|
Explosion proof cable gland for armored cables HawkeApplication
Outdoor or Indoor use. For use with non-armoured elastomer and plastic insulated cables. Features Provides a cable retention seal onto the cables outer sheath. When used in increased safety applications, this cable gland may be used with braided cable where the braid and the cables outer sheath pass into the enclosure. The braid must be suitably terminated inside the enclosure. Materials & Finishes The 501/421 Cable Gland is manufactured as standard in Brass, Stainless Steel and Aluminium. NPT entries are nickel plated as standard. Full nickel plating by electroplating or electroless plating is also available, as are other materials on request. Technical Data Flameproof Exd and Increased Safety Exe. II 2 GD Baseefa Certificate No. BAS01ATEX2070X. For sizes Os - F. Baseefa Certificate No. BAS01ATEX2294X. For sizes G - J. The above certificates are still current, however they are to be superseded by: Baseefa Certificate No. Baseefa06ATEX0056X. IECEx Certificate No. IECEx BAS 06.0013X. Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22. Suitable for use in Gas Groups IIA, IIB and IIC. Construction and test standards EN 50014,EN 50018, EN 50019 and EN 50281-1-1. IEC 60079-0, IEC 60079-1 and IEC 60079-7. IP 66, IP67 and IP68 (30 metres for 7 days) ingress protection to IEC 60529, EN 60529 and NEMA 4X. |






