary current: 0 A - 25,000 A
... The Surge Protective Device (or SPD: generic name for any device that protects against voltage surges) is a recognized and effective solution to the overvoltage problem for any of power or telecom, data, or signal networks. ...
Indelec
Voltage: 440 V
Primary current: 30,000 A
... The Surge Protective Device (or SPD: generic name for any device that protects against voltage surges) is a recognized and effective solution to the overvoltage problem for any of power or telecom, data, or signal networks. ...
Indelec
Voltage: 0 V - 275 V
Primary current: 0 A - 20,000 A
... Distribution Boards Housing: Pluggable Design Protective Elements: High Energy MOV IEC/EN Category: Class I+ll / Type 1+2 ...
Voltage: 120 V - 440 V
Primary current: 25,000, 100,000 A
... systems. Can be used in TN-S systems The surge arrester meets the requirements of IEC61643-11 The unit is designed to be used between Zone O and Zone 1 (according to IEC62305-4 definition of Lightning ...
Britec Electric Co., Ltd
Voltage: 275, 320, 150 V
Primary current: 12,500, 25,000 A
... GB18802. 1 IEC61643-11 Fault indication via red mark in the inspection window. Application: To prevent power supply equipment from being damaged by surge and lightning. Use on buildings in applications where there ...
Britec Electric Co., Ltd
Voltage: 120 V - 440 V
Primary current: 25,000 A
... from violent vibration. Ensure that the maximum continuous working voltage of the surge protector meets the actual requirements. The wire connecting the surge protector should be as ...
Britec Electric Co., Ltd
... coaxial protector configured with BNC female connectors for dc to 30 MHz signals Specifications for PolyPhaser IS-75BB/18 Mount Type Flange Frequency Range dc to 30 MHz Protected Side Connector BNC Female ...
PolyPhaser | Transtector
Voltage: 400 V
Primary current: 25,000 A
... • Tested and certified as a protector Type 1 and 2 according to the standard EN IEC 61643-11. • Suitable for Categories I, II, III, IV according to ITC-BT-23. • Double connection in order to facilitate wiring (limited ...
Aplicaciones Tecnológicas, S.A.
Primary current: 25,000 A
... as electrical equipment the SURGYS G140-F surge arrester is specially designed. It is useful against overvoltages due to industrial operation as well as over voltages due to lightning. This kind of surge ...
SOCOMEC
Voltage: 320 V
... According to DINVDE0675, Part6 standard, this lightning protection device is a class B power supply lightning protection device. Its performance conforms to the IEC61643- 1(GB18802. 1-2011) ...
... ETITEC Went surge arrestor is perfect for indoor applications. This protection corresponds to the IEC category I, II. The protection is made on the main distribution box, which stands as the first level of protection against surges ...
... The ZoneDefender Curve range surge suppressor is specifically designed for applications that require a Type 1 or Type 2 SPD. Type 1 ...
... Type 1 Surge Protector Device (SPD) We are a trusted surge protector devices manufacturer in China specializing in manufacturing high-quality surge ...
LSP
... Features Operates between 0-6GHz Fitted with bulkhead type panel mounting N surge suppressor (m-f) Light duty surge protector Benefits ...
Voltage: 650, 800, 1,100, 1,500 V
Primary current: 20,000 A
... Strikesorb 35 surge protective device is designed specifically for DC applications operating at voltage up to 1500 V and is compliant with the UL 1449 4th edition and EN 50539-11 standards. - Category IEC / UL: Type ...
Raycap
Voltage: 3 kV - 36 kV
Primary current: 5,000 A
... Products are strictly in accordance with GB, IEC, IEEE and other standards Through Kema, CEPRI, XIHARI and other test reports It has excellent nonlinear volt ampere characteristics. Simple structure, no gap, small size, light weight. Fast ...
jinniu electric
Voltage: 230 V
Primary current: 50,000 A
... CSH is the most robust range of single pole Type 1/Class I lightning current arresters, able to discharge energy (current) from a direct lightning strike (10/350) on an external lightning ...
Cirprotec
Voltage: 1,500, 1,800 V
Primary current: 5,000, 20,000, 40,000 A
... -DC surge protector specially used for photovoltaic system 1500Vdc. -The core parts are metal oxide vristor components with high discharge capacity. -With Reliable control thanks to Thermo Dynamic Control disconnector. -Without ...
FATECH ELECTRONIC (FOSHAN) CO., LTD
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group