Tripping current: 208 mA
Trigger voltage: 24 V
For the connection of safety light curtains / safety light grids with OSSD Safety relay with integrated muting function Safety category type 4 to IEC 61496 Integrated signal and feedback contacts
... module models have a variety of safety inputs, solid-state safety outputs and safety relay outputs • Innovative live display feature and diagnostics allow for active monitoring of I/O on a PC and assist ...
... Supports a wide range of safety devices, eliminating the need to buy and stock safety relay modules dedicated to specific safety devices • Two safety six amp relay outputs each with three N.O. sets ...
Tripping current: 0 mA - 220 mA
... start/restart Start/restart interlock (RES) Static contactor monitoring (EDM) Stop function according to category Stop 0 Restart - Automatic Manual SIL - 3, IEC 61508 SILCL - 3, IEC/EN ...
Leuze electronic GmbH + Co. KG
Tripping current: 6 A
Trigger voltage: 24 V
unctions - Cross circuit monitoring One- or two-channel operation Start/restart interlock (RES) Time-delayed shutdown (STOP1) Restart - Automatic Manual SIL - 3, IEC 61508 SILCL - 3, IEC/EN ...
Leuze electronic GmbH + Co. KG
Tripping current: 0.5, 2 A
Trigger voltage: 24, 230 V
Application - Signal conversion of electronic safety outputs on potential-free relay contacts Restart - Automatic SIL - 3, IEC 61508 SILCL - 3, IEC/EN 62061 Performance Level ...
Leuze electronic GmbH + Co. KG
Trigger voltage: 24, 120 V
Our Bulletin 700S-CF Safety Control Relays provide mechanically or mirror contact performance, which are required in feedback circuits for safety applications. Bifurcated contacts are ideal for low energy feedback safety ...
Allen-Bradley
Tripping current: 3, 4, 2 A
Trigger voltage: 230, 24 V
... CM liquid level monitoring relay range. It operates with a rated control supply voltage of 220-240 V AC and has a 1 n/o output contact. It monitors liquid levels of conductive fluids and protects tanks ...
ABB
... Level (SIL) CL claim limit 3 of IEC 62061? Do you need a safety relay that will cover the basic functions? Is it important to you to save time through simple installation and maintenance? In ...
Trigger voltage: 12 V - 24 V
... PRO relay monitors undervoltage to protect motors and equipment from being damaged by blowouts. The multi timer can sense a maximum voltage of 24 V DC and has a single pole double throw (SPDT) contact ...
Tripping current: 120, 200 A
Trigger voltage: 230, 240 V
... latching relays custom designed to provide the highest electrical performance in a compact package. The compact relays utilize innovative technology for accurate switching with low contact resistance ...
The MiCOM Alstom P24x relays provide advanced control, protection and monitoring. They offer comprehensive protection for induction and synchronous machines due to their versatility. The MiCOM Alstom ...
Alstom Grid
Tripping current: 0.03 A - 5 A
Electronic industrial earth leakage protection relay, compatible with the WGC series protection transformers. Type A ultraimmunised relay with high frequency current filtering and high immunity. True ...
... current intensity monitoring relay (IEC 62020), compatible with the WGC-TB series protection transformers. The RGU-10B is the most complete system of the range that monitors and controls ...
... Level (SIL CL) 3 to IEC/EN 62061 -- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511 • According to EN 50156-1 for furnaces • 2-channel operation • Forcibly guided ...
DOLD
The multifunctional safety module UG 6970 from the SAFEMASTER C family serves the protection of staff and machinery by releasing and interrupting safety circuits. Up to two independent safety functions which are selected in a simple way ...
DOLD
The multifunctional safety timer UG 6960 from the SAFEMASTER C family serves the protection of staff and machinery by releasing and interrupting safety circuits. The UG 6960 combines safety time functions and safety functions ...
DOLD
Trigger voltage: 24 V - 230 V
Modular isolation monitoring devices Sentinel Isolation monitoring sentinel for LV networks up to 500 Vac; 2 modules; 110–230–400 Vac power supply.
... insulation - IEC61010-1 CAT III,300V connections - withdrawable terminals setfestinguishing thermoplastic material - UL94-V0 protection for housing - IP50 protection for front - IP52 protection for terminals - IP20 according ...
... wiring. XAC032 Direct maximum current relay 5÷720A, 32x10mm XAC040 Direct maximum current relay 40÷1200A, 40x10 XAT061 Direct maximum current relay 60÷1800A, 61x31 Ø51 XAT101 Direct ...
Trigger voltage: 24, 230 V
This is a voltage monitoring relay module that is capable of measuring 1-phase networks. Our E1UM230V01 lets you select a suitable voltage range of 24V AC, 24V DC or 230V AC in one device. The settings ...
Trigger voltage: 690 V
... feedback of the power and phase condition while two integrated relay outputs (DPDT configuration) trigger alarms to your PLC or trigger actions. Our TELE technology allows to power our monitoring relay ...
Trigger voltage: 24 V
MZERO - A compact and configurable safety controller MZERO is a configurable safety hub able to manage all safety functions of a machinery or a plant. Configurable, allows cost reductions and minimal wiring. MZERO can manage ...
Tripping current: 5 A
... safety interfaces for emergency stop buttons and safety switches Safety relays for monitoring emergency stop buttons, safety switches. With 3 N.O. + 1 N.C. guided-contact safety relays. The ...
Tripping current: 2 A
... contact safety relays Muting Time-out selectable Integrated Override with 2 operating modes selectable Muting Enable input Other integrated functions Start/Restart interlock EDM Feedback input for extra external ...
Tripping current: 4, 6 A
Trigger voltage: 250, 240, 24 V
Supports emergency stop switch, safety door lock, PNP type safety light curtain, and photoelectric input Precise control, can be adapted to different safety functions through the function DIP switch. Dual-channel, single-channel-dual-channel, ...
Bytorent Technology Co., Ltd.
Tripping current: 4, 6 A
Trigger voltage: 250, 240, 24 V
Supports emergency stop switch, safety door lock, and passive switch inputs Precise control, can be adapted to different safety functions through the function DIP switch. Dual-channel, single-channel-dual-channel, single-channel-single-channel ...
Bytorent Technology Co., Ltd.
Tripping current: 4, 6 A
Trigger voltage: 240, 250, 24 V
PNP/NPN type safety light curtain, photoelectric, active switch signal input Precise control, can be adapted to different safety functions through the function DIP switch. Dual-channel, single-channel-dual-channel, single-channel-single-channel ...
Bytorent Technology Co., Ltd.
Tripping current: 5 A
Trigger voltage: 30, 230 V
... controlling module and detecting modules (only B-type detecting modules available now). The device is designed in accordance with IEC/EN 60947-2, Appendix M. - Space saving One controlling module at 36mm width can ...
Trigger voltage: 80, 150, 350, 600 V
Function Features -Controls its own supply voltage(True RMS measurement). -LCD display. – Measuring frequency range:45Hz-65Hz. – Voltage measurement accuracy<1%. – 2-MODULE,DIN rail mounting. • Control for connection of moving equipment(site ...
Zhejiang Geya Electrical Co., Ltd
Trigger voltage: 24, 115, 230, 400 V
... the hysteresis which is adjustable on the front, the relay de-energises. With inverted relay function the internal relay work the opposite way. The Voltage relay has ...
Brodersen Controls
Tripping current: 4 mA - 2,000 mA
Trigger voltage: 24, 115, 230 V
... current relay is a relay for monitoring off load in applications with a relative low AC- and DC current up to 2A AC/DC. The relay can with advantages be used as an alarm ...
Brodersen Controls
Tripping current: 10 mA - 5,000 mA
Trigger voltage: 24, 115, 230, 400 V
... the hysteresis which is adjustable on the front, the relay de-energises. With inverted relay function the internal relay work the opposite way. The Current Relay has ...
Brodersen Controls
... situations: commercial buildings, industry, offices, private homes, public establishments, and many more. Recognised by ISO/IEC 14543-3-x as international standard for the system technique of buildings and homes, Konnex, ...
Trigger voltage: 24 V - 240 V
... safety relays offer outstanding simplicity, flexibility and cost-effectiveness. Their modular design simplifies the planning, commissioning and expansion of plants. Simple safety functions, such as EMERGENCY STOP and ...
Siemens Safety Integrated
These grid automation relays are designed for remote control and monitoring, protection, fault indication, power quality analyzing and automation in medium-voltage secondary distribution systems. With ...
Naturally your production must be safe. But above all, your facility must be continuously operational. Any interruption can result in significant costs. With the HIMax safety solution you comply with the most rigorous safety standards, ...
HIMA
Trigger voltage: 24 V - 230 V
Safety relays are intended to reliably monitor the signals from safety devices and switch off quickly in an emergency. Eaton’s ESR5 safety relays provide optimal safety and a high reliability for plant ...
Trigger voltage: 208 V - 600 V
Voltage monitoring realy for three-phase system, without neutral, phase loss and incorrect phase sequence, 208...480VAC 50/60Hz • ype of product: Voltage monitoring relays • Type ...
LOVATO ELECTRIC
Your suggestions for improvement: