Process temperature: -40 °C - 70 °C
Process pressure: 0 bar - 16 bar
... Mounting flexibility - compact or separate installation possible • Validated calibration ensures accurate flow measurement. Each Siemens flowmeter is calibrated in facilities that are individually accredited ...

... ultrasonic flowmeter provides the most essential flow measurement functionalities with superior accuracy, cost efficiency and ease of use. It is the best-in-class solution for straightforward flow ...

Process temperature: -20 °C - 80 °C
Process pressure: 0 bar - 0.69 bar
Repeatibility: 0.5 %
... Area Velocity Flow Measurement method is the most common method of all flow measurements. The AVFM 6.1 Area Velocity Flow Meter uses a submersible ultrasonic sensor measuring ...
Pulsar Measurement

Volumetric flow rate: 0 m³/s - 0 m³/s
Process temperature: -23 °C - 60 °C
Process pressure: 0 psi - 10 psi
Gaining flow measurement inside a pipe can sometimes be tricky. The DFM 6.1 Doppler Flow Meter works as a non-contacting, clamp-on flow meter to offer ...
Pulsar Measurement

Process temperature: -15 °C - 80 °C
... portable area velocity meter that measures flow using a submersible ultrasonic sensor. The unit is designed for flow surveys in open channels, partially-full sewer pipes, and surcharged ...
Pulsar Measurement

Process temperature: -25 °C - 120 °C
The OPTIFLUX 1300 is an electromagnetic flowmeter (EMF) with lightweight wafer-style design. The meter is an economical solution for applications with conductive liquids (≥ 5 μS/cm) and higher solid content ...
KROHNE Messtechnik

The OPTIFLUX 2300 is an electromagnetic flowmeter (EMF) for all demanding applications with water and wastewater. The high-end meter is particularly suitable for applications requiring ...
KROHNE Messtechnik

... is an electromagnetic flowmeter (EMF) with a patented, capacitive level measurement for use in partially filled pipes (up to DN1600 / 64”). The meter is the ideal solution for flow measurement ...
KROHNE Messtechnik

Volumetric flow rate: 90 us gal/min - 188.4 us gal/min
Process temperature: -20 °C - 60 °C
Process pressure: 150, 300 psi
... Electromagnetic Flanged Flow Meter An advanced, leading edge mag meter - the Ultra Mag flow meter sets a new standard for performance, ease-of-use, ...

Volumetric flow rate: 0.4 l/h - 1,000 l/h
Process temperature: 0 °C - 60 °C
Precision: 2, 1.6 %
New-Flow offers a large variety of products for measurement and control of temperature, pressure, flow, level, and valve. Case Material: SS316 Body Material: PVC, CPVC Float Material: SS316

The SeFlow 400 is Sewerin’s single channel portable flowmeter for applications in the municipal water and wastewater sector offering long term stable and precise bidirectional flow measurements ...

Process temperature: -20 °C - 70 °C
... as in low flow level circumstances -IoT-ready with global 4G connectivity for highest availability and digital services Hybrid Flow Measurement NivuFlow 7550 is a hybrid measurement system ...
NIVUS GmbH

Process temperature: -20 °C - 70 °C
... ambient conditions. The large graphic display permits quick and easy commissioning of the flow meter system. Due to the modular construction of our radar flow meter ...
NIVUS GmbH

High Accurate Flow Meter + Energy Saving Capabilities for Pump Stations NIVUS has for decades operated in the field of water and wastewater and feels responsible for protecting the ...
NIVUS GmbH

Volumetric flow rate: 1.6 m³/h - 3,125 m³/h
Process temperature: -40 °C - 70 °C
Process pressure: 1 bar - 10 bar
The working principle of the electromagnetic flow meter is based on the Faraday law of electromagnetic induction. When the conducting liquid flows in the orthogonal direction of the magnetic ...

Process temperature: 0 °F - 248 °F
Process pressure: 0 psi - 150 psi
Precision: 2 %
... measuring accuracy of +0.20% of flow + 1 mm/s and a flow rate range of 300:1, it enables high accuracy especially in the lower part of the measuring range. Flexible in use. The ModMAG® M3000 is particularly ...

Process temperature: -40 °C - 100 °C
... for many flow metering applications found in the potable water distribution sector and adjacent industries. The FLUXUS F501 offers a precise bi-directional flow measurement over a wide turndown ratio ...
FLEXIM Flexible Industriemesstechnik GmbH

Mass flow rate: 0 kg/h - 800,000 kg/h
Process temperature: -200 °C - 350 °C
Process pressure: 0 bar - 250 bar
Mass flow meter developed by HOLYKELL is a Coriolis mass flow meter. Based on the thermal principle, it can directly output mass flow. Therefore, it ...
Holykell

Process temperature: -30 °C - 160 °C
Precision: 1 %
Repeatibility: 0.2 %
Clamp On Ultrasonic Flow Meter is a non-contact type clamp-on flowmeter, which can not only measure the flow of large pipe diameter medium, but also can be used for the measurement of ...
Holykell

Volumetric flow rate: 0.1 m³/h - 381,703.5 m³/h
Process temperature: -10 °C - 60 °C
Process pressure: 0 bar - 250 bar
Electromagnetic Flow meter consisted of 4800-type flow sensor and 4800-type smart converter 4800-E Sanitary type supporting. It applies to measure (is fit for the measurement of ) the ...
Holykell

Volumetric flow rate: 150 l/h
Process temperature: 0 °C - 70 °C
Process pressure: 0 bar - 10 bar
... variable area Flow range for liquids up to 150 l/h Flow range for gaseous fluids up to 80 Nl/min. Process connection square; lateral, frontal ¼" or 3/8" Gas Temperature 70°C max Pressure up to 10 ...

Process temperature: -30 °C - 70 °C
... new AI.ERadar Fseries radar gauge is suitable for the measurement of 3 variables: level, water surface speed and consequent flow measurement. It is available in 3 versions according to the depth of the channel on which ...
ASIT ITALIA

Process temperature: -20 °C - 90 °C
Precision: 0.3 %
... .4FPC ULTRASONIC FLOW METER Processor control unit and flow rate level converter including display Ultrasonic level sensor included Kit to be combined with a parshall model AI.FPC in ...
ASIT ITALIA

Process temperature: -20 °C - 90 °C
Precision: 0.3 %
ULTRASONIC FLOW METER AI.4FPC-SS Processor control unit and flow rate level converter including display Ultrasonic level sensor included Kit to be combined with a parshall model AI.FPC-SS ...
ASIT ITALIA

Process temperature: -35 °C - 60 °C
Precision: 1 %
NON-CONTACT FLOW MEASUREMENT FOR WASTEWATER TREATMENT PLANTS, SEWERS AND INDUSTRIAL WATER CHANNELS The SQ-R measures continuously and contact-free the flow rate of effluent channels, ...
SOMMER Messtechnik GmbH

Process temperature: -40 °C - 80 °C
Process pressure: 0 bar - 1 bar
Precision: 2 %
... interfaces: RS-485, SDI-12, Modbus, analog, pulse VERSIONS PQ with flow velocity sensor and pressure probe PQ with flow velocity sensor and contact-free radar sensor PV with flow ...
SOMMER Messtechnik GmbH

Process temperature: -35 °C - 60 °C
... 30 Niro - same as with the RQ-30 - a continuous measurement of the discharge of open rivers and channels is determined. A high quality stainless-steel housing allows the usage even in aggressive waters and wastewater, ...
SOMMER Messtechnik GmbH

Volumetric flow rate: 0.9 m³/h - 6,627 m³/h
... ultrasonic level transmitter - Level transmitter can be used for all flume types - Displaying of flow measurement and average or total flow - Certification of measurement Applications - ...

Process temperature: -20 °C - 60 °C
... CHANNEL FLOW METERS. THESE COMES WITH ULTRASOUND OR HYDROSTATIC SENSORS FOR OPEN CHANNELS AND PARTIALLY FILLED PIPES. THE CURRENT GENERATION OF OPEN CHANNEL FLOW METERS ...
MJK Automation

Categories : Commonly Used Industrial Equipment/Parts, Electromagnetic Flowmeters, Flow Measurements Products WaterMaster is the ultimate solution for flow measurement and management in sectors as ...

Volumetric flow rate: 0 m³/h - 1,130 m³/h
Process temperature: -20 °C - 180 °C
Process pressure: 40 bar
... with a simple menu driven operation/programming (e.g. measuring range, pulse rate, low flow cut off). For example the flow volume, device status, limit values, flow direction, empty pipe ...

Process temperature: -40 °C - 300 °C
Process pressure: 16 bar - 420 bar
LTD Series General Electron Flowmeter (hereafter call flowmeter), is a precise flowmeter to measure the flow of liquid in the tube. This flowmeter is a patent right product, ...

... This generated voltage is changed depending on flow rate (Q), flow velocity (v), geometric correction factor also known as body coefficient (k), magnitude of magnetic field (B) and inner diameter of flowmeter ...

... rechargeable battery). For projects where a permanent flowmeter is not required or to temporarily replace installed flow transmitters. Ideal for tough flow applications (sewage, treated ...

Process temperature: -10 °C - 120 °C
Process pressure: 0.6 MPa - 4 MPa
Precision: 0.5 %
... coil, the following electromotive E is generated in proportion to flow speed v: Where: E-Induced electromotive force K-Meter constant B-Magnetic induction density V-Average flow ...
Supmea Automation

Volumetric flow rate: 500 m³/h
Process temperature: 55 °C
Process pressure: 16 bar
... operated by convertor, you can see the instantaneous flow, cumulative flow, output pulse, analog current and other signals for the measurement and control of fluid flow. PMF series electromagnetic ...

Process temperature: -40 °C - 60 °C
... measure open-channel flow. The sensor has advanced technology to measure velocity with a laser beam at single or multiple points below the surface of the wastewater stream. The LaserFlow is ideal ...
Teledyne Isco

Volumetric flow rate: 0 ft³/s - 16 ft³/s
Process temperature: -40 °C - 80 °C
Precision: 1 %
... and also the clear, user-friendly menu selections make flow meter more simple and convenient to use.Daily, monthly and yearly totalized flow. Parallel operation of positive, negative ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining