- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Other flow, pressure and level measurement equipment
Other flow, pressure and level measurement equipment
Cooling Fin Type (CF-type) Temperature Limit: -10~400ºC Material: SS316L Length: 90, 100, 124mm Capillary Tube Type (CT-type) Temperature Limit: -200~600ºC Material: SS316L
The VRD-ANB-CD vacuum regulator is constructed to control the output vacuum from ) psig to its full vacuum. It is especially helpful in minimizing the weight and space. The unit weighs up to 25 grams and it is composed of brass and stainless ...
Measurement principle Flow measurement is calculated via the maximum velocity measurement. Pitot tube is placed at the centre of the pipe. The shape speed depends of the number of the Raynolds. Velocity is equal to ± 2% and to maximum ...
ERW700 Flow rate and thermal energy calculator for liquids, gases and water steam ERW 700 uses input data such as flow (differential pressure), pressure, temperature and density to calculate the volume, standard volume and mass of liquids, ...
The thermal energy and heat meter IFX-E3 is designed for domestic and service sector applications and links the flexibility of the “ONE” function (Optimized & Nimble Elaboration) with the opportunity to have different protocols simultaneously. Its ...
ISOIL Industria Spa
Water Meters for cold water up to 50 ºC and for hot water up to 130 C from DN 40 to DN 300 Hermetically sealed register (IP 68) Patented hydrodynamically balanced rotor Patented symmetrical calibration adjustment Register may be ...
ISOIL Industria Spa
The thermal energy meter IFX-E4 is designed for residential and office application and link the different protocols with the “ONE” function. With a composite measuring pipe, the IFX-E4 is the perfect solution for homes and offices, ...
ISOIL Industria Spa
Frequency: 40, 25, 30 kHz
The Original – SONOPUSH® Rod Transducer The SonoPush Rod Transducers can be operated with up to 2000 W power output. They are available in a range of lengths and models. The different models are suitable for a large variety of industrial ...
Weber Ultrasonics
Frequency: 25, 30, 40 kHz
The Original – SONOPUSH® Rod Transducer The SonoPush Rod Transducers can be operated with up to 2000 W power output. They are available in a range of lengths and models. The different models are suitable for a large variety of industrial ...
Weber Ultrasonics
Frequency: 25, 30, 40 kHz
The Original – SONOPUSH® Rod Transducer The SonoPush Rod Transducers can be operated with up to 2000 W power output. They are available in a range of lengths and models. The different models are suitable for a large variety of industrial ...
Weber Ultrasonics
MASTER LEAK LEAK DETECTOR-CALIBRATION CHECKING Master leaks are used for checking calibration and calibrating ATEQ Leaktesters from the F and G range. The leaks are delivered with a certificate of calibration in a protective ...
The Move It! Evaluation Kit is an open IMU using the Murata SCHA63T-K01 6-DoF 125dps sensor together with a powerful 32-bit processor. Via coniguration of software different sensors can be compared. The Murata high performance 2-axis ...
The Model 1088 boiler gauge are specially constructed with a brass connections and movements to withstand conditions inherent in residential hot water heating systems. Their low cost and reliable performance also make them a viable choice ...
Calibrated Leaks Made to your Requirements ION Sciences calibrated leaks are small fittings that deliver a specific gas leak rate, often used to set pass/fail thresholds on leak detection systems or leak detection instruments. Each calibrated ...
Cylinder pitot tube for velocity measurement in pipelines • For measure speed after the dynamic pressure method • Material brass (up to 100 °C) or stainless steel (up to 450 °C) • Pressure connection 6mm • Diameter 24 mm, length ...
Arthur Grillo GmbH
MEASURING GRID SGI for air measurement in pipelines • For measure speed after the dynamic pressure method • Arrangement of several cylinder pitot tube • Central tubes with laterally attached probe tubes • Material brass (up to 100 ...
Arthur Grillo GmbH
Heat transfer steam Temperature range 100… 600 °C 1…100 bar pressure range Pressure input mA 0/4…20 Any flow sensor with analog signal connected 2 x Pt100 inputs for steam and condensate temperature Coefficient ...
Arthur Grillo GmbH
1/4NPT male to various connectors Designed for all pumps except Additel 949 ,959,960 pumps Can be ordered as an entire kit or as individual parts (see datasheet) 1/2'' NPT male, 1/4'' BSP male, M20*1.5 male are available per request 1/4NPT ...
Data logger ALMEMO® 202-S and ALMEMO® 204 generation V7 •ALMEMO® professional measuring instrument, latest V7 generation •with data logger function •two or four measuring inputs for all digital ALMEMO® D6 and D7 sensors, for ALMEMO® ...
Ahlborn Mess- und Regelungstechnik GmbH
• Compact ALMEMO® measuring instrument • 1 measuring input • over 35 measuring ranges • Generously dimensioned 2-row segment display including units • Easy and convenient to operate by means of 7 keys. • Over 35 measuring ranges ...
Ahlborn Mess- und Regelungstechnik GmbH
• ALMEMO® professional measuring instrument with data logger function • Functions for all application areas • 1 or 2 measuring inputs • Also with integrated sensor for temperature, atmospheric humidity, atmospheric pressure Technical ...
Ahlborn Mess- und Regelungstechnik GmbH
Four (differential) pressure measurement ranges Measured values are displayed in 8 units: mbar, Pa, hPa, kPa, mmHg, inHg, psi, bar Automatic zero calibration Hold function for short-term freezing of measured value Fully automatic ...
S1XMmM Universal Current / Voltage Converter, universal sensor input, Analog Output and RS485 Modbus RTU, RMS, AC and DC measurement, Min / Max and Average measurement, Frequency and Crest factor measurement, temperature and resistance ...
- Electronic Dual Temperature Switch for temperature control - Continuous temperature measurement from 0 ... 100°C to -30 ... 140 °C - Max. 4 outputs - 1 or 2 level set point, fixed set points depending on configuration - Rotatable ...
•Level measurement on reed-contact basis •With adjustable container screw joint •Various hose connection sets and elbows available •Available with pipe length up to 1200 mm •Material: PVC, PP, PVDF •Contact form: N.O., N.C., changeover •Up ...
Recordall® Disc Series meters are an accurate, cost-effective solution for your metering needs. These positive displacement meters utilize the industry-leading nutating disc technology to drive accuracy and reliability. Precision ...
Badger Meter
Multichannel high accuracy environmental data acquisition • temperature sensors with integrated electronics • high accuracy and easy interchangeability • 5 wired and up to 15 wireless sensors are available, extension of sensor number ...
Pressure: 1 bar - 2,600 bar
A range of very accurate and stable pressure standards that is commonly used across industries to calibrate pressure measurement devices and instrumentation like pressure transmitters and gauges. Models are available for pneumatic ...
TAKUWA’s staff gauges have high visibility for manual water level observation with less reading error. ■High Visibility by Using Rétro-Reflective Sheet, Sophisticated Design with 5 colors ■Robust Stainless (Aluminum is available as ...
The 3DPro2300 radar scanner accurately detects the 3D information of solid materials and buildup on silo walls. It integrates image processing technology, big data analysis, artificial intelligence, machine learning, 3D point cloud conversion, ...
The INVONIC2-DIN product is an advanced meter with an extremely flexible configuration designed to meet the specific needs of users. This meter is provided in user configuration mode, offering the ability to customize a wide range of ...
Measuring principle turbine bypass Measuring range up to 450 m³/h Mechanical register Process connection from DN50 to DN200 Materials Cast iron Temperature up to 50°C Waters particularly dirty, as for example in agriculture, ...
Frequency: 15 kHz
Distance range: 1 m - 60 m
AIRMAR's ART15 Airducer Provides the Longest Ultrasonic Range Available The ART15 is an ultrasonic Airducer which can deliver long range level measurements on both solids and liquids. With a range of up to 60 m (197'), the ART15 is ...
Airmar Technology
Frequency: 30 kHz
Distance range: 60 cm - 3,000 cm
AR30 Airducer® Transducer Applications: - Level measurement - Proximity - Obstacle avoidance - Traffic control Features: - Rugged sealed construction - Housing design will accommodate transceiver and signal processing electronics - ...
Airmar Technology
Frequency: 30 kHz
Distance range: 60 cm - 3,000 cm
Applications: - Level measurement - Level measurement in chemically aggressive environments - Food and beverage processing - Proximity sensing - Obstacle avoidance Features: - Rugged sealed construction - Housing design will ...
Airmar Technology
Not only source pressure, terminal pressure can be controlled. Push-lock knob for easy adjustment. Push-lock knob for easy pressure adjustment. Realized max. 50% of weight saving compared to conventional model. The main body is made ...
Ultrasonic water meter • Nominal diameter: DN15/DN20/DN25 • Dynamic range: Q3 / Q1 R250 / R400 / R800 / R1600 • Installation sensitivity class: U0/D0 • Temperature class: T30/T50 • Metrological class: Class 2 • Pressure rating: ...
Ultrasonic water meter with integrated valve • Integrated shut off valve • Nominal diameter: DN15/DN20 • Dynamic range: Q3 / Q1 R250 / R400 / R800 / R1600 • Installation sensitivity class: U0/D0 • Temperature class: T50 • Metrological ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining