- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Biogas flow meter
Biogas flow meters
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
... MULTIVARIABLE
BIOGAS
FLOW
METER – SOL BIOGAZ
CERTIFIED CUSTODY TRANSFER METERING FOR LANDFILL AND WWTP GAS
SOL BIOGAZ is a multi-channel differential pressure Pitot ...
Process temperature: -55 °C - 250 °C
Process pressure: 18.63 bar
Precision: 1.5, 1, 2.5 %
... reliable ultrasonic flow measurement system for monitoring wide ranging gas flow in challenging conditions. PanaFlow FLI is available in either a flowcell (spoolpiece) or nozzle only design providing ...
Process temperature: -55 °C - 75 °C
Process pressure: 1 bar - 187 bar
Precision: 1.5, 2 %
... purpose gas flow meter that offers a rugged transducer, weatherproofing, and is approved for use in hazardous environments. The XGM868i is accurate over a wide range of flows and compositions ...
Process temperature: -40 °C - 85 °C
Precision: 1.5, 1 %
... The PanaFlow Gas Meter System consists of two models—the one-path PanaFlow Z1G and the two-path PanaFlow Z2G. Both meters offer a high-performance, yet affordable solution for a variety of gas ...
Process temperature: -40 °C - 100 °C
Process pressure: 0 bar - 10 bar
... Ultrasonic flowmeter OPTISONIC 7300 Biogas Ultrasonic flowmeter for biogas, landfill and sewage gas applications* 1- or 2-path meter for low pressure ...
Volumetric flow rate: 0 m³/h - 32,979.6 m³/h
Process temperature: -40 °C - 121 °C
Process pressure: 500, 230, 285 psi
... constant differential temperature as heat is siphoned into the gas is proportional to the mass flow rate. Gas Flow Measurement in the Water and Wastewater Industry The MDot™ Thermal ...
Process temperature: -10 °C - 40 °C
... Commercial and industrial use/ for biogas only BF-3000 Ultrasonic Biogas Flowmeter is developed for the measurement of biogas output from anaerobic digester. It is designed to withstand ...
Volumetric flow rate: 3 m³/h - 800 m³/h
Process temperature: -10 °C - 40 °C
Process pressure: 0 Pa - 200,000 Pa
... Ultrasonic Biogas Flowmeter is based on technology combination of pressure differential and ultrasonic transit time differential measurement method. With a bypass structure in the flow meter, ...
Process temperature: -18 °C - 121 °C
Process pressure: 34, 10 bar
Precision: 0.5, 1, 2 %
... compact, low cost solution for accurate, repeatable flow measurement of biogas, digester gas, landfill gas, methane and natural gas as well as air, compressed air or nitrogen. This insertion-style flow ...
Precision: 1 %
... Overview
YUNYI NB wireless Roots
flow
meters (rotary
gas
meters) are volumetric
gas measurement instruments designed for high-precision, repeatable metering. ...
Precision: 1 %
... Overview
YUNYI Lora Wireless Roots
flow
meters, also known as
gas rotary
flow
meters, are high-precision, highly reliable
gas metering instruments ...
Process temperature: -20 °C - 350 °C
Process pressure: 1.6, 2.5, 4 MPa
Precision: 1.5, 1 %
... YUNYI intelligent vortex flow meter is a new type of gas flow instrument based on the vortex shedding principle. Its core lies in utilizing the stability of the Strouhal number within ...
Process temperature: -196 °C - 450 °C
Process pressure: 6 bar - 420 bar
Precision: 0.2, 1, 0.5, 2.5, 1.5 %
... flow meter developed by modern digital intelligent processing technology. Application : ●Natural gas, flare gas, and other gas flow measurement ●Compressed air measurement ●Oxygen, ...
Volumetric flow rate: 1 m³/h - 6,000 m³/h
Process pressure: 16 bar
Precision: 1 %
... ultrasonic gas flow. Application : ●Natural gas, flare gas, and other gas flow measurement ●Compressed air measurement ●Oxygen, nitrogen, hydrogen, chlorine and multi-component gas ...
Process temperature: 0 °C - 50 °C
Process pressure: 16 bar
Precision: 1.5 %
... Elemental Analysis, Gas Chromatography, ICP Spectroscopy, OES Spectroscopy, Mass Spectrometry
... Compressed air and natural gas meters with M-Bus - now directly from the manufacturer. CS Instruments GmbH & Co. KG was the OEM-manufacturer of the ENDYS AIR compressed air meter with M-Bus from 2010 to the end of ...
Process temperature: -40 °C - 121 °C
Process pressure: 10 bar - 51 bar
Precision: 0.2, 1, 1.5, 0.5 %
... Field-Selectable Gases-air, methane, digester gas Direct mass flow measurement maintains precise control of aeration, digestion, and cogeneration Insertion and inline versions AC or DC power input available Optional ...
Sierra Instruments
Volumetric flow rate: 3 m³/h - 650 m³/h
Process temperature: -10 °C - 60 °C
Process pressure: 6 bar
... principle is a method used to measure the volumetric flow of gas in various applications. This instrument offers a wide range of applications since, depending on the configuration, the measured flow rates ...
Volumetric flow rate: 0.1 m³/h - 110,000 m³/h
Process temperature: -40 °C - 150 °C
Precision: 0.5 %
... ; 20 ÷ 36 Vac/Vdc; 11 ÷ 13Vdc Reverse Flow - Instant measure and totalization of reverse flow Flow Cutoff - Adjustable. Below selected value, instantaneous flow and outputs ...
Process temperature: 350, 250 °C
Process pressure: 16 bar
Precision: 1.5 %
... Flange wafer type vortex flowmeter is a new type of flow meter. It adopts wafer type connection, together with flanges, bolts & nuts, easay installation. Vortex flow sensor have pulse ...
Process temperature: -40 °C - 60 °C
... control Process gases Dry, wet, corrosive and abrasive gases Gas such as sour gas or biogas with H2S The main applications of the FioSonic Ultrasonic Flow Meter ...
Process temperature: -40 °C - 350 °C
Process pressure: -1 bar - 63 bar
Precision: 1, 0.75 %
... manufacturers. Find vortex flow meter firms that can design, construct, and produce vortex flow meters according to your needs. Then, using our simple request for quote form, contact ...
COMATE
Process temperature: -40 °C - 150 °C
Process pressure: 10 bar
... technology to provide proportional mass flow measurement resulting in higher accuracy performance at a lower cost than orifice flow meter, Vortex shedding flow meter ...
Process Control Devices
Volumetric flow rate: 3 m³/h - 3,200 m³/h
Process temperature: -10 °C - 40 °C
Process pressure: 0 Pa - 200,000 Pa
... Introduction BF-3000 Ultrasonic Biogas Flowmeter can be commonly used with various industrial gas streams( biogas, natural gas, air, etc.), but with special design to enable it withstand the wet and corrosive ...
Volumetric flow rate: 3 m³/h - 3,200 m³/h
Process temperature: -10 °C - 40 °C
Process pressure: 0 Pa - 200,000 Pa
... Ultrasonic Biogas Flowmeter is based on technology combination of pressure differential and ultrasonic transit time differential measurement method. With a bypass structure in the flow meter, ...
Volumetric flow rate: 0.1 m³/h - 4 m³/h
Process temperature: -10 °C - 40 °C
Process pressure: 0 Pa - 20,000 Pa
... Introduction BF-2000 Residential Gas Meter is a pre-paid type gas meter embedded with Cubic’s ultrasonic gas module which have self-owned intellectual property. It is ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group