The SPT-61 module is equipped with Pt 100 / Pt 500 /
Pt 1000 type input with automatic recognition of 2- and
3-conductor connection. Due to precision of measurement
3-wire circuit is recommended. The measurement range
spans from -100°C to +600°C, ...
The smart non-isolated transmitter SPT-85, is
designed for in-head or DIN-rail mounting.
This transmitter allows the user to:
- select sensor and input signal type (4 ...
SPT-86L module is the insulated temperature and voltage to
current in the 4-20 mA standard transmitter, and has
possibility of data reading via RS-485 interface. It has one
input (Pt 100/500/1000, thermocouples K/S/J/T/N/R/B/E, 0-
60 / 0-75 / 0-100 / 0-150 mV) and one ...
DLU - DLU2
DIN rail surge protector for Telecom line
DLU and DLU2 surge protectors are designed to protect, against surge ...
DLR
1-wire compact DIN surge protector
DLR surge protectors are designed to protect, against surge voltages due to ...
DLA-EX
DIN rail plug-in Surge protector for Dataline - ATEX
DLA-EX surge protectors are designed to protect against ...
Description
Emergency power supplies with Ni-Mh batteries.
...
Description
Emergency power supplies with Ni-Mh ...
Description
Emergency power supplies with Ni-Mh batteries.
...
These DIN rail module box kits are the perfect enclosures for a wide ...
14-50 DIN Rail PLC Enclosure
- Suitable for sorts of modualarization PCB, controller ...
These DIN rail terminal enclosures offered by Dayang Enclosures are the perfect enclosures ...
MONORAIL BZ - toothed rack system
An innovative drive concept
With the toothed system MONORAIL BZ SCHNEEBERGER offers a linear guide system with various classes of precision. This extends the characteristic performance of ...
MR = Roller MONORAIL
For all machine-tool applications in which precision, ...
BM = Ball MONORAIL
Thanks to their minimum vibration ...
Type 3 surge arresters are installed downstream of type 2 surge arresters in sub-distribution boards close to the loads in single or multiphase systems and further limit the overvoltage ...
These devices for measuring voltages and currents can be used for monitoring input and output currents or device currents in electric plants. ...
These devices for measuring voltages and currents can be used for monitoring input and output currents or device currents in electric plants. ...
Universal rail mounted HART temperature transmitter in a compact 17.5 mm housing. The TTR200 transmitter provides increased device safety in ...
The TH102 / TH102-Ex is a via HART-protocol programmable loop powered rail mounted temperature transmitter. A PC with the software package SMART VISION or ...
Anacon's "Cool One" heat sink designs provide a thermally optimized DIN & Panel Mount platform ...
Anacon's "Cool One" heat sink designs provide a thermally optimized DIN & Panel Mount platform for today's high performance solid state relays.
All Anacon Solid State Relay Assemblies use relays tested to UL508A SCCR ...
• New generation of SSR for DIN rail fixation.
• ...
• New generation of SSR for DIN rail fixation.
• ...
The Conax Model 6333A is a DIN rail mount programmable 2-wire transmitter, featuring a state-of-the-art microprocessor-based design that enables full configuration with user friendly configuration software.
Features:
RTD or Ohm Input
High ...
The Conax Model 6334A is a DIN rail mount programmable 2-wire transmitter, featuring a state-of-the-art microprocessor-based design that enables full configuration with user friendly configuration software.
Features:
TC or mV Input
Extremely High ...
kWh meter single and three phase DIN rail mounting
Compact housing
Available for ...
kWh meter single and three phase DIN rail mounting
Compact housing
Available for ...
time delay relay
multivoltage
multifunction
changeover ...