Mass flow meter / Coriolis / for liquids / with mass flow controller
MTCMF Dandong Top Electronics Instrument (Group) Co.,Ltd

Characteristics

  • Technology:

    mass, Coriolis

  • Fluid:

    for liquids

  • Other characteristics:

    with mass flow controller, digital display, precision, high-accuracy, economical, stainless steel, high-temperature, two-sensor, fraud-proof, ATEX, IP67, explosion-proof, intrinsically safe, corrosion-resistant

  • Applications:

    industrial, for the food industry, for the petrochemical industry, for the pharmaceutical industry, for dosing, for low-density materials, laboratory, for high-density materials, high-pressure, for tanks

  • Process pressure:

    Min.: 0 bar (0 psi)

    Max.: 40 bar (580.15 psi)

  • Process temperature:

    Min.: -20 °C (-4 °F)

    Max.: 60 °C (140 °F)

  • Volumetric flow rate:

    Min.: 0 m³/h (0 ft³/h)

    Max.: 600 m³/h (21188.8 ft³/h)

Description

MTCMF Mass Flow Meter Overview

Coriolis mass flow meter (MTCMF) is a new type flow meter which is designed according to Micro Motion and Coriolis principle. This kind of new flow meter can measure the fluid directly in a sealed pipeline. It consists of two sections: Sensor and Signal Transmitter.

1 Main Features

Unchallengeable performance on liquid mass flow, volume flow, and density measurement
Unique design delivers unparalleled measurement sensitivity and stability
Guarantees consistent, reliable performance over the widest flow range
Designed to minimize process, mounting, and environmental effect

2 Application

 Chemical: containing chemical reaction system
 Petroleum: moisture content analysis
 Lipids: including vegetable oils, animal fats and other oils
 Pharmaceutical
 Painting
 Paper making
 Textile printing and dyeing
 Fuel
 Food
 Transportation: pipeline liquid measurement.
 Low temperature fluid
 High temperature fluid, the maximum temperature up to 300℃
 High pressure fluid

3. Technical Parameters

Accuracy(Liquid) :( With FT-522 Transmitter):
±0.1% ±(zero stability/measurement value)%
Density(Liquid) measuring range and accuracy (With FT-522 series transmitter)
Range: 0.3~3.000g/cm3 Accuracy: ±0.002g/cm3
Temperature measuring range and accuracy (With FT-522 transmitter):
Temperature measuring range: -200~350℃ Accuracy: ±1℃
Ambient temperature: -20℃~60℃
Material : The measuring tube SS316L Housing: SS304
Working pressure: 0~4.0MPa
Explosion-proof level : Exd (ia) ⅡC T6Gb