... miniaturization and a wirewound type suitable for power consumption reduction. They thus support signal circuits, power circuits, and large-current power circuits of various electronic ...
Frequency: 60, 50 Hz
Voltage: 208 V - 480 V
Primary current: 20, 320, 40 A
... Hitachi Energy's active harmonic filter PQactiF is the modular, flexible, high-efficiency solution for modern power networks’ problems of ‘pollutants’, like harmonics, low power factor and unbalances. PQactiF ...
Frequency: 50 Hz - 60 Hz
Voltage: 380 V - 480 V
Primary current: 190, 250, 310, 400 A
... The flexible filter for central/decentral harmonic mitigation The VLT® Advanced Active Filter AAF 006 improves system efficiency and increases grid robustness to avoid downtime. It can compensate for individual drives ...
Danfoss VLT Drives
Frequency: 50, 60 Hz
Voltage: 250, 125 V
Primary current: 1 A - 16 A
... • 2-Stages filter • Very high attenuation • broadband • Fuseholder • Thermal circuit breaker • Surge protection Unique Selling Proposition • Slim filter for DIN-rail mounting or chassis mounting • With fuse holder ...
Frequency: 60, 50 Hz
Voltage: 480, 400 V
Primary current: 30 A - 400 A
... filtered for maximum filter effectiveness Power factor correction both inductive and capacitive Phase current balancing, improvement of consumption in neutral (4W model) If higher filtering capabilities ...
Frequency: 50, 60 Hz
Voltage: 3 kV - 35 kV
... active harmonic compensation with cost effective solution • Dynamic reactive power compensation for both inductive and capacitive loads • Continuous variable reactive power output without over-compensation and under-compensation • ...
... demanding applications such as trains and underground transport. They are found in auxiliary and traction converters and in some electrical cabinets. The units are mounted on the roof, under the cabinet and/or inside the converters. For ...
Suppressor modules from Murrelektronik ensure machine availability. The benefits of suppressor technology are enormous and far outweigh the measures linked with its deployment. For a small price, you can prevent malfunctions or faults and save considerable ...
Frequency: 60, 50 Hz
Voltage: 380 V
Primary current: 15 A - 300 A
... the current injection in power supply and distribution system, the realization of function to suppress harmonic and dynamic reactive power compensation. Series product specification model SYICD series ...
Frequency: 50, 60 Hz
Voltage: 208 V - 690 V
Primary current: 50 A - 450 A
... Overview Active Power Filter (APF) is a new type electronic device which is used to prevent dynamic harmonic and compensate reactive power. It can compensate the size-changing and frequency-changing ...
Frequency: 48 Hz - 63 Hz
Voltage: 520, 480 V
Primary current: 250 A - 2,500 A
... High Current EMC Filters Very high attenuation Low leakage current Connection via copper busbars UL approval (up to 1000A) ...
EPA GmbH
Voltage: 150, 250 V
Primary current: 6, 3, 30, 20, 10 A
... This filter is indicated for whichever electronic device that demands a line filter. It is characterized for a very low leakage current. The medium insertion loss of this filter is around ...
DETAS
Frequency: 50 Hz - 60 Hz
Voltage: 220 V - 690 V
Primary current: 100 A
... Active Power Filter (APF) Model Number: APF 3P3W 50A – 200A, APF 3P4W 50A – 200A Nominal Capacity: 50 A – 200A Nominal Voltage: 220VAC, 400VAC, 690VAC Nominal Frequency: 50HZ/60HZ Installation method: Stand, Wall Mount Application ...
Shenzhen Consnant Technology Co., Ltd.
... All ROPEX temperature controllers require a line filter in order to comply with EMC directives and ensure CE conformity. Line filters damp the reaction of the phase control on the line and protect the temperature controller ...
ROPEX Industrie-Elektronik GmbH
Frequency: 50 Hz - 60 Hz
Voltage: 600 V
Primary current: 42 A - 200 A
... emission test for the IEC61000-6-2 and IEC61000-6-4 Standards Markets Automation Machine Tools Solar Power Wind Power ...
ENERDOOR
Frequency: 14 MHz - 55 MHz
... Code SS5 Electrical specifications • Rated voltage : 440 VAC • Power line frequency : 50/60 Hz • Max. leakage current for standard version each line to ground @ 10 A 250VAC 50Hz: 1,0mA @ 20 A 250VAC ...
COMESTERO SISTEMI
... LCL filters, which are particularly popular in the renewable energy industry today, are an efficient and economical way of ensuring and improving the quality of power fed from the energy source to the grid. Their purpose ...
Frequency: 400 Hz
Voltage: 0 V - 250 V
Primary current: 1 A
... is an EMI, EMC, & RFI Power Line Filter from BLA ETECH. Designed for single phase applications it has general purpose filtering performance and good noise suppression. Rated at 1 amp, ...
CD Automation UK Ltd
Frequency: 315 MHz
Voltage: 6 V
... SAW filters are an important component of modern communication systems. This is due to the combination of very good electrical properties with their small dimensions. In addition, SAW filters have more ...
Frequency: 4.9 MHz
... This low pass filter offers a passband from DC to 4,9 MHz with 0,5 dB of insertion losses and a high rejection of 100 dB at 18 MHz. Fitted with BNC connectors, it offers a VSWR of 1.5:1 and a power handling ...
DETI Microwave
Frequency: 3 GHz
... Coaxial Termination is mainly used to absorb the power from RF or microwave system,which could be used as antenna’s fake termination and transmitter ‘s end-user.At the mean time it also be used for multi-ports microwave components such ...
Yantel Corporation
Frequency: 60, 50 Hz
Voltage: 400 V
Primary current: 100 A - 10,000 A
... opposite phase at the same amplitude. Power factor correction The Aunilec APF not only compensate harmonic current but also the reactive power. It is able to correct for either a leading or lagging power ...