TOC is used in a variety of applications from management of waste water treatment plant influent and effluent, to drinking water supply management and monitoring of impurities in process and natural waters. And the range of applications in which this type of on-line technology is used is expected to continue expanding.
In addition, because nitrogen is considered to be one of the factors which contributes to the over-proliferation of organisms in enclosed bodies of water, management of these public water sources and of treatment plant influent and effluent also includes demand for monitoring of nitrogen levels.
|
|
The instrument provides on-line monitoring of active chlorine or total free chlorine in drinking water plants, drinking water distribution networks, and in cooling water.
-Low detection limit for efficient residual chlorine monitoring
-Measuring range of 0 - 5 mg/L of HOCl or free chlorine
-Two analog outputs
-Automatic temperature compensation
|
|
# mmediately signal hardness breakthrough to activate regeneration
# Makes your water softening system more efficient and less costly
# Reliable, simple and accurate- with automated calibration
# Continuous monitoring in "real time"
|
|
Orion 2120XP Calcium Hardness Analyzer
The Thermo Scientific Orion 2120XP calcium hardness analyzer detects calcium as the major component of hardness in real time- providing accurate and reliable results that you can count on. Limiting the costly effects of improper water purification has never been easier.
|
|
|
|
|
|
Modular System
The Hach sc1000 Multi-parameter Universal Controller is a fully modular system consisting of a Display Module and one or more Probe Modules. The Display Module and Probe Module must be ordered separately.
Display Module-The sc1000 Display Module is a full-featured controller with a large color touch-screen display. The intuitive, easy to use interface can be used for any number of parameters. One Display Module controls either a single Probe Module or a number of Probe Modules connected by a digital network. The Display Module is fully portable and can be disconnected and moved anywhere within the network. The Display Module must be ordered separately from the Probe Module.
Probe Module-Each sc1000 Probe Module provides power to the system and can accept up to 8 digital sensors. Probe Modules can be networked together to accommodate many more sensors attached to the same network. Only one Display Module is needed for a networked system. The Display Module must be ordered separately from the Probe Module.
Digital Network-Connect up to 32 participants in an sc1000 network. Network together mulitple Probe Modules to meet almost any application's needs. Participants are defined as anything attached to the network including probes and optional cards but not counting the Display Module or Probe Modules.
|
|
The transmitter is also available to use in combination with the Turbidity Checker / SS Checker.
As well as the turbidity/SS indication, this transmitter can indicate signal output response time, alarm level setting and so on.
You can control the turbidity/SS utilizing its functions fully.
|
|
CHLORINE RESIDUAL ANALYZER
The CRA 3500 Chlorine Residual Analyzer is the first polarographic CRA to offer automatic calibration. Cleverly engineered and using state of the art electronics the CRA 3500 is able to save customers considerable sums of money by auto- calibrating at user defined time intervals.
BENEFITS
- Automatic Calibration
- Low Purchase Cost
- Low Cost of Ownership
- Reduced pH Dependency
- SMS Text Alarms
- Webserver*
- Bluetooth
- 4-20mA and Relay Outputs
- Carbon Dioxide or Acid Buffer if Required
- Can Operate for Three Months without Operator Intervention
|
|
General description:
Free residual chlorine analyzer type M 1032 C is designed for measurement and control in drinking water, waste water treatment and swimming-pools applications.
The unit consists of two electrodes (gold and copper - measurement electrodes) measurement cell with mechanical cleaning and microprocessor controlled unit with graphic display. With clear measured signal control unit evaluates and amplifies cell current and with an automatic temperature compensation we have an accurate measured signal on the output and on the graphical display shown in mg/l.
Control unit is equipped with galvanically separated 4-20 mA signal on the amplifier output.
User can easily communicate with control unit over graphic display and four keys.
|
|
Measuring and control instrument for free chlorine
- Easy and safe operation by plain text menu guidance
- Safety by password function
description
The K 100 (W) CL2 is a sophisticated single-channel instrument for measuring and control free chlorine. Additionaly temperature measurement of the measuring media is possible. The instrument is available in a panel mounted housing (K100 CL2) and in a wall mounted housing (K 100 W CL2).
|
|
* 0 to 5 mg/L range, dual, fully-adjustable set-point alarms
* IP62 enclosure rating, suitable for indoor installation
* Automatic, self-testing diagnostics
* Minimal routine maintenance required
* Colorimetric DPD chemistry - fast, reliable, economical
* Unattended operation up to 30 days
* Manual or automatic feed pump control
|
|
|
|
|
|
|
The field-proven Thermo Scientific SOLA II eliminates labor-intensive laboratory sampling by providing online analysis for continuous quality control of total sulfur content in liquid hydrocarbon and gaseous process streams. Fully-automated sample preparation negates the need to load vials, syringes or sample cups. The system is equipped with an on-board statistical analyzer that verifies the validity of each analysis. Full scale measurement ranges are from 0-5 ppm/wt to 0-9000 ppm/wt with detection limits as low as 0.25 ppm. The SOLA II is an online adaptation of the ASTM Method D5453 “Determination of Total Sulfur in Light Hydrocarbons, Motor Fuels and Oils by Ultraviolet Fluorescence” and the ISO Method 20846 “Petroleum Products – Determination of Sulfur Content of Automotive Fuels – Ultraviolet Fluorescence Method” and regularly demonstrates excellent agreement with total sulfur measurement methods, including ASTM D5453, ISO Method 20846, lead acetate colorimetry, and ASTM D2622. The SOLA II is comprised of a sample injection valve, a carrier gas flow control system, a mixing chamber, a Pyrolyzer, an optional dryer and a pulsed ultraviolet fluorescence (PUVF) detector. The SOLA II has a number of applications, including detection of sulfur to ensure diesel and gasoline are in compliance with clean fuel regulations, catalyst protection by controlling the sulfur level of the hydrocarbon feed into the reactor catalyst, monitoring the sulfur content of the flare gas to ensure compliance with regulatory requirements, and a dual calibration/dual stream model that enables two streams of radically different sulfur concentrations to be measured by a single analyzer.
|
|
|
|
|
|
Sievers 500 RL On-Line
GE Analytical Instruments’ new Sievers 500 RL On-Line TOC Analyzer delivers the accuracy, automation, and confidence needed to transition from laboratory to on-line TOC for enhanced operating efficiencies and science-based risk management. Using the proven Sievers laboratory TOC measurement technology, the Sievers 500 RL provides continuous quality assurance for on-line pharmaceutical water release, cleaning validation, and Process Analytical Technology (PAT) quality initiatives.
The Sievers 500 RL On-Line TOC Analyzer uses no reagents and features the revolutionary four-port Super iOS standards introduction device that fully automates system protocols, and transfers critical standards information directly to the Analyzer for secure data management, significantly reducing costs and risks.
The 500 RL Analyzer shares many productivity and ease-of-use features of other Sievers TOC Analyzers, including 12-month calibration stability, a color touch-screen display, USB port, and minimal maintenance (a few hours per year). With a wide operating range of 0.03 ppb to 2,500 ppb, the 500 RL also measures USP conductivity.
|
|
BioTector - TOC ONLINE ANALYZER
TOC, COD, BOD, TC, TIC, VOC - The oxidation process that totally self-cleans
PRODUCT OVERVIEW
• Self-cleaning technology
• Uptime - Typically 99.7%
• Results < 6.5 minutes
• Multi-range
• Single and multi-stream option
• Nitrate & phosphate analysis modules available
General Information
Designed to withstand corrosive environments, the BioTector TOC Analyzer is housed in an FRP enclosure with dual compartments to keep all electronic components separate from the “wet” or analysis section. The BioTector TOC Analyzer has an in-built microcontroller and is operated through a membrane keypad. An SD Falsh Card allows easy software & configuration updates and may be used to download the 5,000 event archive.
|
|
The AQUAPOD LIGHT detects and analyzes on line nitrates in water starting from a spectroscopic technology of measurement UV
The AQUAPOD LIGHT integrates an analysis UV as well as a detection of fluorescence (in option) making it possible to reach thresholds of sensitivity about the ppm (for the majority of the parameter the µg/L (hydrocarbons)
Easy to install, without reagents nor calibration and maintenance, the AQUAPOD LIGHT ensures you a cost of very low exploitation.
The AQUAPOD LIGHT UV FLUO can accept any type of physico-chemical sensors Modbus RS485, 4 - 20 my...
Moreover, thanks to its exits Modbus, Profibus and Can Open, the AQUAPOD LIGHT can be interfaced quickly towards any system of supervision or communication GPRS or STN
|
|
the AQUAPOD the AQUAPOD LIGHT detects and analyzes a broad range of parameter and pollution of drinking water, natural water, industrial wastes, sea water:
NITRATES
DBO
DCO
COT
MY
UV 254 NM
GENERAL ANOMALIES OF WATER
COLORIMETRY
HYDROCARBONS
URBAN REJECTIONS
COMPLEX INDUSTRIAL PRODUCTS
SPECIFIC PRODUCTS
The AQUAPOD LIGHT integrates an analysis UV as well as a detection of fluorescence (in option) making it possible to reach thresholds of seusibilities about the ppm (for the majority of the parameter to the µg/L (hydrocarbons)
Easy to install, without reagents nor calibration, the AQUAPOD Light 2000 ensures you a cost of very low exploitation.
The AQUAPOD LIGHT UV FLUO can accept any type of physico-chemical sensors Modbus RS485, 4 - 20 my...
Moreover, thanks to its exits Modbus, Profibus and Can Open, the AQUAPOD LIGHT can be interfaced quickly towards any system of supervision or communication GPRS or STN
|
|
The PowerMon Titrometer is a versatile applicable on-line measuring instrument. It guarantees a permanent optimal water quality by the continuous supervision in the chemical industry, water and waste water treatment, in power stations and the paper industry.
Advantages
- fully automatic operation
- easy, comfortable operation
- fast data transfer
- precise results
- self-monitoring system
- minimum operating cost by small reagent consumption
- connection of up to 100 external, physical measuring sensors
- remote maintenance and network ability
- update of the operating software or download of data by USB stick
- graphic user interface with interactive Touch Screen operation
- second measuring point without surcharge
- operation also possible without housing
|
|
These analyzers and sensor assemblies are suitable for measuring fluoride concentration typically found in drinking water applications and are a simple, cost-effective solution for ensuring regulatory compliance in fluoridated drinking water.
Benefits:
- Low price
- Low maintenance
- No chemical additions
|
|
The Analyst provides far greater accuracy and convenience for water testing. Using the latest advances in microprocessor technology, The Analyst provides a direct-reading, user-friendly analysis system for your choice of 90+ water tests. Most test kits use convenient tablet reagents. Compact, rugged and portable, The Analyst is equally reliable in lab, plant, classroom or field.
Important Features
Choose from OVER 90 pre-standardized important tests
Permanent calibrations for 90+ tests are stored in the memory of The Analyst microprocessor. No standard solutions, calibrations, charts, graphs, or calculations are needed. Procedures manual (supplied) contains all 90+ test instructions. Just read the accurate result directly from the liquid crystal display.
For more information, please visite our website
|
|
The TN, or Total Nitrogen, Analyzer is an additional analysis tool available from BioTector Analytical Systems. When the BioTector oxidizes organic carbon compounds (for TOC measurement) it also oxidizes bound (organic and inorganic) nitrogen compounds and ammonium compounds into nitrate (NO3-). This nitrate is present as an aqueous ion in the oxidized sample fluid in the BioTector reactor.
When TOC analysis is complete, the sample fluid is brought from the reactor into a measuring cell. Here the spectrophotometer analyzes the wavelengths applicable to nitrates. The result is displayed as Total Nitrogen (TN). A cleaning fluid is then passed through the measuring cell automatically, which ensures that operator cleaning and maintenance is kept to an absolute minimum.
|
|
BioTector TOC TN TP Analyzer
The TP, or Total Phosphorous, Analyzer is an additional analysis tool available from BioTector Analytical Systems. When the BioTector oxidizes organic carbon compounds for TOC measurement, it also reduces phosphorus compounds (with the exception of poly-phosphates) to orthophosphates (PO4-). This phosphate is present as an ion in the oxidized sample fluid in the BioTector reactor.
|
|
The PowerMon Ionometer is a versatile applicable on-line measuring instrument, which is used for the monitoring of the legally prescribed limit value in the outlet of municipal and industrial purification plants.
Advantages:
-precise results
-connection of up to 100 external,
physical measuring sensors
-fully automatic operation
-easy, comfortable operation
-fast data transfer
-self-monitoring system
-remote maintenance and
network ability
-graphic user interface with interactive
Touch Screen operation
-update of the operating software or
download of data by USB stick
-minimum operating cost by small
reagent consumption
-second measuring point
without surcharge
-operation also possible
without housing
|
|
The Monitor 90 Ecometers are used to measure gaseous inorganic chorine, fluorine or ammonium compounds.
They are ideal for process monitoring and emission control, and comply
to the requirements of the German emission control regulations
(BImSchV) - among the strictest in the world. The high system availability makes the Ecometer an ideal component of automatic control systems for emission control installations.
Advantages:
-Minimal reagent consumption
for low operating costs
-Low maintenance, with selfchecking and automatic recalibration
-Automatic correction for
sample pressure and temperature
-Low sensitivity to interference,
below statutory requirements
-High stability, with low standard deviation and drift
-Industry standard interfaces and outputs
|
|
The PowerMon Kolorimeter is a versatile applicable on-line measuring
instrument. It guarantees a permanent optimal water quality by the
continuous supervision of the legally prescribed limit value for total phosphate and ortho-phosphate in the outlet of municipal and industrial purification plants.
Advantages:
-precise results
-connection of up to 100 external,
-physical measuring sensors
-fully automatic operation
-easy, comfortable operation
-fast data transfer
-self-monitoring system
-remote maintenance and
network ability
-graphic user interface with interactive Touch Screen operation
-update of the operating software or
download of data by USB stick
-minimum operating cost by small reagent consumption
-second measuring point without surcharge
-operation also possible without housing
|
|
The PowerMon Kolorimeter is a versatile applicable on-line measuring
instrument. It guarantees a permanent optimal water quality by the
continuous supervision of the legally prescribed limit value for total phosphate and ortho-phosphate in the outlet of municipal and industrial purification plants.
Advantages:
-precise results
-connection of up to 100 external,
physical measuring sensors
-fully automatic operation
-easy, comfortable operation
-fast data transfer
-self-monitoring system
-remote maintenance and network ability
-graphic user interface with interactive
Touch Screen operation
-update of the operating software or
download of data by USB stick
-minimum operating cost by small
reagent consumption
-second measuring point
without surcharge
-operation also possible
without housing
|
|
MATi stands for Metrohm Automated Titration System.
MATi 1 is a fully automated and PC-controlled water analysis system based on the new 836 Titrando and the new 815 Robotic USB Sample Processor XL. In particular, it contains the new quick aliquoting device 6.9958.007, an overflow buret allowing to quickly and precisely dose after the conductivity measurement 100 mL water sample necessary to do pH measurement, alkalinity determination and finally the water hardness titration.
The MATi 1 has all it takes to perform 59 water determinations fully automatically and includes all necessary accessories and sensors. It is a ready-to-use system that fulfills all your requirements:
Full water analysis
Quick aliquoting device
PC-controlled
High sample capacity
|
|
The Tekran® Series 2600 system allows the analysis of ultra-trace levels of total mercury in liquid samples. It offers unparalleled sensitivity and flexibility for those who require truly sensitive total mercury analysis.
Series 2600 is capable of providing a fully automated implementation of the new US EPA Method 1631. This method is capable of measuring waters with a detection limit of much less than the required < 0.5 ng/L (ppt).
Key Features
- Sensitivity measured in parts per quadrillion. Typical MDL: <0.05 ppt
- Atomic Fluorescence based: Greater sensitivity, selectivity and dynamic range than AA based systems
- Unprecedented modularity and flexibility
- Capable of multiple methods:
Direct reading
Single stage gold preconcentration
Dual stage gold preconcentration
- Works with stannous chloride or sodium borohydride reduction
|
|
|
For automatic determination, monitoring and LC display of the total residual hardness (water hardness) in the water. The parameter to be measured and the appropriate measuring range are determined by indicator selection and by an appropriate user program. Control via alarm horn, stop solenoid valve or similar devices. Connection provided for recorder and central control station for transmission of analysis results (0/4 - 20 mA output signal), power supply 230 V, 50 Hz with EC type certificate according to guideline 97/23/EC.
|
|
Orion 3-Star Plus Benchtop Dissolved Oxygen Meter
- Improved stability algorithm to increase calibration and measurement accuracy
- Average slope and slope of segment printed with measurement
- Ability for ATC temperature calibration
- Increased data log points: 1000
- Ability to turn off data log
- Ability to print or view last 10 calibrations
- New Individual method passwords
- Now with ability to operate an auto-sampler!
- Ability to turn off BOD stirrer
- Solution and membrane temperature printed with measurement
- Solution and membrane temperature displayed
- Ability to calibrate both solution and membrane temperature
- DO slope now on printout
|
|
Thermo Fisher Scientific offers a comprehensive range of Russell pH electrodes and electrochemical sensors. The full range of products includes meters, electrodes and ancillaries for the measurement of pH, ORP, conductivity, dissolved oxygen and specific ions. Water test strips and kits complement the range of products for the potable water and environmental testing markets. Thermo Fisher Scientific is committed to providing the best instrumentation for a wide array of laboratory analyses.
|
|
| ... products without technical information |
| |
|
|