- Robotics - Automation - Industrial IT >
- Automation >
- 24V DC repeater
24V DC repeaters
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
... In/ I.S In 500 V; Out/Supply 500 V; Out/Out 500 V. - Operating temperature: –40 to +70 °C. - Storage temperature: –45 to +80 °C. - Equipment: Associated apparatus and non-sparking electrical equipment. - ...
... The Switch/Proximity Detector Repeater D5030 is a module suitable for applications requiring SIL 3 level in safety related systems for high risk industries. The unit can be configured for switches or proximity detectors, located in Hazardous ...
... unit Technical Specifications: - Supply Voltage: 24 Vdc nominal (18 to 30 Vdc), reverse polarity protection - Current Consumption: 57 mA at 24 Vdc with 20 mA output, typical - Power Dissipation: 1.50 W at 24 ...
... channel is provided with a LED indicating that this channel has originated a CAN message. CAN Repeater CRep S4I/FD Protocol transparent CAN repeater for CAN FD and CC 4 individually galvanically isolated ...
EMS Dr. Thomas Wünsche e.K.
... The compact CAN repeater CRep S8C transmits and amplifies signals transparent to the CAN protocol. Each of the eight CAN connections has the physical behavior of a single bus node. CRep S8C permits a flexible design of the network topology ...
EMS Dr. Thomas Wünsche e.K.
... The compact CAN repeater CRep S10I transmits and amplifies signals transparent to the CAN protocol. Each of the ten CAN connections has the physical behavior of a single bus node. CRep S10I permits a flexible design of the network topology ...
EMS Dr. Thomas Wünsche e.K.
... The compact CAN repeater CRep S26 transmits and amplifies signals transparent to the CAN protocol. Each of the 26 CAN connections has the physical behavior of a single bus node. CRep S26 permits a flexible design of the network topology ...
EMS Dr. Thomas Wünsche e.K.
... The assembly rail mountable CAN repeater CRep N transmits and amplifies CAN signals in a protocol transparent way. CRep N allows the design of flexible wiring topologies. Star and tree structures as well as stub lines can be realized. ...
EMS Dr. Thomas Wünsche e.K.
... Isolation - DC 1500 V electrical isolation - Physical - Size(LxWxH) - 113 x 100 x 21 mm - Weight - approx.120g - Operating temperature - -40°C~85°C - Humidity - 15 to 95% non-condensing - Power supply Power ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group