- Materials - Tools - Components >
- Standard Mechanical Component >
- Brass cable gland
Brass cable glands
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}

Cable diameter: 1 mm - 99.99 mm
Thread diameter: 20 mm - 32 mm
Operating temperature: -40 °C - 140 °C
EMC cable gland EVolution EMC Sealing insert made of silicon with anti-twist protection and slotted solution (changeable for service) Pluggable shield contact solution Vibration-proof design ...

Cable diameter: 110 mm
Operating temperature: -40 °C - 200 °C
... impacts. UNI Dicht meets all the current EU requirements for cable entries as well as relevant international certifications such as UL and CSA. A UNI Dicht cable gland consists of ...

... 2.5 GHz, the values are typically a minimum of 50 dB. The cable gland also has a very high current-carrying capacity. The cable gland blueglobe TRI is available in ...

Cable diameter: 3 mm - 44 mm
Thread diameter: 12 mm - 48 mm
... type cable glands manufactured in nickel plated brass with eiter PG or metric thread. Protection similar to IP 68 is achieved by employing a fully insulated Neoprene cable ...

Cable diameter: 5 mm - 42 mm
Thread diameter: 16 mm - 63 mm
This EMC / EMI cable gland is designed to ground cable braids directly to the wall with optimum contact to the periphery of the gland base. Built-in twisting protection, ...

Thread diameter: 16 mm - 63 mm
... larger thread size in order to accept a suitable gland. Configuration: From small external Metric to large internal Metric and from small external PG to large internal PG. Material: Brass, nickel plated

Operating temperature: -60 °C - 130 °C
The E1FW cable gland is a brass cable gland specifically for cables with steel-wire armouring (SWA). The E1FW provides a pressure-proof ...
ROSE Systemtechnik

Operating temperature: -30 °C - 150 °C
Cap nut: - Polyamide PA6 V2 / Brass with nickel plated Sealing ring: - TPV (special seal for RJ-45 cables) Gland body: - Polyamide PA6 V2 / Brass with ...
ORTAC

Operating temperature: -20 °C - 150 °C
... - TPV (special seal for RJ-45 cables) Gland body: - Brass with nickel plated O-ring: - NBR (optional) Connection thread: - Metric (EN 60423) / PG (DIN 40430) Benefits: ...
ORTAC

Cable diameter: 6.1 mm - 123.3 mm
Operating temperature: -60 °C - 180 °C
Type: - WDCG (Double compression gland) Certificate: - PT-CE-Rohs-ISO9001-14001-Ohsas 18001 Material: - MS58 brass with or without nickel plated stainless steel AISI303 / 316L / Aluminium Standards: ...
ORTAC

Cable diameter: 3 mm - 44 mm
Operating temperature: -40 °C - 100 °C
Cable gland made of nickel plated brass Clamping insert - Polyamide V0 according to UL 94 Material - Nickel-plated brass,Nickel-plated brass (lead-free) Material ...
HUMMEL

Cable diameter: 2 mm - 44 mm
Operating temperature: -35 °C - 150 °C
Cable gland for chemical and high temperature applications made of nickel plated brass Clamping insert - PVDF Material - Nickel-plated brass Material o-ring - FKM NEMA ...
HUMMEL

Operating temperature: -40 °C - 100 °C
Multi cable gland made of nickel plated brass Clamping insert - Polyamide V0 according to UL 94 Material - Nickel-plated brass Material o-ring - NBR Protection class ...
HUMMEL

Cable diameter: 3 mm - 52 mm
Thread diameter: 8 mm - 22 mm
Operating temperature: -40 °C - 100 °C
Heyco®-Tite Brass Liquid Tight Cordgrips Straight Thru, NPT Hubs The Ultimate in Liquid Tight Strain Relief Protection FEATURES - Nickel plated brass construction for superior protection of flexible ...
Heyco

Cable diameter: 5.5 mm - 104.5 mm
Thread diameter: 0.5 mm - 4 mm
Operating temperature: -80 °C - 60 °C
... IECEx glands for armoured cables. the gland is designed to provide armour clamping by using one clamping arrangement for all armour/braid types. it also provides the cables ...

Cable diameter: 5.5 mm - 104.5 mm
Operating temperature: -60 °C - 80 °C
... suitable for cables that exhibit "Cold Flow" characteristics. It provides a patented diaphragm seal on the cables inner sheath to avoid damage especially of soft and flame retardant cables. Available ...
Jacob GmbH

Cable diameter: 3.2 mm - 68.2 mm
Operating temperature: -60 °C - 100 °C
HAWKE 501/414 Ex d cable gland is suitable for the installation of protection hoses and conduits. It provides an elastomeric Ex d flameproof seal on cable outer sheath. Available ...
Jacob GmbH

Operating temperature: -60 °C - 80 °C
... suit core size. Female running coupler for cable gland or conduit entry. Can be used to upgrade standard non-barrier gland into a flameproof Ex d barrier gland. Available ...
Jacob GmbH

Cable diameter: 3.4 mm - 90 mm
Thread diameter: 20 mm - 100 mm
Operating temperature: -20 °C - 85 °C
Features: Typical examples LIGHT&SOUND combinations a new standard ATEX with terminals box.
KROMA MEC SRL

Cable diameter: 4 mm - 78 mm
Thread diameter: 27 mm - 100 mm
Operating temperature: -40 °C - 100 °C
The ATEX II2GD model is a liquid-tight strain relief cable gland that is either fabricated from brass or stainless steel. Designed for use in indoors possessing high humidity, it is an ...
KROMA MEC SRL

Cable diameter: 4 mm - 78 mm
Thread diameter: 0.5 in - 4 in
Operating temperature: -40 °C - 100 °C
... Liquid-tight Strain Relief Cable Gland is an IP 66 rated cable gland designed for operations in indoors with increased humidity. It is also applicable to oils and dusts ...
KROMA MEC SRL

... details Materials: Brass Thread: G(PF) Features: With reliable installation, good protection and explosion-proof function. Applications: The product suitable for clamping and fixing steel wire ...
Shenzhen Milvent Technology Co.,Ltd

Product details Thread:Metric,,PG, G(PF), NPT Material: Brass with nickel plated for A.C. F parts. NBR for seal and sealing washer. UL approved nylon PA66 for claws. Protection degree: IP68 Working ...
Shenzhen Milvent Technology Co.,Ltd

Operating temperature: -40 °C - 100 °C
Product details Thread:Metric,,PG, G(PF), NPT Material: Brass with nickel plated for A.C. F parts. EPDM for seal and sealing washer. UL approved nylon PA66 for claws. Protection degree: ...
Shenzhen Milvent Technology Co.,Ltd

Cable diameter: 3 mm - 62 mm
Thread diameter: 12 mm - 75 mm
Operating temperature: -40 °C - 100 °C
Protection classIP68 (5 bar 30 min) / IP69 Temperature range-40 °C - 100 °C MaterialGland Brass nickel-plated, Clamping cage Polyamide, Gasket EPDM
WISKA Hoppmann GmbH

Cable diameter: 30 mm
Operating temperature: -20 °C - 80 °C
M20x1,5 / TL=17,0mm Corrosion Proof Cable Gland for SWA and AWA Cables BCW-21 Cable Gland with Hybride Structure (Brass and ...
Bimed Teknik Aletler

Cable diameter: 6 mm - 110 mm
Thread diameter: 16 mm - 120 mm
Operating temperature: -40 °C - 125 °C
Industrial Brass Cable Glands. Double Compression Gland, Single Compression Glands. Type A2 Glands, Type BW Glands, ...

Operating temperature: -40 °C - 120 °C
• Material: Brass, chromium plated • Protection degree: IP54 • Temperature Resistance: -40°C-100°C, short time to 120°C. • Application: outdoor and indoor use for all types of braided or unarmoured marine electrical ...
Yueqing Yingfa Cable Accessories Co., Ltd.

Cable diameter: 5 mm - 27 mm
Thread diameter: 20 mm - 32 mm
Brass Cable Glands, available for stainless steel materials.
Tianjin Driflex Co., Ltd.

Cable diameter: 12 mm - 42 mm
... industry. Cable glands – Standard series, Spiral cable glands, Flange lock nuts, Hexagonal metric blind stops, Round metric & PG blind stops, Metric plastic cable ...

Cable diameter: 16 mm - 100 mm
Thread diameter: 24 mm - 114 mm
Clamping range: 4 mm - 90 mm
Material: - Brass Sealing: - Chloroprene / Neoprene (Silicone on request) Connecting Thread: - Metric / NPT Cable glands for industrial applications In the field of industrial ...

Cable diameter: 5 mm - 104 mm
Thread diameter: 16 mm - 110 mm
Material: Brass or stainless steel, brass with nickel plated Cable: With packing seal Protection Class: IP66 Explosion Mark: Exd II Features: With quick installation, ...
YUEQING JIXIANG CONNECTOR CO., LTD

Cable diameter: 11 mm - 21 mm
Operating temperature: -40 °C - 150 °C
... meet the normal operation of the product in the cold weather. 4. This product to achieve clamping ring and cable surface contact seal, the cable damage is small, can effectively prevent access to the ...

... range of Cable Glands and Accessories are widely used for installation in explosive atmospheres. Types of Cable Glands •A2 Type Cable Glands •CW ...

Cable diameter: 2 mm - 84 mm
Thread diameter: 8 mm - 100 mm
Operating temperature: -40 °C - 100 °C
Studio division, responsible for overall planning for community by the studio, under the creative group, group activities, outreach group and financial group of four departments, each department of mutual development, mutual exchanges ...
YUEQING HONGXIANG CONNECTOR MANUFACTRER CO., LTD

Cable diameter: 3 mm - 44 mm
Thread diameter: 12 mm - 100 mm
Operating temperature: -40 °C - 120 °C
Brass cable glands Thread: Metric, PG, G(PF), and NPT thread Brass with nickel plated for A. C. F parts, UL approved Nylon PA66 (Flammability UL 94V-2) ...
Zhejiang BangNai Electric Co. Ltd

... Manufacturers, Suppliers and Exporter. For manufacturing these components, we ensure that fine quality of brass metal is used. Further, we also see to it that the brass alloy has the required ratio of ...

Cable diameter: 3.2 mm - 79.9 mm
Operating temperature: -60 °C - 130 °C
Industrial Cable Gland with Conduit Connection Facility • Designed for rigid & flexible conduits • Easy install running coupler design • Displacement type seal • Designed to prevent Coldflow • -60°C to +130°C
CMP Products
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining