... input with/without compensation for cable resistance in two ranges -50 to 300°C and -50-100°C . • Output 0-10VDC/2-10VDC/0- 20/ 4- 20 mA - selected via terminals. • Output offset and gain ...
Brodersen Controls
... battery (guarantees measurement in the absence of power) 4 GB data logger BIV self-checking function of the electrical characteristics of the sensor. Description The converter with display for magnetic flow meters ...
... The 2/ 4-Wire Transmitter Trip Amplifier D6254 provides a fully floating dc supply to energize conventional 2 wires 4- 20 mA transmitters located in Hazardous Area; it also accepts 0/ 4- 20 ...
... The Temperature Converter & Trip Amplifier D6273 accepts a low level dc signal from millivolt, thermocouple or 2-3- 4 wire RTD or transmitting potentiometer sensors, and converts, with isolation, the signal to drive a ...
... Software allows the user to configure and test the system via USB and a computer. There is easy access to the USB connection to allow adjustment of settings without the need to uninstall the unit. The USB ...
... The isolated frequency converter DAT 4540 is able to measure, up to 20 KHz, the frequency of TTL, Namur, NPN, PNP and Tachometer digital signals. In function of programming, the measured values are converted in a current ...
DATEXEL SRL
... 31712-00 type are digital converters for a rod head using the 2-wire technique Input : PT 100 ohm or thermocouple J K T R S B or mv Output: 4/ 20 mA programmable for scale, response time ...
Vulcanic
... designed to convert RTD100, thermocouples, potentiometer, mA, mV and other standardized current signals coming from the hazardous area to the safe area. Output: up to 2 4/ 20 mA outputs ...
... hot-plug module CAN MK- 4I 4O is wirelessly connected to the CAN bus with 4 additional inputs/outputs, in order to link with weighing indicators. One analog board (0/10 V or 4/ 20 ...
... These Current Converters accept a 24Vdc power supply (nominal) and a 4- 20 mA input signal converting it to a 0-200 mA current output. Span and zero is user adjustable. ...
... A/D converter, which guarantees high accuracy and excellent stability. Input: 0…2/5/10 V 0…5/ 20 mA, 4… 20 mA, passive/active Analogue ...
... resistance thermometer values into a standard 4- 20 mA current signal in all areas of the industry. Converter’s configuration can be easily set by the user as requested by using USB ...
... air consumption due to piezo electric microvalve Model - IPC Input signal - 4 ~ 20㎃ @ 24 VDC , 2-wire Output pressure - 0 - 1bar (0 - 15psi) 0.2 - 1bar (3 - 15psi) 0. 4 - 2bar (6 - 30psi) 0.2 ...